EEWORLDEEWORLDEEWORLD

Part Number

Search

20AYT6C

Description
Power line filter 20a stud grnd choke high performance
CategoryThe connector   
File Size451KB,3 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

20AYT6C Online Shopping

Suppliers Part Number Price MOQ In stock  
20AYT6C - - View Buy Now

20AYT6C Overview

Power line filter 20a stud grnd choke high performance

20AYT6C Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryPower line filter
RoHSyes
Voltage rating250 VAC
Current rating20 A
filter typePower Line
filterYes
Leakage current3.4 mA
EncapsulationBulk
series connectionA (20-60 Amp)
Entrance typePower Line
Corcom Product Guide
Catalog: 1654001
Issue Date: 08.2010
High Performance 3-phase RFI Filters for WYE Applications
A Series
UL Recognized
CSA Certified
VDE Approved
A Series
• For 3-phase, four wire, WYE Applications
• Filters each of the three lines plus the neutral and
ground line
• Both common mode and differential mode
suppression from 50kHz to 30MHz
• Effective for both balanced and unbalanced loads
• Ground choke included
• Optional end bell kits available to shield input and
output terminals
• AYP single stage for lower noise environments
• AYT dual stage provides highest performance
Specifications
Maximum leakage current, each Line to Ground:
@ 120 VAC 60 Hz:
1.4 mA
@ 250 VAC 50 Hz:
3.4 mA
Hipot rating (one minute):
Line to Ground:
Neutral to Ground:
Line to Neutral:
Rated Voltage (max):
Phase to Phase:
Phase to Neutral / Ground:
Operating Frequency:
Rated Current:
1500 VAC
1500 VAC
1450 VDC
440 VAC
250 VAC
50/60 Hz
20 to 60A
Ordering Information
45 AYT 6 C
Suffix
C – Ground Choke
Input / Output Style
6 – Threaded 1/4 – 20 bolt
Series designation
AYP – Single Stage
AYT – Dual Stage
Current Rating
20, 30, 45 or 60A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
√(85-Ta)/45
Electrical Schematics
AYP6C Models
LINE
A
B
C
N
LOAD
A
B
C
N
LINE
GND
LOAD
GND
98
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com

20AYT6C Related Products

20AYT6C 45AYT6C 30AYP6C 30AYT6C 45AYP6C 60AYP6C 60AYT6C
Description Power line filter 20a stud grnd choke high performance Power line filter 45a stud grnd choke high performance Power line filter 30a stud grnd choke low noise Power line filter 30a stud grnd choke high performance Power line filter 45a stud grnd choke low noise Power line filter 60a stud grnd choke low noise Power line filter 60a stud grnd choke high performance
Maker All Sensors All Sensors All Sensors All Sensors All Sensors All Sensors All Sensors
Product Category Power line filter Power line filter Power line filter Power line filter Power line filter Power line filter Power line filter
RoHS yes yes yes yes yes yes yes
Voltage rating 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
Current rating 20 A 45 A 30 A 30 A 45 A 60 A 60 A
filter type Power Line Power Line Power Line Power Line Power Line Power Line Power Line
filter Yes Yes Yes Yes Yes Yes Yes
Leakage current 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA
series connection A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp)
Entrance type Power Line Power Line Power Line Power Line Power Line Power Line Power Line
Encapsulation Bulk Bulk Bulk Bulk Bulk - Bulk
Opportunities facing my country's medical electronics industry
Innovative technology has been constantly changing human life. The development of the medical electronics industry can be said to be the best footnote to this statement: medical electronics has used e...
天天谈芯 Medical Electronics
Overcurrent protection method for DC circuit
Overcurrent protection method for DC circuit 2006-06-13 17:04:11Overcurrent protection method of DC circuit 450) {this.resized=true; this.width=450; this.alt='Click to view the original image';}; this...
youweixing Industrial Control Electronics
Liyuan ST Brand Group: STM32F746 new product first drop STM32 Nucleo set off the lowest price in the whole network
[align=left][/align] [align=left][size=3][font=微软雅黑]Friends in need can pay attention to it, [/font]same quality, different price: [/size][/align][align=left][size=3] [/size][/align][align=left][b][si...
eric_wang stm32/stm8
Seeking shaping circuit solution
I want to reshape a 10M sine wave signal. Does anyone have a better solution or chip?...
风中飞 Analog electronics
Some controversial PCB layout rules of thumb
I recently saw a blog post written by Zachariah Peterson in April 2020,The Great PCB Layout Rules of Thumb Debate Rages On [1] , which discussed some of the most controversial rules of thumb for desig...
btty038 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 54  2123  2577  544  888  2  43  52  11  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号