Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
•
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
•
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
•
Terminals face the front when the cover is removed for
easy connection.
•
Switches with ground terminals have CE marking.
•
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read
Safety Precautions
on page 8 to 9 and
Safety Precautions for All Limit Switches.
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(4) Conduit/Ground Terminal
*
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
AC
Plunger
DC
AC
Roller plunger
DC
General
purpose
AC
Crossroller plunger
DC
AC
Roller arm lever
DC
One-way action roller
arm lever
AC
DC
AC
Sealed plunger
DC
Sealed roller plunger
Sealed
(Booted)
Sealed crossroller
plunger
Sealed roller arm lever
DC
One-way action
sealed roller arm lever
AC
DC
AC
AC
AC
Model
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
Approved
standards
UL
●
CSA
●
Model
ZV-Q-2
XV-Q-2
Approved
standards
UL
●
CSA
●
Model
ZV2-Q-2
XV2-Q-2
Approved
standards
UL
●
CSA
●
●
●
ZV-Q22-2
XV-Q22-2
●
●
ZV2-Q22-2
XV2-Q22-2
●
●
●
●
ZV-Q21-2
XV-Q21-2
●
●
ZV2-Q21-2
---
●
●
●
●
ZV-QA2-2
XV-QA2-2
●
●
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
---
●
●
●
●
---
---
●
●
●
●
ZV-N-2
XV-N-2
●
●
ZV2-N-2
XV2-N-2
●
●
●
●
●
●
●
●
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
●
●
●
●
●
●
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
●
●
●
●
●
●
●
●
ZV-NA277-2
---
●
●
ZV2-NA277-2
XV2-NA277-2
●
●
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
UL
CSA
CCC (CQC)
Standard
UL508
CSA C22.2 No.14
GB14048.5
File No.
E76675
LR45746
2003010303077623
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Resistive load
NC
ZE-@
ZV-@
ZV2-@
15
15
10
0.5
0.25
10
10
10
10
3
3
3
3
3
1.5
NO
Lamp load
NC
3
2.5
1.5
0.5
0.25
1.5
1.5
1.5
1.5
0.75
NO
1.5
1.25
0.75
NC
15
15
6
0.05
0.03
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
Inductive load (A)
Inductive load
NO
Motor load
NC
5
3
1.5
0.05
0.03
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
NO
2.5
1.5
0.75
Inrush
current
NC
NO
30 A max.
15 A max.
XE-@
XV-@
XV2-@
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
Model
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Current
15 A
15 A
15 A
0.5 A
0.25 A
Horsepower
1/8HP
1/4HP
---
Operating speed
Durability
*2
Characteristics
Degree of protection
Mechanical
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s
2
min.
100 m/s
2
min.*4
50 m/s
2
min.*5
−10°C
to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
ZE
Electrical
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between current-
carrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-car-
rying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above figures are initial values.
*1. IP65 for
@-N
models and IP60 for
@-Q
models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
XE (L/R = 0)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
50
250 VAC
1,000
125 VAC
500
250 VAC
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
ZE (cosφ = 0.4)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
500
250 VAC
480 VAC
100
50
0
2
4
6
8
10
12
14
16
XE (L/R = 7 ms)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
100
70
50
30
20
250 VAC
125 VAC
125 VAC
0
1
2
3
5
Switching current (A)
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
COM
NC
NO
Contact Form
Pin plunger
Tightening band
Case
Rubber cap (CR)
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Two, M4
(length: 45)
(Unit: mm)
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
PT
OP
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
25.4
±
0.12
24
OP
23
23
25.4
±
0.3
25.4
±
0.3
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Two, M4
(length: 45)
19.1 dia.
×
7.9 *1
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
39.7
*2
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
23
25.4
±
0.3
* Stainless steel roller
25.4
±
0.3
86
25.4
±
0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Operating force
Release force
Pretravel
Over Travel
Movement Differential
Operating Position
Model
OF
RF min.
PT max.
OT min.
MD max.
OP
ZE-Q-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XE-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-Q22-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q22-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q21-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-QA2-2
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
---
XE-QA2-2
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia.
×
9 *1
XE-QA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Operate in this
direction only
Sealed Plunger
ZE-N-2
XE-N-2
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
39.7
*2
PT
PT
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
Two, M4
(length: 45)
Two, M4
(length: 45)
17
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
OP
23
25.4
±
0.3
25.4
±
0.12
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
24
25.4
±
0.3
25.4
±
0.12
24
Sealed Roller Plunger
ZE-N22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
Sealed Crossroller Plunger
ZE-N21-2
PT
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
OP
Two, M4
(length: 45)
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
23
23
25.4
±
0.3
25.4
±
0.3
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
19.1 dia.
×
7.9 *1
39.7
(23.1)
*2
One-way Action Sealed Roller Arm Lever
18.7 dia.
×
9 *1
ZE-NA277-2
XE-NA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
39.7
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
Two, M4
(length: 45)
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
17
23
23
25.4
±
0.3
25.4
±
0.3
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
[size=5]As shown in the picture, I saw that the time requirement in the IIC protocol is greater than 4us[/size] [size=5]Why can the program in Zhengdian Atom be 2us, even so, this program actually run...
In fact, you just need to install a VNC login client on your mobile phone. The more useful one is the VNC client software of realvnc. PC/android, etc. all use the VNC client of this company. After the...
I recently made a recording with wm9712 and made a test program. It returned an error when if (waveInOpen(&m_hWaveIn,WAVE_MAPPER,&m_WaveFormatEx,(DWORD)WaveInProc,NULL,CALLBACK_FUNCTION) != MMSYSERR_N...
[align=left]Kernel transplantation is relatively complex and cannot be completed in one step. We can only win by taking one step at a time. The purpose of this section is to modify the kernel so that ...
0 Introduction
With the development of my country's economy, the number of motor vehicles continues to increase. The growth of existing roads and other hardware facilities can no longer meet t...[Details]
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The way to reduce costs is
① Use the Bluetooth data transmission function of mobile ph...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
In the previous series, we have listed some basic knowledge of C language in Tables 1 to 3. We hope that beginners can strengthen their memory of the above tables and gradually learn to use them wh...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
PV inverter manufacturer SMA has launched its first DC arc fault circuit interrupter (AFCI) PV inverter and has received UL certification.
The new SunnyBoy AFCI inverter models include 3000-US...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
Spatial Division Multiplexing (SDM) MIMO processing can significantly improve spectrum efficiency and thus greatly increase the capacity of wireless communication systems. Spatial Division Multip...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
LED light sources have many environmental advantages, but early products still have certain technical bottlenecks in heat dissipation and high brightness design that cannot be broken through....[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
At present, how various communication technologies will evolve after 3G is a focus of great concern in the industry. Especially for TD-SCDMA, whether it can achieve smooth evolution to the next gen...[Details]