Part Number

Search

177-740-5-67CS0J5-18BVN

Description
Cable Assembly, 30AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

177-740-5-67CS0J5-18BVN Overview

Cable Assembly, 30AWG,

177-740-5-67CS0J5-18BVN Parametric

Parameter NameAttribute value
Objectid7005112015
Reach Compliance Codeunknown
YTEOL9.35
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D FEMALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.051 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.467 mm
MIL complianceYES
Number of conductors67
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.385 Ω
shieldYES
stay7X38
Wire gauge30 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
ddk issues
C# uses ddk to implement the problem of receiving USB data...
charlin Embedded System
Teacher: What is the principle of connecting ALE to RES in this way?
As the title says, this is the actual wiring (surveyed) of a controller, SM5964. What is the principle of ALE being connected like this? What are the benefits? The problem is that the ALE signal will ...
cs5664798595 Embedded System
VR products implemented with FPGA
3D printed housing FPGA controlled display [img]http://image.slidesharecdn.com/fpgax7mft15slideshare-150812024401-lva1-app6892/95/fpga-de-vr-robot-avatar-maker-faire-tokyo-2015-1-638.jpg?cb=1439347668...
5525 FPGA/CPLD
The harm and solution of power quality problems
Introduction: Power supply is the heart of information systems and electronic products. The quality of AC power supply determines whether information systems and electronic products can work normally....
songbo Energy Infrastructure?
How to use PsCreateSystemThread
I would like to ask you experts, where should the system thread function PsCreateSystemThread be created? After I created the thread in deviceIoCtrl, when installing the driver, the computer would res...
lssbw Embedded System
Why can't I create a smart device application in the VS2003 I just installed?
I just installed vs2003. There is no problem in developing general windows applications. But when creating a winCE windows application, the "Form1.cs [Design]" window shows: "Error loading the documen...
kjpioo Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 946  1903  296  2278  2647  20  39  6  46  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号