Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed
and not Moisture Sensitive - MSL = N/A: Not Applicable
Pb
RoHS/RoHS II
11.5 x 5.0 x 2.5 mm
| | | | | | | | | | | | | | |
FEATURES:
• Reduced height at 2.5mm
• High reliability & Low Cost
• Tight stability & extended temperature
• Proven resistance welded metal package
APPLICATIONS:
• Home electronics
• Computers, modems, and communications
• High-precision TCXO and clock applications
• Microprocessors
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Minimum
3.579545
3.579545
Operation mode
24.01
24.01
Operating Temperature
Storage Temperature
Frequency Tolerance
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging @ 25°C per year
Insulation Resistance
Drive Level Dependency (DLD,
Minimum 7 points tested: from 1µW to
500µW)
0
-55
-50
-50
See table 1 below
7
18
100
500
±10
25% of Max
ESR
Max ESR in
Table 1
1000
±5
Typical
Maximum
70
24.0
70.00
50.00
+70
+125
+50
+50
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
MΩ
ppm
Ω
Ω
MHz
Fundamental AT-
cut (Standard)
3
rd
OT AT-cut
(Standard)
Fundamental AT-
cut or BT-cut (See
options)
See options
See options
See options
Units
Notes
See options
@ 100Vdc ± 15V
Δfrequency (Max –
Min)
ΔESR (Max – Min)
Max ESR over DLD
range
Table 1
Frequency (MHz)
3.579 - 4.999 (Fund.)
5.000 - 5.999 (Fund.)
6.000 - 7.999 (Fund.)
8.000 - 8.999 (Fund.)
9.000 - 9.999 (Fund.)
10.000 - 15.999 (Fund.)
16.000 - 50.000 (Fund.)
24.01 - 31.999 (3rd O/T)
32.000 - 70.00 (3rd O/T)
ABRACON IS
ISO 9001 / QS 9000
ISO 9001:2008
CERTIFIED
ESR(Ω) max.
180
120
100
80
60
50
40
100
80
Revised: 04.21.16
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/49US (AT49) MICROPROCESSOR CRYSTAL
ABL2 Series
OPTIONS AND PART IDENTIFICATION:
Pb
RoHS/RoHS II
11.5 x 5.0 x 2.5 mm
| | | | | | | | | | | | | | |
ABL2 -
Frequency in MHz
Please specify the
frequency in
xx.xxxxMHz.
e.g. 14.3181MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF
or S for series
Custom ESR if other
than standard
R□
□: Specify
a value in
Ω
(e.g.: R40)
MHz-
-
-
-
-
-
Packaging
Blank: Bulk
T: Tape & Reel
TRAY: Tray
Value Added
I
Insulator Tab
L2
Middle 3rd lead
QXX
Trimmed leads
Q15
for 0.15" length
Oscillation Mode
F: Fund. AT>24MHz
FB***: Fund. BT>24MHz
Freq. Tolerance
Blank: ± 50 ppm
H5: ± 5 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
Blank: ± 50 ppm
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
R: ± 150 ppm
Operating Temp.
Blank: 0°C ~ +70°C
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J*: -40°C ~ +105°C
K*: -40°C ~ +125°C
L*: -55°C ~ +125°C
NOTE:
* Frequency stability ±50ppm, ±100ppm, ±150ppm only. Contact ABRACON for tighter frequency stability.
** -10°C to +60°C only.
*** Fundamental BT frequency stability ± 100ppm max at -10°C ~ +60°C only.
ABRACON IS
ISO 9001 / QS 9000
ISO 9001:2008
CERTIFIED
Revised: 04.21.16
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/49US (AT49) MICROPROCESSOR CRYSTAL
ABL2 Series
OUTLINE DIMENSIONS:
Pb
RoHS/RoHS II
11.5 x 5.0 x 2.5 mm
| | | | | | | | | | | | | | |
ABL2 SERIES HC49/US (AT49)
MICROPROCESSOR CRYSTAL
Date of Issue: Jan. 2
nd
, 2013
Page (8) of (10)
8.0
Packaging:
11.5 x 5.0 x 2.5 mm
Abracon Drawing # 450715
Revision #: K
L
Packaging
5.5mm Min
Bulk
Tape & Reel without Insulator Tab
20.0 ± 0.5mm
T= Tape and reel (1,000pcs/reel)
Insulator Tab
15.5mm Min
Tape & Reel with
Dimensions: inch (mm)
TAPE & REEL:
T= Tape and reel (1,000pcs/reel)
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO 9001 / QS 9000
ISO 9001:2008
CERTIFIED
Visit www.abracon.com for Terms & Conditions of Sale
Revised: 04.21.16
30332 Esperanza, Rancho Santa Margarita, California 92688
Recently, when I installed Renesas development software, it prompted me to install .NET FRAMWORK 4 before installing the development software. My computer is Win7 Ultimate, and the installation failed...
Drawing with GDI is very flashy. I want to use double buffering to achieve it, but I found that the classes used in the double buffering examples I searched on the Internet are not available under Win...
Why can't I use the MSP-EXP430G2 simulation instance LaunchPad_Temp? ?
The program has been downloaded to msp430g2231, but the LaunchPad_Temp_GUI in salc436a downloaded from TI official website cannot...
Microchip's PIC18F46J50 is a low-power, high-performance 8-bit USB microcontroller (MCU) using nanoWatt XLP technology. The current in deep sleep mode can be as low as 13nA, the operating voltage i...[Details]
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
Two simple circuits are implemented to drive two LEDs from a battery powered microprocessor.
This design is based on a circuit that uses three resistors and a microprocessor I/O pin as an input h...[Details]
Microcalorimetry
is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small sample sizes or slow heating rat...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
Traditional
virtual instruments
consist of a data acquisition
board
based on PCI bus and
corresponding software. However, with
the rapid development of
computer
network techno...[Details]
The ARINC429 bus is one of the most commonly used communication buses between various subsystems of avionics. As the "skeleton" of modern avionics systems, once the bus system or the attached airbo...[Details]
Abstract: In order to realize wireless automatic alarm and monitoring of major safety places, based on the basic principle of pyroelectric infrared sensing, a detector for receiving infrared radia...[Details]
Current
measurement:
Magnetic balance Hall current
sensor
is used
. The sensor can measure AC from DC to 100kHz.
In automatic measurement and control systems, it is often nec...[Details]