EEWORLDEEWORLDEEWORLD

Part Number

Search

Y2011U2B801NB

Description
KEYLOCK SWITCH, DPDT, LATCHED, 0.02A, 20VDC, PANEL MOUNT-THREADED, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,8 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

Y2011U2B801NB Overview

KEYLOCK SWITCH, DPDT, LATCHED, 0.02A, 20VDC, PANEL MOUNT-THREADED, ROHS COMPLIANT

Y2011U2B801NB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1081604943
package instructionROHS COMPLIANT
Reach Compliance Codenot_compliant
ECCN codeEAR99
body height23.14 mm
Body length or diameter17.78 mm
Contact (AC) maximum rated R load.02A@20VAC
Maximum contact current (AC)0.02 A
Maximum contact current (DC)0.02 A
Contact (DC) maximum rated R load.02A@20VDC
Maximum contact voltage (AC)20 V
Maximum contact voltage (DC)20 V
Electrical life10000 Cycle(s)
Graduation angle90 deg
JESD-609 codee4
Manufacturer's serial numberY
Installation featuresPANEL MOUNT-THREADED
Number of independent keys2
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeKEYLOCK SWITCH
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Termination typeSOLDER
Y Series
4, 5 & 6 Tumbler Switchlocks
Features/Benefits
Anti-static switch—exceeds
20 KV DCstatic resistance
Momentary models available
Wire leads and harnesses available
Typical Applications
Point-of-sale terminals
Cash registers
Computers
Patent No. 4,639,562
Models Available
Specifications
CONTACT RATING: Q contact material: 4 AMPS @ 125 V AC or
28 V DC; 2 AMPS @ 250 V AC (UL/CSA). See page M-9 for
additional ratings.
ELECTRICAL LIFE: 10,000 make-and-break cycles at full load.
CONTACT RESISTANCE: Below 10 m
typ. initial @ 2-4 V DC,
100 mA, for both silver and gold plated contacts.
INSULATION RESISTANCE: 109
min.
DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level.
INDEXING: 45º or 90º, 2-4 positions (4&5 tumbler switchlocks).
45º, 3 positions; or 90º, 2 positions (6 tumbler tubular
switchlocks).
Other functions available, consult Customer Service Center.
STATIC RESISTANCE: Anti-static models exceed 20 KV DC static
resistance @ sea level, lock body to terminals.
MOUNTING TORQUE: 10 in./lbs.; 14 in./lbs max.
Materials
LOCK: Zinc alloy with stainless steel facing, std. (4 & 5 tumbler lock
and 6 tumbler tubular lock).
KEYS: Two nickel plated brass keys, with code number, std.
(4 and 5 tumbler lock). Two die cast chrome plated zinc alloy
keys,std. (6 tumbler lock).
SWITCH HOUSING: Glass filled polyester (UL 94V-0).
CONTACTS AND TERMINALS: Q contact material: Copper, silver
plated. See page L-9 for additional contact materials.
MOUNTING NUT: Zinc alloy.
MOUNTING CLIP: Steel, zinc plated.
DRESS NUT: Brass, nickel plated.
TERMINAL SEAL: Epoxy.
NOTE:
Any models supplied with Q, B or G contact material are RoHS compliant.
NOTE:
Specifications and materials listed above are for switchlocks with standard options.
For information on specific and custom switchlocks, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages L–4 through L–10. For additional options not shown in catalog, consult Customer Service Center.
Switch and Lock Function
Y10013
SP, 45°, keypull pos. 1
Keying
2
Two nickel plated brass keys (4 &
Y1011U
SP, 90°, keypull pos. 1 & 2
5 tumbler) or two die cast zinc alloy keys with
Y1001U
SP, 45°, keypull pos. 1 & 3
chrome plating (6 tumbler)
Y2001U
DP, 45°, keypull pos. 1 & 3
Y10082
SP, 45°, keypull pos. 1
6
Two nickel plated brass keys with code on lock face
Y20082
DP, 45°, keypull pos. 1
Lock Type
Y100AA
SP, 45°, keypull pos. 1, 2 & 3
A
4 Tumbler lock (YXO8 models)
Y200AA
DP, 45°, keypull pos. 1, 2 & 3
C
4 Tumbler lock with detent
Y100AB
SP, 45°, keypull pos. 1, 2, 3 & 4
V
6 Tumbler tubular lock
Y200AB
DP, 45°, keypull pos. 1, 2, 3 & 4
B
5 Tumbler lock
Y10113
SP, 90°, keypull pos. 1
R
4 Tumbler lock with detent and anti-Static switch
Y20113
DP, 90°, keypull pos. 1
W
6 Tumbler tubular lock with anti-Static switch
Y1011C
SP, 90°, keypull pos.2
Y2011C
DP, 90°, keypull pos. 2
Lock Finish
Y2011U
DP, 90°, keypull pos. 1 & 2
2
Stainless steel facing
Y14173
SP, 90°, keypull pos. 1
8
Gloss black facing
Terminations
Y1417U
SP, 90°, keypull pos. 1,2 & 3
F
Polished nickel facing
03
Solder lug with hole
Y10812
SP, 45°, mom., keypull pos. 1
01
Solder lug with notch
Y20812
DP, 45°, mom., keypull pos. 1
02
PC Thru-hole
Y19073
SP w/common, 90°, keypull pos. 1
07
Solder lug with hole
Y1907U
SP w/common, 90°, keypull pos. 1, 2 & 3
(Y19OXX models only)
Y1900S
SP w/common, 90°, keypull pos. 1, 2, 3 & 4
WC
Wire lead
L
Switchlock
Contact Material
Q
Silver
B
Gold
G
Gold over silver
Seal
NONE
No seal
E
Epoxy seal
Mounting/Lock Style
N
With nut
D
With clip
L
With removable dress nut and latch pawl
R
With removable dress nut
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
L–3
www.ck-components.com
The problem of lighting up basic LED lights and digital tubes at the same time
As the title says, I encountered a problem that may be quite basic when practicing: without using a timer, I only wrote a delay function to realize the flashing of LED lights and the lighting of digit...
qrswll 51mcu
Foreign representative office recruits electronic engineers
Our company is the Shenzhen representative office of a British electronics company. We are now looking for a part-time electronics engineer. 1. Graduated from a key university with a master's or docto...
nickytseng Recruitment
Easy Power Learning-Experience
This easy power supply quiz is very simple. Full marks: lol. If there is such a visual software to design power supply, it will be very convenient and the cycle will be shortened....
kready Analogue and Mixed Signal
Signal input and output issues in PCB design of RF broadband amplifier
I am making a RF broadband amplifier. The solution I found online is a three-stage amplifier. The attached PCB diagram is from someone else on the Internet. What I am confused about is why the signal ...
扶摇- PCB Design
How to turn off the watchdog between main() executions in IAR
How to disable the watchdog timer between main() calls in IAR? Someone asked this on the forum, but it was not very specific. I don't know how to do it. If you know how , please tell me. Thanks!...
243495567 Microcontroller MCU
Has anyone used 2812 or 28385 to implement a neural network?
RT, thank you for telling me....
900305 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1408  735  2908  1183  550  29  15  59  24  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号