EEWORLDEEWORLDEEWORLD

Part Number

Search

TA35-CETRF200-CZM23

Description
Thermal Circuit Breaker, 2 Pole(s), 20A, 240VAC, 60VDC, Panel Mount,
CategoryCircuit protection    Circuit protection   
File Size1001KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

TA35-CETRF200-CZM23 Overview

Thermal Circuit Breaker, 2 Pole(s), 20A, 240VAC, 60VDC, Panel Mount,

TA35-CETRF200-CZM23 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1978478740
Reach Compliance Codenot_compliant
YTEOL9.2
Actuator typeROCKER
body width26 mm
body height43.9 mm
Body length or diameter39 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsIP40
Installation featuresPANEL MOUNT
Number of poles2
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size39mm x 26mm x 43.9mm
Rated breaking capacity2000 A
Rated current20 A
Rated voltage (AC)240 V
Rated voltage (DC)60 V
GuidelineCCC; CSA; CUL; GB; IEC; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, Rocker actuation, 2 pole
TA35 Rocker 2Pole
Description
-
-
-
-
-
-
-
-
-
-
-
Thermal circuit breaker
2-pole
Snap-in version
Positively trip-free release
Different rocker colours
High configurability
Wide current range
IEC 60934
UL 1077
CSA C22.2 235
GB 17701
Characteristics
-
-
-
-
-
Power tools
Industrial appliances
Equipment for construction
Cleaning equipment
Commercial and household kitchen appliances
Weblinks
Standards
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
240 V; 50/60 Hz
60 V
0.05 - 20 A
0.05...20 A: 2 kA, SC (C1) @ 240 VAC
from front side IP 40 acc. to IEC 60529
50 Hz: > 2.5 kV
Impulse 1.2/50
μs:
> 4 kV
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir, cos
φ
0.6:
50'000 switching cycles
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
Overload
Ambient temperature
Vibration Resistance
IEC: min. 40 trips
@ 6 x Ir, cos
φ
0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos
φ
0.75
-30 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
29.0 - 31.5 g
Shock Resistance
Tripping Type
Weight
Dimension
36
34
7.2
1.7
29
20.9
26
+0.2
0
+0.3
44.1
10.5
LINE
10.6
34
Panel 1.0 − 4.0 mm
L
21.3
33.8
2.3
11 6.1
23.5
26
6.3 x 0.8 mm
33.5
Circuit Breakers
+0.2
0
1
Detailed description of the two commonly used hexadecimal file formats for programming UCD3xxx series digital power controllers: X0 and Intel Hex
Introduction: Files with the suffix X0 are a type of hexadecimal file format, and the Intel Hex file format is also a commonly used hexadecimal file format. X0 is a common file format used by TI burni...
德州仪器 Analogue and Mixed Signal
Regarding the question of magnification, what do I need to write for the software part?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:36[/i] As the title says, I would like to ask for your guidance, what do I need to do with the software part?...
whr0101 Electronics Design Contest
Why does the stream interface driver CreateFile fail?
HANDLE handle=CreateFile(_T("TTT1:"),GENERIC_READ|GENERIC_WRITE,0, NULL,OPEN_EXISTING,0,NULL); ASSERT(handle); if (handle == INVALID_HANDLE_VALUE) // cannot open the drive {MessageBox(NULL,_T("CreateF...
micstar Embedded System
12.6 Afternoon Peking University: Best-selling author's large-scale technical lecture on embedded Linux driver development and career guidance [free]
Top-e Embedded Popularization Series of Activities: Embedded Linux Driver Development and Employment Guidance Large-scale Technical Lecture (Beijing Station) - Development experts and best-selling boo...
linaiwen Linux and Android
[Meet friends through disassembly] Disassembly of the electric bicycle drive
I recently got an electric bicycle driver. I've been looking at it and I've been itching to take it apart to see what's inside. When I saw the [url=https://bbs.eeworld.com.cn/thread-495209-1-1.html]fo...
bkn1860 Making friends through disassembly
Design (430/51/host computer software)
Design (430/51/host computer software) 1. Hardware related (mainly using msp430 and 51) control class, temperature acquisition class, serial communication class, heat meter class, card product class, ...
zmqi Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1428  1953  2471  1722  1419  29  40  50  35  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号