EEWORLDEEWORLDEEWORLD

Part Number

Search

30AYT6C

Description
Power line filter 30a stud grnd choke high performance
CategoryThe connector   
File Size451KB,3 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

30AYT6C Online Shopping

Suppliers Part Number Price MOQ In stock  
30AYT6C - - View Buy Now

30AYT6C Overview

Power line filter 30a stud grnd choke high performance

30AYT6C Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryPower line filter
RoHSyes
Voltage rating250 VAC
Current rating30 A
filter typePower Line
filterYes
Leakage current3.4 mA
EncapsulationBulk
series connectionA (20-60 Amp)
Entrance typePower Line
Corcom Product Guide
Catalog: 1654001
Issue Date: 08.2010
High Performance 3-phase RFI Filters for WYE Applications
A Series
UL Recognized
CSA Certified
VDE Approved
A Series
• For 3-phase, four wire, WYE Applications
• Filters each of the three lines plus the neutral and
ground line
• Both common mode and differential mode
suppression from 50kHz to 30MHz
• Effective for both balanced and unbalanced loads
• Ground choke included
• Optional end bell kits available to shield input and
output terminals
• AYP single stage for lower noise environments
• AYT dual stage provides highest performance
Specifications
Maximum leakage current, each Line to Ground:
@ 120 VAC 60 Hz:
1.4 mA
@ 250 VAC 50 Hz:
3.4 mA
Hipot rating (one minute):
Line to Ground:
Neutral to Ground:
Line to Neutral:
Rated Voltage (max):
Phase to Phase:
Phase to Neutral / Ground:
Operating Frequency:
Rated Current:
1500 VAC
1500 VAC
1450 VDC
440 VAC
250 VAC
50/60 Hz
20 to 60A
Ordering Information
45 AYT 6 C
Suffix
C – Ground Choke
Input / Output Style
6 – Threaded 1/4 – 20 bolt
Series designation
AYP – Single Stage
AYT – Dual Stage
Current Rating
20, 30, 45 or 60A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
√(85-Ta)/45
Electrical Schematics
AYP6C Models
LINE
A
B
C
N
LOAD
A
B
C
N
LINE
GND
LOAD
GND
98
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com

30AYT6C Related Products

30AYT6C 45AYT6C 20AYT6C 30AYP6C 45AYP6C 60AYP6C 60AYT6C
Description Power line filter 30a stud grnd choke high performance Power line filter 45a stud grnd choke high performance Power line filter 20a stud grnd choke high performance Power line filter 30a stud grnd choke low noise Power line filter 45a stud grnd choke low noise Power line filter 60a stud grnd choke low noise Power line filter 60a stud grnd choke high performance
Maker All Sensors All Sensors All Sensors All Sensors All Sensors All Sensors All Sensors
Product Category Power line filter Power line filter Power line filter Power line filter Power line filter Power line filter Power line filter
RoHS yes yes yes yes yes yes yes
Voltage rating 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
Current rating 30 A 45 A 20 A 30 A 45 A 60 A 60 A
filter type Power Line Power Line Power Line Power Line Power Line Power Line Power Line
filter Yes Yes Yes Yes Yes Yes Yes
Leakage current 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA 3.4 mA
series connection A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp) A (20-60 Amp)
Entrance type Power Line Power Line Power Line Power Line Power Line Power Line Power Line
Encapsulation Bulk Bulk Bulk Bulk Bulk - Bulk
Understanding GaN Device Thermal Analysis
Want to know how to assess the lifecycle of your GaN product? This blog post includes an instructional video to help you analyze and determine GaN thermal considerations in your product designs. Do yo...
alan000345 RF/Wirelessly
5. Control objects in previous “Control” competitions
1. Heater control In the "Water Temperature Control System (1997 C)" competition, the heater is powered by AC220V, and the heater (temperature) is controlled by relays or bidirectional thyristors. The...
sigma Electronics Design Contest
Dual-position drive linear servo motor triple dynamic synchronous control
A new dynamic synchronization control method is proposed for dual-position drive linear servo motors. By designing a robust controller , the acceleration and speed are simultaneously controlled by sta...
frozenviolet Industrial Control Electronics
Digital-analog hybrid
Digital-analog hybrid...
linda_xia Analog electronics
Share a four-axis solution using Nuvoton M452 (schematic diagram, source code)
Share a four-axis remote control using the Nuvoton M452 series Cortex-M4 MCU using the Nuvoton N79E814, and with Southern Silicon Valley 2.4GRF for wireless remote control [b] Has anyone played with t...
赵玉田 DIY/Open Source Hardware
About the problem of using LM3S811 ultrasonic distance measurement
I set it up to detect reception using an external interrupt, and then read the current capture value of the timer in the interrupt function of the external interrupt. But why is the capture value the ...
千里之外想你 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1480  2094  844  922  788  30  43  17  19  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号