EEWORLDEEWORLDEEWORLD

Part Number

Search

L21-B1-26-410-241-K3

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L21-B1-26-410-241-K3 Overview

Magnetic Circuit Breaker,

L21-B1-26-410-241-K3 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7347466780
Reach Compliance Codecompliant
Country Of OriginMexico
YTEOL7.9
Actuator typeROCKER
Other featuresSTANDARDS: MIL-PRF-55629, MIL-STD-202
body width19.05 mm
body height49.4 mm
Body length or diameter92.58 mm
circuit functionSERIES TRIP
Circuit protection typeMAGNETIC CIRCUIT BREAKER
Environmental characteristicsMOISTURE RESISTANT
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Rated breaking capacity5000 A
Rated current1 A
Rated voltage (AC)120 V
GuidelineEN; TUV; UL
surface mountNO
Terminal shapeSCREW
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
Discussion on how to prevent electricity theft by centralized meter reading
Regarding the problem of electricity theft, it seems important to prevent it through meter reading. I will discuss this in another thread. Personally, I think the biggest difficulty in preventing elec...
老夫子 Industrial Control Electronics
How to deal with the idle IO ports of the microcontroller?
I would like to ask the experts a question. How to deal with the idle IO ports of the microcontroller? I have seen various opinions on the Internet. Some say to set it as input and connect a resistor ...
cy15880085090 MCU
Huawei Hardware Engineer's Manual
See nearby...
luohaisong Download Centre
Help: How to use two power supplies to drive the same load
I have two power supplies, with output voltages of 24V and 15V respectively. How can I make these two power supplies power a 5 ohm load at the same time?...
wuhx Power technology
LED industry is booming and PCB industry is welcoming new opportunities
With the World Expo, Asian Games and the promotion of the "Ten Cities, Ten Thousand Lights" policy, the demand for LED market has increased greatly. According to the person in charge of the Guangdong ...
探路者 PCB Design
I would like to ask for advice on the program of using a microcontroller to drive a relay to light a light bulb.
There should be no problem with the program. It may be a problem with my simulation circuit. When running, it just won’t light up.Ask an expert to take a look.The code files and protues simulation fil...
jckimi 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2400  2081  1980  1896  850  49  42  40  39  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号