PCB Relay
G2RL
A Power Relay with Various Models
• High-sensitivity (250 mW) and High-capacity (16 A) versions.
• Designed for cooking and HVAC controls: blower motor,
damper, active air purification, duct flow boost fans, etc.
• Conforms to VDE (EN61810-1). UL recognized/ CSA certiified
• Meets EN60335-1 requirements for household products.
• Clearance and creepage distance: 10 mm/10 mm.
• Tracking resistance: CTI>250
• Coil Insulation system: Class F.
• RoHS Compliant
Ordering Information
Classification
General-purpose
High-capacity
High-sensitivity
Enclosure
ratings
Flux protection
Fully sealed
Flux protection
Fully sealed
Flux protection
Contact form
SPST-NO
G2RL-1A
G2RL-1A4
G2RL-1A-E
G2RL-1A4-E
G2RL-1A-H
SPDT
G2RL-1
G2RL-14
G2RL-1-E
G2RL-14-E
G2RL-1-H
DPST-NO
G2RL-2A
G2RL-2A4
---
---
---
DPDT
G2RL-2
G2RL-24
---
---
---
Note:
When
ordering, add the rated coil
voltage
to the model number.
Example: G2RL-1A DC12
Rated coil
voltage
Model Number Legend
G2RL-@@@-@
1
2
3
4
1. Number of Poles
1:
1 pole
2:
2 poles
2. Contact Form
None:
@PDT
A:
@PST-NO
3. Enclosure Ratings
None: Flux protection
4:
Fully sealed
4. Classification
None: General purpose
E:
High capacity (1 pole)
H:
High sensitivity (1 pole)
Specifications
■
Coils Ratings for General-purpose and High-capacity Models
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
5 VDC
80.0 mA
62.5
Ω
12 VDC
33.3 mA
360
Ω
24 VDC
16.7 mA
1,440
Ω
48 VDC
8.96 mA
5,358
Ω
70% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Approx. 400 mW
Approx. 430 mW
Note:
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
PCB Relay
G2RL
203
■
Coils Ratings for High-sensitivity Models
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
5 VDC
50.0 mA
100
Ω
75% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Approx. 250 mW
12 VDC
20.8 mA
576
Ω
24 VDC
10.42 mA
2,304
Ω
Note:
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
■
Contact Ratings
Item
Number of poles
Contact material
Load
Rated load
1 pole
Ag Alloy (Cd free)
Resistive load (cosφ=1)
12 A at 250 VAC
12 A at 24 VDC
(See note.)
12 A (See note.)
440 VAC, 300 VDC
12 A
3,000 VA (4,000 VA)
8A
2,000 VA
16 A
4,000 VA
10 A
2,500 VA
8 A at 250 VAC
8 A at 30 VDC
(See note.)
8 A (70°C)/5 A (85°C)
(See note.)
16 A at 250 VAC
16 A at 30 VDC
(See note.)
16 A (See note.)
10 A at 250 VAC
10 A at 24 VDC
(See note.)
10 A (See note.)
General-purpose Models
2 poles
High-capacity Models
1 pole
High-sensitivity Models
1 pole
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Note:
Contact your OMRON representative for the ratings on fully sealed models.
■
Characteristics
Item
Number of poles
Contact resistance
Operate (set) time
Release (reset) time
General-purpose
(High-capacity) Models
1 pole
100 mΩ max.
15 ms max.
5 ms max.
General-purpose Models
2 pole
High-sensitivity Models
1 pole
Max. operating frequency
Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load
Insulation resistance
Dielectric strength
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts
of same polarity
5,000 VAC, 1 min between coil and
contacts
2,500 VAC, 1 min between contacts of
different polarity
1,000 VAC, 1 min between contacts of
same polarity
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts
of same polarity
Impulse withstand voltage
10 kV (1.2×50
μs)
between coil and contact
Vibration resistance
Shock resistance
Endurance (Mechanical)
Ambient temperature
Ambient humidity
Weight
Destruction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction:1,000 m/s
2
(approx. 100 G)
Malfunction:100 m/s
2
(approx. 10 G)
20,000,000 operations (at 18,000 operations/hr)
Operating:–40°C to 85°C (with no icing)
Storage:–40°C to 85°C (with no icing)
5% to 85%
Approx. 12 g
Note:
Values in the above table are the initial values.
204
PCB Relay
G2RL
■
Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Model
G2RL-1A
G2RL-1
G2RL-1A-E
G2RL-1-E
G2RL-1A-H
G2RL-1-H
G2RL-2A
G2RL-2
Contact form
SPST-NO
SPDT
SPST-NO
SPDT
SPST-NO
SPDT
DPST-NO
DPDT
3 to 48 VDC
5 to 24 VDC
3 to 48 VDC
Coil ratings
3 to 48 VDC
Contact ratings
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
Number of test operations
100,000
50,000
100,000
50,000
50,000
100,000
Note:
Consult Omron for additional UL / CSA ratings
VDE (EN61810-1) (License No. 119650)
Model
G2RL-1(A)
1 pole
Contact form
Coil ratings
5, 12, 18, 22, 24, 48 VDC
Contact ratings
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15:
3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13:
G2RL-1(A)-H
G2RL-2(A)
1 pole
2 poles
5, 9, 12, 24 VDC
5, 12, 18, 22, 24, 48 VDC
2.5 A at 24 VDC (NO), 50 ms
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC (L/R=0 ms)
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15:
1.5 A at 240 VAC
DC13:
2 A at 30 VDC, 50 ms
G2RL-1(A)-E
1 pole
5, 12, 18, 22, 24, 48 VDC
Note:
To achieve approved life cycles on sealed models, the relay should be vented by removing the “knock off vent nib” on top of relay case after
the soldering/washing process.
Electrical Life Data
G2RL-1-E
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC
8 A at 250 VAC (cosφ=0.4)
8 A at 30 VDC (L/R=7 ms)
G2RL-1
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC
5 A at 250 VAC (cosφ=0.4)
5 A at 30 VDC (L/R=7 ms)
G2RL-1-H
G2RL-2
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC
8 A at 250 VAC (cosφ=1)
8 A at 30 VDC
30,000 operations min.
30,000 operations min.
200,000 operation min. (normally open side operation)
10,000 operation min. (normally open side operation)
50,000 operations min.
30,000 operations min.
150,000 operation min. (normally open side operation)
20,000 operation min. (normally open side operation)
100,000 operations min.
50,000 operations min.
30,000 operations min.
30,000 operations min.
Note: 1.
The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
2.
In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the “knock off vent
nib” on top of the relay case after the soldering/washing process.
3.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
information for the electrical endurance under your test conditions.
PCB Relay
G2RL
205
Engineering Data
■
Maximum Switching Capacity
G2RL-1A, G2RL-1
Switching current (A)
Switching current (A)
G2RL-1A-E, G2RL-1-E
AC resistive load
AC resistive load
DC resistive
load
DC resistive
load
Switching
voltage
(V)
Switching
voltage
(V)
G2RL-1A-H, G2RL-1-H
Switching current (A)
Switching current (A)
G2RL-2A, G2RL-2
AC resistive load
AC resistive load
DC resistive
load
DC resistive
load
Switching
voltage
(V)
Switching
voltage
(V)
■
Ambient Temperature
vs Rated Carry Current
Rated carry current (A)
G2RL-1A-E, G2RL-1-E
■
Ambient Temperature
vs Maximum Coil Voltage
Maximum coil
voltage
(%)
G2RL-1A, G2RL-1
G2RL-1A-H, G2RL-1-H
G2RL-2A, G2RL-2
85
Ambient temperature (°C)
Ambient temperature (°C)
Note:
The maximum coil
voltage
refers to the maximum
value
in a
varying
range of operating power
voltage,
not a continuous
voltage.
Note:
Contact your OMRON representative for the data on fully sealed models.
206
PCB Relay
G2RL
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G2RL-1A(-H), G2RL-1A4
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.8
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
3
7.5
5
4
(2.3)
Mounting Holes
(Bottom View)
3.5
Four, 1.3±0.1 dia.
holes
(2.5)
* Indicates average dimensions.
20
G2RL-1(-H), G2RL-14
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.5
0.8
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
2
3
7.5
5
4
(2.3)
Mounting Holes
(Bottom View)
3.5 3.5
Five, 1.3±0.1 dia.
holes
(2.5)
* Indicates average dimensions.
20
G2RL-1A-E, G2RL-1A4-E
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.8
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
8
3
4
7.5
6
5
(2.3)
Mounting Holes
(Bottom View)
5
Six, 1.3±0.1 dia.
holes
(2.5)
* Indicates average dimensions.
20
G2RL-1-E, G2RL-14-E
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.5
0.8
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
2
3
4
7.5
8
7
6
5
(2.3)
* Indicates average dimensions.
Mounting Holes
(Bottom View)
5
5
Eight, 1.3±0.1 dia.
holes
(2.5)
20
G2RL-2A, G2RL-2A4
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.8
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
8
3
4
7.5
6 5
(2.3)
Mounting Holes
(Bottom View)
5
Six, 1.3±0.1 dia.
holes
(2.5)
* Indicates average dimensions.
20
G2RL-2, G2RL-24
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
0.5
0.5
0.5
0.5
12.7 max.
(12.5)*
Terminal Arrangement/
Internal Connection
(Bottom View)
1
2
3
4
7.5
8
7
6
5
(2.3)
Mounting Holes
(Bottom View)
5
5
Eight, 1.3±0.1 dia.
holes
(2.5)
0.8
* Indicates average dimensions.
20
PCB Relay
G2RL
207