EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/FNQ-R-1-1/4

Description
fuse 1.25a 600v T-lag UL csa
CategoryCircuit protection   
File Size307KB,4 Pages
ManufacturerEaton
Environmental Compliance  
Download Datasheet Parametric View All

BK/FNQ-R-1-1/4 Overview

fuse 1.25a 600v T-lag UL csa

BK/FNQ-R-1-1/4 Parametric

Parameter NameAttribute value
Datasheets
FNQ-R
Product Photos
FNQ Series
Standard Package100
CategoryCircuit Protecti
FamilyElectrical, Specialty Fuses
Fuse TypeSlow Blow, Time Lag
Voltage - Rated600VAC
Curre1.25A
Package / Case5AG, 10mm x 38.1mm
Size / Dimensi0.406" Dia x 1.500" L (10.30mm x 38.10mm)
Mounting TypeHolde
Col-
Operating Temperature-
Melting I²-
DC Cold Resistance-
Dynamic CatalogCC-TRON® FNQ-R Series
Other Names283-3795BK-FNQ-R-1-1-4BK/FNQ-R-1-1/4-NDBK/FNQR11/4
L
IMITRON
™ Class CC
FNQ-R — 600Vac,
1
4
-30A, Time-Delay Fuses
Dimensions - in
1.5" (± 0.031)
(38.1mm)
0.41" (± 0.005)
(10.3mm)
Description:
Advanced protection Class CC current-limiting,
time-delay fuses.
Catalog Symbol:
FNQ-R-(amp)
Ratings:
Volts — 600Vac
— 300Vdc (15 & 20A)
Amps —
1
4
-30A
IR — 200kA Vac RMS Sym.
— 20kA Vdc (15 & 20A)
Agency Information:
CE, UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273
CSA Certified, Class CC CSA, Class 1422-01,
File 53787–HRC-MISC
RoHS Compliant*
* FNQ-R- ⁄
4
not RoHS complaint.
1
Features:
• Provides 10X better current limitation to help prevent
equipment damage caused by short-circuit events.
• 200kA interrupting rating complies with NEC
®
Section 110.9
for today's large capacity systems.
• Fast-acting fuse helps prevent equipment damage caused
by short-circuit events.
• Rejection type fuse fits both standard and rejection-style
holders.
• The Class CC FNQ-R Limitron fuse meets the needs of
control circuit transformer protection.
• FNQ-R fuses can be sized according to NEC
®
and UL
requirements and still allow the high inrush currents, with
significantly more time-delay than the UL minimum value of
12 seconds at 200% for Class CC fuses.
• Ideal for critical industrial or commercial applications that
have specific current limitation requirements.
Applications:
• Branch Circuits
• Small Control Transformers
• Line Protection
• Industrial Control
3-Pole
BC6033_
CHCC3D_
OPM-NG-_
OPM-1038_
OPM-1038_SW
Catalog Numbers (amps)
FNQ-R-
1
4
FNQ-R-
3
10
FNQ-R-
4
10
FNQ-R-
1
2
FNQ-R-
6
10
FNQ-R-
3
4
FNQ-R-
8
10
FNQ-R-1
FNQ-R-1
1
8
FNQ-R-1
1
4
Amp Rating
1
4
-30
FNQ-R-1
3
10
FNQ-R-1
4
10
FNQ-R-1
1
2
FNQ-R-1
6
10
FNQ-R-1
8
10
FNQ-R-2
FNQ-R-2
1
4
FNQ-R-2
1
2
FNQ-R-2
8
10
FNQ-R-3
Carton Qty.
10
FNQ-R-3
2
10
FNQ-R-3
1
2
FNQ-R-4
FNQ-R-4
1
2
FNQ-R-5
FNQ-R-5
6
10
FNQ-R-6
FNQ-R-6
1
4
FNQ-R-7
FNQ-R-7
1
2
FNQ-R-8
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-17
1
2
FNQ-R-20
FNQ-R-25
FNQ-R-30
Recommended Fuse Blocks and Holders
Fuse Amps
0-30
1-Pole
2-Pole
Open Blocks
BC6031_
BC6032_
DIN-Rail Holders
CHCC1D_
CHCC2D_
Panel Mount Holders
HPS
HPF
In-Line Holders
HEY
HEZ
0-30
Carton Quantity:
0-30
0-30
Maximum Acceptable Rating of Overcurrent Device
Rated Primary
Current (Amps)
< 2A
2A to 9A
> 9A
† UL 508A Table 42.1.
†† 300% for other than motor control applications.
0114
BU-SB14042
Maximum Rating of Overcurrent
Protective Device Expressed As a Percent
of Transformer Primary Current Rating
500
††
167
125
For additional information on Class CC fuse blocks and
holders, see Data Sheets:
• Open Blocks # 1105 (BC Series)
• DIN-Rail Holders # 3185 (CHCC), # 1109 (OPM),
# 1102 (OPM-1038), 1103 (OPM-1038_SW),
• Panel Mount Holders # 2113 (HPS), # 2114 (HPF)
• In-Line Holders # 2126 (HEY), # 2130 (HEZ)
Page 1 of 4
Data Sheet # 1014
Dear heroes, please tell me how to learn analog circuits
I just graduated and I don't know anything. Now I am working on analog circuits. I don't know how to choose a diode. There are so many types of diodes. I don't know which one to choose. For example, t...
lg753159 Analog electronics
06 Intel Cup Winners' American Trip
[i=s] This post was last edited by paulhyde on 2014-9-15 09:00 [/i] [b] God’s joke - my unexpected trip to the United States [/b] Source: Liu Jinzhu, School of Information Science and Technology, Sout...
小丸子 Electronics Design Contest
About Tab Control (win32), urgent~~~~~~~~~~
How to add controls to each page of the TAB CONTROL control in the WIN32 development environment, such as adding a LABEL to PAGE and an EDIT BOX to PAGE2, thank you!...
xianquan Embedded System
Please recommend a heat sink (aluminum) processing manufacturer
[size=4]In the recent project, the density of circuit board components is relatively high, and the heat generated is relatively large, so it is impossible to cool the device with air in a confined spa...
tianshuihu Talking
【Repost】MIPI LCD Debugging Experience
[p=26, null, left][color=#000][font=Arial]The following is a summary of some experiences in debugging [b]MIPI DSI / CSI [/b] in recent months. Because the protocol has special documents, some common k...
Wince.Android Embedded System
[Zero-knowledge ESP8266 tutorial] Quick Start 17 Station mode creates a wifi hotspot
In the last sharing, we have used the software library to scan nearby WiFi. Next, we need to use the ZeroKnow ESP8266WiFi module to create a WiFi hotspot. I.Overview①Stationmode, also called site mode...
roc2 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 333  1870  1271  2236  1263  7  38  26  46  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号