The ‘CH’ range of Modular Fuseholders may be used in conjunction with Class gR and aR High-Speed fuses,
offering a touch-safe design with no exposed contacts, according to the following application tables:
CHM Series (10x38)
High
Speed
Fuse
FWA-5A10F
FWA-10A10F
FWA-15A10F
FWA-20A10F
FWA-25A10F
FWA-30A10F
-
-
Maximum
Continuous
Fuse Current
(amps)
5
10
14
18
20
24
-
-
High
Speed
Fuse
FWC-6A10F
FWC-8A10F
FWC-10A10F
FWC-12A10F
FWC-16A10F
FWC-20A10F
FWC-25A10F
FWC-32A10F
Maximum
Continuous
Fuse Current
(amps)
6
8
10
12
15
16
19
21
CH22 Series (22x58)
High
Speed
Fuse
FWP-20A22F
FWP-25A22F
FWP-32A22F
FWP-40A22F
FWP-50A22F
FWP-63A22F
FWP-80A22F
FWP-100A22F
Maximum
High
Continuous
Speed
Fuse Current
Fuse
(amps)
5
FWP-32A14F
10
FWP-40A14F
14
FWP-50A14F
18
-
21
-
22
-
Maximum
Continuous
Fuse Current
(amps)
20
25
32
40
50
58
66
78
Maximum
Continuous
Current
(amps)
27
32
38
-
-
-
CH14 Series (14x51)
High
Speed
Fuse
FWX-5A14F
FWX-10A14F
FWX-15A14F
FWX-20A14F
FWX-25A14F
FWX-30A14F
Maximum
Continuous
Fuse Current
(amps)
5
10
15
20
24
27
High
Speed
Fuse
FWH-5A14F
FWH-10A14F
FWH-15A14F
FWH-20A14F
FWH-25A14F
FWH-30A14F
Maximum
Continuous
Fuse Current
(amps)
5
10
14
18
21
22
High
Speed
Fuse
FWP-5A14F
FWP-10A14F
FWP-15A14F
FWP-20A14F
FWP-25A14F
FWP-30A14F
Please contact Cooper Bussmann Application Engineering for more information regarding High-Speed fuse application.
Accessories for use with the new CH Series of Modular Fuseholders
Accessory
Multi-Phase Connection Links
For Use with Fuse Holders
Part Number
AL-D
CH810-HP
CH14-HP
C08NL
C10NL, NNB
NNB-R
C14NL
C22NL
CH14MS-1D
CH14MS-3D
No. of
Poles
-
-
-
-
-
-
-
-
1
3
Box Quantity
12
12
CH08, CHM, CHCC, AND CH14 Series
CH08, CHM,& CHCC Series
Multi-Phase Handle Pins
CH14 Series
CH08 Series
CHM Series
Neutral Links
CHCC Series
CH14 Series
CH22 Series
CH141 Series
Operated-Fuse Micro-Switches
CH143 Series
Multi-Phase
Connection Links
Multi-Phase
Handle Pins
10
5
2
Neutral Links
Operated-Fuse
Micro-Switches
6-24-04
SB04179
Form No. GMF
Page 2 of 4
Data Sheet: 2143
Bussmann
®
Global Modular Fuseholders
Dimensional Data
(all dimensions mm )
[inch]
Manual Multi-phase Construction
(10x38 & 14x51mm )
Additional poles can be added by using the accessories shown on page 2 of this data sheet.
The following components are required for each additional pole, up to a maximum of 4-poles.
Part Number
AL-D
CH810-HP
CH14-HP
Description
Multi-phase Connection Link
8x32 & 10x38 Handle Pin
14x51mm Handle Pin
Number Required
2
1
1
6-24-04
SB04179
Form No. GMF
Page 3 of 4
Data Sheet: 2143
Bussmann
®
Global Modular Fuseholders
14x51mm Dimensional Data
(all dimensions mm )
[inch]
22x58mm Dimensional Data
(all dimensions mm )
[inch]
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
6-24-04
SB04179
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
Actually, you are very familiar with the usage of electrolytic tantalum capacitors and ceramic capacitors. You have only used them more in bypass filtering and rarely in other circuits. Can anyone giv...
I have always wanted to make an engraving machine. Since I can't afford a big one, I decided to make a small laser engraving machine! The first step was to make the structure. After 2 weeks, I finally...
Seeing that the prizes for this EEWORLD DIY are quite generous, I just took this opportunity to share the DIY portable measuring instrument and see if I can win a RIGOL oscilloscope. I also hope that ...
1 Introduction
The multifunctional monitor is a commonly used clinical medical device. It can display the patient's electrocardiogram (ECG), respiration (RESP), blood oxygen saturation (SP...[Details]
Medical and industrial applications often require isolation voltages of 2500Vac or higher for patient and equipment operator safety. The isolation barrier must not only transmit power to the sensin...[Details]
Sensors have made inroads into automotive, medical, industrial and aerospace applications. But you may not see anything changing yet. Growing demands for safety, convenience, entertainment and efficie...[Details]
Maximize instrument utilization and reduce
test times
Increasing the throughput of automated test systems can improve efficiency. Using off-the-shelf tools (COTS) such as multicore proc...[Details]
Controller Area Network (CAN) is a type of fieldbus. It is a serial communication network that effectively supports distributed control or real-time control and is recognized as one of the most pro...[Details]
The overcurrent and overheating coordinated protection technology implemented by polymer positive temperature coefficient devices (PPTC) can protect motors, controllers and electronic components in...[Details]
1 Introduction
The intelligent meter reading system is a system that reads the data of multiple user meters in a centralized manner through the transmission media by the master station. It...[Details]
This article first briefly introduces the working principles of current mode and voltage mode and their respective advantages and disadvantages; then discusses the ideal voltage mode using output c...[Details]
introduction
Controller Area Network (CAN) is a bus standard proposed by Bosch of Germany to solve the information communication between automotive electronic control units. With its excel...[Details]
Today's mobile phone production testing faces an increasingly complex environment, with challenges of multiple frequency bands and multiple standards, pressure on production test speed, and pres...[Details]
Preface
In the analog era, due to the unchanged specifications and relatively simple device connections, as well as users' low requirements for image quality, the relatively simple environment...[Details]
Multiple Input and Multiple Output (MIMO) technology is arguably the next most important development in wireless communication technology since the advent of digital communications. Many new wir...[Details]
The microwave multifunctional therapeutic device uses microwave radiation for heating treatment, which can achieve the effects of sterilization and blood circulation. Using microwaves to directly c...[Details]
Abstract: By controlling the supply voltage of the radio frequency (RF) power amplifier (PA) in a CDMA/WCDMA cellular phone, the PA efficiency can be improved, heat generation can be reduced, and t...[Details]
The rapid growth of consumer video applications, from portable media players and cell phones to video game consoles, requires a multitude of different interfaces and adapters to enable users to tra...[Details]