Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
•
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
•
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
•
Terminals face the front when the cover is removed for
easy connection.
•
Switches with ground terminals have CE marking.
•
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read
Safety Precautions
on page 8 to 9 and
Safety Precautions for All Limit Switches.
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(4) Conduit/Ground Terminal
*
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
AC
Plunger
DC
AC
Roller plunger
DC
General
purpose
AC
Crossroller plunger
DC
AC
Roller arm lever
DC
One-way action roller
arm lever
AC
DC
AC
Sealed plunger
DC
Sealed roller plunger
Sealed
(Booted)
Sealed crossroller
plunger
Sealed roller arm lever
DC
One-way action
sealed roller arm lever
AC
DC
AC
AC
AC
Model
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
Approved
standards
UL
●
CSA
●
Model
ZV-Q-2
XV-Q-2
Approved
standards
UL
●
CSA
●
Model
ZV2-Q-2
XV2-Q-2
Approved
standards
UL
●
CSA
●
●
●
ZV-Q22-2
XV-Q22-2
●
●
ZV2-Q22-2
XV2-Q22-2
●
●
●
●
ZV-Q21-2
XV-Q21-2
●
●
ZV2-Q21-2
---
●
●
●
●
ZV-QA2-2
XV-QA2-2
●
●
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
---
●
●
●
●
---
---
●
●
●
●
ZV-N-2
XV-N-2
●
●
ZV2-N-2
XV2-N-2
●
●
●
●
●
●
●
●
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
●
●
●
●
●
●
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
●
●
●
●
●
●
●
●
ZV-NA277-2
---
●
●
ZV2-NA277-2
XV2-NA277-2
●
●
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
UL
CSA
CCC (CQC)
Standard
UL508
CSA C22.2 No.14
GB14048.5
File No.
E76675
LR45746
2003010303077623
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Resistive load
NC
ZE-@
ZV-@
ZV2-@
15
15
10
0.5
0.25
10
10
10
10
3
3
3
3
3
1.5
NO
Lamp load
NC
3
2.5
1.5
0.5
0.25
1.5
1.5
1.5
1.5
0.75
NO
1.5
1.25
0.75
NC
15
15
6
0.05
0.03
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
Inductive load (A)
Inductive load
NO
Motor load
NC
5
3
1.5
0.05
0.03
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
NO
2.5
1.5
0.75
Inrush
current
NC
NO
30 A max.
15 A max.
XE-@
XV-@
XV2-@
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
Model
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Current
15 A
15 A
15 A
0.5 A
0.25 A
Horsepower
1/8HP
1/4HP
---
Operating speed
Durability
*2
Characteristics
Degree of protection
Mechanical
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s
2
min.
100 m/s
2
min.*4
50 m/s
2
min.*5
−10°C
to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
ZE
Electrical
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between current-
carrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-car-
rying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above figures are initial values.
*1. IP65 for
@-N
models and IP60 for
@-Q
models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
XE (L/R = 0)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
50
250 VAC
1,000
125 VAC
500
250 VAC
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
ZE (cosφ = 0.4)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
500
250 VAC
480 VAC
100
50
0
2
4
6
8
10
12
14
16
XE (L/R = 7 ms)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
100
70
50
30
20
250 VAC
125 VAC
125 VAC
0
1
2
3
5
Switching current (A)
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
COM
NC
NO
Contact Form
Pin plunger
Tightening band
Case
Rubber cap (CR)
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Two, M4
(length: 45)
(Unit: mm)
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
PT
OP
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
25.4
±
0.12
24
OP
23
23
25.4
±
0.3
25.4
±
0.3
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Two, M4
(length: 45)
19.1 dia.
×
7.9 *1
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
39.7
*2
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
23
25.4
±
0.3
* Stainless steel roller
25.4
±
0.3
86
25.4
±
0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Operating force
Release force
Pretravel
Over Travel
Movement Differential
Operating Position
Model
OF
RF min.
PT max.
OT min.
MD max.
OP
ZE-Q-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XE-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-Q22-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q22-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q21-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-QA2-2
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
---
XE-QA2-2
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia.
×
9 *1
XE-QA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Operate in this
direction only
Sealed Plunger
ZE-N-2
XE-N-2
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
39.7
*2
PT
PT
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
Two, M4
(length: 45)
Two, M4
(length: 45)
17
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
OP
23
25.4
±
0.3
25.4
±
0.12
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
24
25.4
±
0.3
25.4
±
0.12
24
Sealed Roller Plunger
ZE-N22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
Sealed Crossroller Plunger
ZE-N21-2
PT
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
OP
Two, M4
(length: 45)
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
23
23
25.4
±
0.3
25.4
±
0.3
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
19.1 dia.
×
7.9 *1
39.7
(23.1)
*2
One-way Action Sealed Roller Arm Lever
18.7 dia.
×
9 *1
ZE-NA277-2
XE-NA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
39.7
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
Two, M4
(length: 45)
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
17
23
23
25.4
±
0.3
25.4
±
0.3
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
A dynamic display screen made with g2553, made with 12864, plus a temperature sensor 18b20 and a clock chip 1302. If you are interested, please take a look and help me improve it....
Zhou Ligong USB CAN idle at home, model: Zhou Ligong USBCAN-Ⅱ+, produced by Guangzhou Zhiyuan Electronics Co., Ltd., brand new, unopened and unused, complete accessories, I will not introduce the qual...
I have chosen a type of current transformer, a through-core type, with a transformation ratio of 5A/5mA. I would like to ask if the 5A on the primary side refers to the rated value or the maximum valu...
I set the registers according to the epwm_trip_zone routine in Ti, but now the program can also do what I want. When the conditions are met, after the software triggers the interrupt, the specified ep...
As shown in the picture, what role does the capacitor in the blue box play?
For these two detection quantities that need to be subtracted, adding this capacitor can improve the ability to suppress com...
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i] In recent years, with the continuous improvement of people's living standards, the three series of small household appliances, n...
As LEDs continue to improve in almost every aspect of performance and cost, LED lighting is being used in an increasingly wide range of applications, among which LED street lights are a focus of in...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
At very low temperatures, certain metals and alloys lose their resistance to electric
current
and become
superconductors
. Two parameters that are often measured are the transition ...[Details]
D5026A is a driver IC designed by Shanghai Debei Electronics for energy-saving LED display screens. Its design concept is energy-saving and compatible with existing solutions, that is, it can be ...[Details]
introduction
At present, the research on micron and nanotechnology is very active, which has led to the rapid development of microtechnology and micro-mechanical electronic system (MEMS) t...[Details]
0 Introduction
In the design and construction of communication systems,
communication power supply
is called the heart of the communication system. The power supply system will dire...[Details]
At present, products in the field of monitoring generally focus on the field level, that is, the client/server (C/S) model is adopted, the purpose of which is to ensure the stability and reliability o...[Details]
1. Introduction
Due to the good programmability and superior performance of FPGA, the number of embedded systems using FPGA chips in LCD splicing screens is increasing rapidly, especially in t...[Details]
0 Introduction
In microwave, radar, radio and television, and communication systems, the problem of coupling RF power is often encountered. A directional coupler is a directional power divide...[Details]
O Introduction
For people who are in the wild, a question that they are more concerned about is the altitude of the place where they are. However, there are very few such products on the mar...[Details]
In the industrial production process, flow measurement is a widely used measurement physical quantity. In special cases, such as vertical oil wells, when it is not easy to install probes outside the p...[Details]
According to the National Shipbuilding Industry Economic Research Center, the total shipbuilding capacity in my country last year was about 9×106t. The new ship orders exceeded 17×106t, accounting ...[Details]
When programming in C and assembly, there are interface issues between variables and functions in C and assembly.
Variables defined in a C program are put into the .bss area after being compile...[Details]
1. Introduction
Diesel engine test is the last key process in the diesel engine production process, which plays a very important role in the manufacturing quality of diesel engines. Its main c...[Details]
With the development of my country's economy, environmental pollution caused by energy consumption is becoming more and more serious. Sulfur dioxide and nitrogen oxides emitted from coal-fired flue...[Details]