EEWORLDEEWORLDEEWORLD

Part Number

Search

4130-G211-K4M1-30A

Description
cir brkr thrm 30a 240vac 50vdc
CategoryCircuit protection   
File Size157KB,2 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet Parametric View All

4130-G211-K4M1-30A Online Shopping

Suppliers Part Number Price MOQ In stock  
4130-G211-K4M1-30A - - View Buy Now

4130-G211-K4M1-30A Overview

cir brkr thrm 30a 240vac 50vdc

4130-G211-K4M1-30A Parametric

Parameter NameAttribute value
Datasheets
4130-G2,4 Series
Standard Package1
CategoryCircuit Protecti
FamilyCircuit Breakers
Breaker TypeThermal
Current Rating30A
Voltage Rating - AC240V
Voltage Rating - DC50V
Number of Poles1
Actuator TypePush to Rese
Illuminati-
Illumination Voltage (Nominal)-
Mounting TypePanel Mou
High Performance Thermal Circuit Breaker 4130-...
Description
Single pole high performance thermal circuit breaker, with push-to-reset
tease free, trip-free snap action mechanism (R-type TO CBE to EN
60934). Designed for threadneck panel mounting and for applications
with a high fault current switching requirement.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, battery chargers, power supplies,
appliances, machinery, extra low voltage systems.
Ordering information
Type No.
4130
single pole thermal circuit breaker
Mounting
G2
M12x1, knurled nut (bulk shipped with 5 pcs plus)
G4
M12x1, hex nut and knurled nut (bulk shipped with 5 pcs plus)
Number of poles
1
single pole, thermally protected
Actuator configuration
1
black push button
Terminal design
K4
terminal M6x8
screw and washer bulk shipped
Characteristic curve
M1
medium delay
Current ratings
20... 80 A
4130 - G2
1
1 - K4 M1 - 20 A
ordering example
4130-...
Technical data
For further details please
Voltage rating
Current rating range
Typical life
AC 240 V: 20...70 A
DC 50 V:
20...80 A
Ambient temperature
Insulation co-ordination
(IEC 60664)
see chapter: Technical Information
AC 240 V; DC 50 V
20...80 A
100 operations at 2 x I
N
, inductive
500 operations at 2 x I
N
, resistive
500 operations at 2 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
(reinforced insulation in the mounting area)
2
Dielectric strength
operating area
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077)
Preferred types
Preferred types
4130-G211-K4M1-
4130-G411-K4M1-
Standard current ratings (A)
20
x
x
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
800 A
I
N
U
N
20...80 A
AC 240 V
1,000 A
20...60 A
AC 120 V
3,500 A
80 A
AC 120 V
2,000 A
20...50 A
DC 50 V
3,500 A
60...80 A
DC 50 V
2,000 A
operating area IP40
terminal area IP00
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 55 g
25
x
x
30
x
x
35
x
x
40
x
x
45
x
x
50
x
x
60
x
x
70
x
x
80
Standard current ratings and typical internal resistance values
Current
rating (A)
20
25
30
35
35
Internal
resistance (Ω)
< 0.02
< 0.02
< 0.02
< 0.02
< 0,02
Current
rating (A)
40
50
60
70
80
Internal
resistance (Ω)
< 0.01
< 0.01
< 0.01
< 0.01
< 0,01
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Approvals
Authority
VDE
UL
CSA
Standard
IEC/EN 60934
UL 1077
C22.2 No 235
Rated voltage
AC 240 V
DC 50 V
AC 240 V
DC 50 V
AC 240 V
DC 50 V
Current ratings
20 A…70 A
20 A…80 A
20 A…80 A
20 A…80 A
20 A…80 A
20 A…80 A
2015/16
www.e-t-a.de
2
- 97
Triple network integration, high-definition network cameras give your home a brand new look!
The pilot program for the integration of three networks has been approved, and the list of pilot cities will be announced soon. This cross-century initiative is getting closer and closer to us. The in...
kinham001 Industrial Control Electronics
【LaunchPad】Try MSP430g2211
Did you notice that there is a chip inside the 25 yuan board? I checked and it is called MSP430G2211. Is this thing useful?Try it, I wrote a program that is similar to the example program.But there wa...
ddllxxrr Microcontroller MCU
FPGA Implementation of Dual-Mode CORDIC Algorithm
FPGA Implementation of Dual-Mode CORDIC Algorithm pdf paper...
liwenqi FPGA/CPLD
Is there any overtime?
Is there any overtime?...
hinii23 Talking about work
For NPN tubes, the c and e poles of U(br)ceo are both N-type, so where does the reverse statement come from?
For NPN tubes, the c and e poles of Ubrceo are both N-type, so where does the reverse statement come from? Another question is, are U(br)ceo and Uceo the same thing?...
深圳小花 MCU
MCU simulation problem
I am now doing a MCU simulation. The input data is correct, but after a while of simulation, the digital tube display will show garbled characters. What could this be? How can I solve it? Please help ...
yeming Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 863  1658  2632  506  1655  18  34  53  11  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号