EEWORLDEEWORLDEEWORLD

Part Number

Search

307E-823-2004

Description
Board Connector, 23 Contact(s), 1 Row(s), Male, Right Angle, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle
CategoryThe connector    The connector   
File Size173KB,1 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

307E-823-2004 Overview

Board Connector, 23 Contact(s), 1 Row(s), Male, Right Angle, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle

307E-823-2004 Parametric

Parameter NameAttribute value
Objectid1153077472
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresW/LOCKING RAMP,W/O HOOK
body width0.37 inch
subject depth0.45 inch
body length3.582 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN-PB ON NI
Contact completed and terminatedTIN/LEAD OVER NICKEL
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
Dielectric withstand voltage1500VAC V
maximum insertion force8.896 N
Insulation resistance500000000000 Ω
Insulator colorNATURAL
insulator materialGLASS FILLED POLYBUTYLENE TEREPHTHALATE
Manufacturer's serial number3000
Plug contact pitch0.156 inch
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
polarization keyPOLARIZED KEY
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.218 inch
Terminal pitch3.9624 mm
Termination typeSOLDER
Total number of contacts23
Evacuation force-minimum value.556 N
.156” (3.96mm)
Through Hole Right Angle Connector
3000 SERIES “TERMACON”
PART NUMBER LEGEND
30XX-XXX-XXXX
CONTACT TAIL DIMS (SEE TABLE 2)
CONTACT MATERIAL (SEE NOTE 1)
OPTIONS
2 - HIGH INSERTION FORCE CONTACT
3 - LOW INSERTION FORCE CONTACT
NO. OF POSITONS (SEE TABLE 1)
OPTIONS
0-
1-
3-
6-
7-
8-
WITH LEGS
WITH HOOKS
WITH HOOKS AND LOCKING RAMP
WITH LOCKING RAMP
WITH HOOKS, LOCKING RAMP AND POLARIZING KEY
WITHOUT HOOKS, W/ LOCKING RAMP AND POLARIZING KEY
CONTACT FINISH (SEE NOTE 2)
INSULATOR MATERIAL (SEE NOTE 1)
MATING HEADERS: 3100 SERIES
POLARIZING KEY &
LOCKING RAMP
LEG
HOOK
Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
Telephone: 847.392.3500 • Fax: 847.392.9404
email: mcpsales@methode.com • Web Page: www.methode.com
How to create a data file using SQLCE3.0?
The book says: On the PDA, use the isqlw30 tool to create a data file ****.sdf. But when I open this tool, I can't create it. After clicking the connect database, it asks me to select the data file. I...
Jweikit Embedded System
Simulation software consulting
Does anyone know how to perform hardware simulation on FPGA/CPLD? That is, use MAX+plush2 to generate .pof/.sof files, and then use software hardware simulation. Does anyone know of such software?...
eeleader FPGA/CPLD
gossip
I would like to ask how are the dormitory relations in college? I personally think that boys may be better, while girls are worse. right?...
duxiaowen Embedded System
Introduction to the e-sports competition evaluation process
[i=s]This post was last edited by paulhyde on 2014-9-15 03:29[/i] [align=center][size=4][b]Brief introduction to the electronic competition process[/b][/size][/align] [align=left][size=4] I'm new here...
干磨河 Electronics Design Contest
Mifare Standard IC Card MF1 IC S50 Functional Specification
Philips developed the wireless smart card chip Mifare? MF1 IC S50 according to ISO/IEC 14443A standard. The communication layer of this chip Mifare? RF interface complies with Part 2 and Part 3 of ISO...
rain Test/Measurement
Actions recruitment analog design engineer written test questions
Actions recruitment analog design engineer written test questions...
analogstudy Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1233  1602  2670  935  884  25  33  54  19  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号