EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/FNQ-R-1

Description
fuse 1A 600v T-lag UL csa
CategoryCircuit protection   
File Size307KB,4 Pages
ManufacturerEaton
Environmental Compliance  
Download Datasheet Parametric View All

BK/FNQ-R-1 Overview

fuse 1A 600v T-lag UL csa

BK/FNQ-R-1 Parametric

Parameter NameAttribute value
Datasheets
FNQ-R
Product Photos
FNQ Series
Standard Package100
CategoryCircuit Protecti
FamilyElectrical, Specialty Fuses
Fuse TypeSlow Blow, Time Lag
Voltage - Rated600VAC
Curre1A
Package / Case5AG, 10mm x 38.1mm
Size / Dimensi0.406" Dia x 1.500" L (10.30mm x 38.10mm)
Mounting TypeHolde
Col-
Operating Temperature-
Melting I²-
DC Cold Resistance-
Other NamesBK-FNQ-R-1
L
IMITRON
™ Class CC
FNQ-R — 600Vac,
1
4
-30A, Time-Delay Fuses
Dimensions - in
1.5" (± 0.031)
(38.1mm)
0.41" (± 0.005)
(10.3mm)
Description:
Advanced protection Class CC current-limiting,
time-delay fuses.
Catalog Symbol:
FNQ-R-(amp)
Ratings:
Volts — 600Vac
— 300Vdc (15 & 20A)
Amps —
1
4
-30A
IR — 200kA Vac RMS Sym.
— 20kA Vdc (15 & 20A)
Agency Information:
CE, UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273
CSA Certified, Class CC CSA, Class 1422-01,
File 53787–HRC-MISC
RoHS Compliant*
* FNQ-R- ⁄
4
not RoHS complaint.
1
Features:
• Provides 10X better current limitation to help prevent
equipment damage caused by short-circuit events.
• 200kA interrupting rating complies with NEC
®
Section 110.9
for today's large capacity systems.
• Fast-acting fuse helps prevent equipment damage caused
by short-circuit events.
• Rejection type fuse fits both standard and rejection-style
holders.
• The Class CC FNQ-R Limitron fuse meets the needs of
control circuit transformer protection.
• FNQ-R fuses can be sized according to NEC
®
and UL
requirements and still allow the high inrush currents, with
significantly more time-delay than the UL minimum value of
12 seconds at 200% for Class CC fuses.
• Ideal for critical industrial or commercial applications that
have specific current limitation requirements.
Applications:
• Branch Circuits
• Small Control Transformers
• Line Protection
• Industrial Control
3-Pole
BC6033_
CHCC3D_
OPM-NG-_
OPM-1038_
OPM-1038_SW
Catalog Numbers (amps)
FNQ-R-
1
4
FNQ-R-
3
10
FNQ-R-
4
10
FNQ-R-
1
2
FNQ-R-
6
10
FNQ-R-
3
4
FNQ-R-
8
10
FNQ-R-1
FNQ-R-1
1
8
FNQ-R-1
1
4
Amp Rating
1
4
-30
FNQ-R-1
3
10
FNQ-R-1
4
10
FNQ-R-1
1
2
FNQ-R-1
6
10
FNQ-R-1
8
10
FNQ-R-2
FNQ-R-2
1
4
FNQ-R-2
1
2
FNQ-R-2
8
10
FNQ-R-3
Carton Qty.
10
FNQ-R-3
2
10
FNQ-R-3
1
2
FNQ-R-4
FNQ-R-4
1
2
FNQ-R-5
FNQ-R-5
6
10
FNQ-R-6
FNQ-R-6
1
4
FNQ-R-7
FNQ-R-7
1
2
FNQ-R-8
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-17
1
2
FNQ-R-20
FNQ-R-25
FNQ-R-30
Recommended Fuse Blocks and Holders
Fuse Amps
0-30
1-Pole
2-Pole
Open Blocks
BC6031_
BC6032_
DIN-Rail Holders
CHCC1D_
CHCC2D_
Panel Mount Holders
HPS
HPF
In-Line Holders
HEY
HEZ
0-30
Carton Quantity:
0-30
0-30
Maximum Acceptable Rating of Overcurrent Device
Rated Primary
Current (Amps)
< 2A
2A to 9A
> 9A
† UL 508A Table 42.1.
†† 300% for other than motor control applications.
0114
BU-SB14042
Maximum Rating of Overcurrent
Protective Device Expressed As a Percent
of Transformer Primary Current Rating
500
††
167
125
For additional information on Class CC fuse blocks and
holders, see Data Sheets:
• Open Blocks # 1105 (BC Series)
• DIN-Rail Holders # 3185 (CHCC), # 1109 (OPM),
# 1102 (OPM-1038), 1103 (OPM-1038_SW),
• Panel Mount Holders # 2113 (HPS), # 2114 (HPF)
• In-Line Holders # 2126 (HEY), # 2130 (HEZ)
Page 1 of 4
Data Sheet # 1014
EZ-USB FX series peripheral circuit design
To download the entire book, you need to download all parts (part1--part8)...
追梦1988 Industrial Control Electronics
Circuit
Is there a way to invert an analog signal?...
hql724914 PCB Design
Help: How to add units to Allegro dimensioning
:Cry: Help, help, as the title says, like this picturehow do I add units when dimensioning? ~~ I use allegro...
木犯001号 PCB Design
About ADC0 of C8051F120
There is an analog voltage input from AIN0.0. It is required to read the correct digital through the AD conversion of the analog voltage by the single-chip microcomputer. How to achieve it? It should ...
ZXZ2002 Embedded System
Using mmap to copy files
Using mmap to copy files is a kernel operation, but understanding the principle is helpful for further learning. http://blog.chinaunix.net/space.php?uid=20937170do=blogid=2983502...
gongping11 Linux and Android
robot
The control of robots is a typical application of DSP in motors. Let’s first talk about the development of wheeled robots in this area, haha!...
gaoxiao Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1581  968  1059  1918  849  32  20  22  39  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号