EEWORLDEEWORLDEEWORLD

Part Number

Search

177-710-2-69CS0J1-18FWN

Description
Cable Assembly, 30AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

177-710-2-69CS0J1-18FWN Overview

Cable Assembly, 30AWG,

177-710-2-69CS0J1-18FWN Parametric

Parameter NameAttribute value
Objectid7004906856
Reach Compliance Codeunknown
YTEOL8.75
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.051 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors69
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.385 Ω
shieldYES
stay7X38
Wire gauge30 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
[PSoC4 experience] Take the first step: make a good relay driver board
Without going into the details, let's take a look at the pictures. Pictures speak louder than words....
辛昕 MCU
Low frequency digital phase meter
[i=s] This post was last edited by paulhyde on 2014-9-15 04:24 [/i] As the title says, share with you...
0500110118 Electronics Design Contest
28035 CCS5 IQMATH call
I found the following small problem when calling IQMATH function in CCS5: Here is my code: _iq30 in2, out2; in2 =_IQ10(0.333*PI/(2*PI)); out2 =_IQ10sinPU(in2); temp = _IQ10toF(out2); in2 =_IQ30(0.333*...
欢欢 Microcontroller MCU
About CORTEX M on ucos
I tried to port ucos2 to cortex m0, referring to the code of ucos over cortex m3.There is one thing that is not clear: starting from the main function, the system uses MSP as the stack by default, whi...
sringosling stm32/stm8
If wireless transmission is used for data exchange between PLC and PLC
If data exchange between PLCs is done by wireless transmission, who has the solution and experience in this regard?...
dataidz Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1956  489  1239  2861  618  40  10  25  58  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号