EEWORLDEEWORLDEEWORLD

Part Number

Search

GSC25D

Description
Linear and switching power supply 25w +5.1/+24/-12v
CategoryPower/power management   
File Size195KB,2 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

GSC25D Online Shopping

Suppliers Part Number Price MOQ In stock  
GSC25D - - View Buy Now

GSC25D Overview

Linear and switching power supply 25w +5.1/+24/-12v

GSC25D Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryLinear vs. Switching Power Supplies
RoHSno
productSwitching
Commercial/MedicalCommercial
Output power rating13 W
Input voltage90 VAC to 264 VAC
Number of outputs3
Output voltage (channel 1)5.1 V
Output current (channel 1)2.5 A
Output voltage (channel 2)24 V
Output current (channel 2)1 A
Output voltage (channel 3)- 12 V
Output current (channel 3)0.2 A
Installation styleChassis
size107.95 mm L x 63.5 mm W x 21.84 mm H
open frame/closedOpen Frame
Output typeTriple Outpu
series connectionGSC
GSC25 Commercial/GSM25 Medical
25 Watt Global Performance SWitcherS
GLOBAL PERFORMANCE SWITCHERS
Features:
• Industry’s smallest 25 W switcher
• 2.50 x 4.25 x 0.86”
• Conducted EMI exceeds FCC Class B and
CISPR 22 Class B (Commercial models) and
CISPR 11 Class B (Medical models)
• Overvoltage protection standard
• Commercial Approved to UL1950,
CSA-C22.2 No.950, EN60950
• Medical Approved to UL2601-1, IEC60601-1
EN60601-1 and CSA-C22.2 No. 601-1
• RoHS Compliant (G suffix)
marked to LVD
DC Power Supplies
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at minimum 120 Vac, 60 Hz with full rated output
load is 0.6 A.
Hold-up Time
15 ms minimum from loss of ac input at full load, nominal line (120 Vac).
Output Power
Normal continuous output power is 25 W, 28 W peak for 60 sec. maximum
duration, 10% duty cycle. Factory set to begin power limiting at approxi-
mately 30 W.
Output Regulation
Regulation from initial setpoint measured by changing load from 5% load to
50% load or 50% load to full load in either direction. Initial setpoint tolerance
is measured at 50% load. A minimum load of 5% of the output current on the
+5.1 V output (125 mA) is required to maintain proper regulation.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
scope probe directly across output terminals of the power supply with load
terminated with 0.1 uF capacitor.
Transient Response
Main output: 750 μs typical response time for return to within 0.5% of final
value for a 50% load step within the regulation limits of minimum and maxi-
mum load, ∆l/∆t <0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut-
down overshoot less than 2%.
Overvoltage Protection
Built in with firing point set per ratings table. OVP firing reduces voltage to
less than 50% of nominal voltage in 50 ms.
Voltage Adjustment
Factory set with fixed resistors to maximize reliability.
Efficiency
70% minimum at full rated load, nominal input voltage.
Input Protection
Internal ac fuse provided on all units.
Inrush Current
Inrush is limited by internal thermistor. The inrush at 230 Vac, averaged over the
first ac half-cycle under cold start conditions will not exceed 32 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output current
and total output power by 2.5% per °C between 50 - 70°C. See Environmental and
Packaging Specifications on next page.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions GSC25
Conducted Emissions GSM25
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
Commercial Safety:
Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all GSC
models are in conformity with the applicable requirements of EN60950 following
the provisions of the Low Voltage Directive 73/23/EEC. All GSC models are ap-
proved to UL1950, CSA-C22.2 No.950, EN60950.
GSM25 Medical Model Earth Leakage Current
Leakage current measured in the Gnd wire connection when measured per
UL2601-1 or IEC60601-1 is as follows:
Model
GSM25
GSM25
Normal
Leakage
50 μA
94 μA
Fault
Leakage
78 μA
150 μA
Test
Voltage
132 Vca/60 Hz
264 Vca/50 Hz
Test
Method
UL2601-1
IEC60601-1
Medical Safety
Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all
GSM models are in conformity with the applicable requirements of UL2601-1
Patient Care Equipment, CSA-C22.2 No.601.1, IEC60601-1, EN 60601-1.
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated

GSC25D Related Products

GSC25D GSM25BG GSC25B GSM25A GSM25D
Description Linear and switching power supply 25w +5.1/+24/-12v Linear and switching power supply 25w +5.1/+15/-15v Linear and switching power supply 25w +5.1/+15/-15v Linear and switching power supply 25w +5.1/+12/-12v Linear and switching power supply 25w +5.1/+24/-12v
Maker All Sensors All Sensors All Sensors All Sensors All Sensors
Product Category Linear vs. Switching Power Supplies Linear vs. Switching Power Supplies Linear vs. Switching Power Supplies Linear vs. Switching Power Supplies Linear vs. Switching Power Supplies
RoHS no yes no no no
product Switching Switching Switching Switching Switching
Commercial/Medical Commercial Medical Commercial Medical Medical
Output power rating 13 W 13 W 13 W 13 W 13 W
Input voltage 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC 90 VAC to 264 VAC
Number of outputs 3 3 3 3 3
Output voltage (channel 1) 5.1 V 5 V 5 V 5.1 V 5.1 V
Output current (channel 1) 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A
Output voltage (channel 2) 24 V 15 V 15 V 12 V 24 V
Output current (channel 2) 1 A 1.5 A 1.5 A 1.5 A 1 A
Output voltage (channel 3) - 12 V - 15 V - 15 V - 12 V - 12 V
Output current (channel 3) 0.2 A 0.2 A 0.2 A 0.2 A 0.2 A
Installation style Chassis Chassis Chassis Chassis Chassis
open frame/closed Open Frame Open Frame Open Frame Open Frame Open Frame
Output type Triple Outpu Triple Outpu Triple Outpu Triple Outpu Triple Outpu
series connection GSC GSM GSC GSM GSM
size 107.95 mm L x 63.5 mm W x 21.84 mm H - 107.95 mm L x 63.5 mm W x 21.84 mm H 107.95 mm L x 63.5 mm W x 21.84 mm H 107.95 mm L x 63.5 mm W x 21.84 mm H
A brief summary of MP3 and MP4 failures
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i] I simply summarize MP(N) faults as: "can't be turned on and can't be connected, can be turned on and can't be connected", and fa...
baxay Mobile and portable
How to use the same timer of msp430g2231 for PWM and analog serial port reception
How to use the same timer of msp430g2231 for PWM and analog serial port reception...
wanyong19860402 Microcontroller MCU
EEWORLD University Hall--NI Bridge Structural Health Monitoring System Demonstration
NI Bridge Structural Health Monitoring System Demonstration : https://training.eeworld.com.cn/course/1927...
chenyy Industrial Control Electronics
EVC simulator problem
After installing EVC SP4 on my machine, I can connect to the development board. Now I want to create a virtual environment to try it out, but I found that only one can connect to it, which is STANDARD...
tanghoul Embedded System
Thanks!!! Friends who participated in the "bug hunting operation"!
[align=center][size=5][b]Thanks!!! Friends who participated in the "bug hunting operation"! [/b][/size][/align] [size=4] [/size] [size=4] The "bug hunting operation" has just been carried out for a we...
tiankai001 Download Centre
I have a problem with the communication between the ARM board and the PC. Can any experts take a look?
I am working on communication between ARM board and PC. The PC is Windows 7 system, and ARM is running Linux 2.6. I use serial port and HyperTerminal to operate. ARM's IP is 192.168.1.6, and PC's IP i...
kevincoxee ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1199  1197  2620  1447  1776  25  53  30  36  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号