PRODUCT INFORMATION
ÖLFLEX® HEAT 125 SC
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements
ÖLFLEX® HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3, suitable for
+125°C
Info
CPR: Article number choice under www.lappkabel.com/cpr
VDE-tested and -marked
Improved characteristics in the event of a fire
UV-resistant
Temperature-resistant
Assembly time
Halogen-free
Flame-retardant
Cold-resistant
Benefits
For safety in areas with high density of people
Reduction of flame propagation, density and toxicity of smoke gases in event of fire
Last Update (24.05.2019)
©2019 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® HEAT 125 SC
Minimises damage to buildings and equipment caused by the formation of toxic acid fumes in fires
Certified for maritime applications
Application range
For the wiring and connection of lighting, heating appliances, control cabinets, and distributors in mechanical and plant
engineering
For installation in tubes, on, in and under plaster as well as in closed installation ducts
Coil winding, electromagnets, pumps, electrical systems
Heat treatment plants, pressure die casting, heating and cooling technology
Suitable for assembling cable harnesses and wiring during switch cabinet installation
Product features
Fire behaviour:
- Flame-retardant (IEC 60332-1-2)
- Halogen-free (IEC 60754-1)
- No corrosive gases (IEC 60754-2)
- Low smoke density (IEC 61034-2)
- Low toxicity (EN 50305)
Extended fire behaviour:
H05Z-K (0,5mm² up to 1,0mm²):
see data sheet
H07Z-K (≥ 1,5mm²):
no fire propagation according to IEC 60332-3-24 respectively IEC 60332-3-25
Oil-resistant according to DIN EN 50290-2-22 (TM54)
Abrasion and notch-resistant
UV-resistant according to ISO 4892-2
Norm references / Approvals
Type H05Z-K and H07Z-K according to EN 50525-3-41 with advanced features
Germanischer Lloyd (GL)
certificate no. 11118-14HH
Product Make-up
Fine-wire, tinned-copper conductor
Electron beam cross-linked polyolefin copolymer insulation
Technical Data
Classification ETIM 5:
Classification ETIM 6:
Conductor stranding:
Minimum bending radius:
Nominal voltage:
ETIM 5.0 Class-ID: EC000993
ETIM 5.0 Class-Description: Single core cable
ETIM 6.0 Class-ID: EC000993
ETIM 6.0 Class-Description: Single core cable
Fine wire acc. to VDE 0295, class 5 / IEC 60228 class 5 from
0.5 mm²
Fixed installation: 4 x outer diameter
Up to 1.0mm² U0/U 300/500 V
From 1.5mm² U0/U 450/750 V
0.6/1kV from 1.5 mm² in the case of fixed and protected
installation
4000 V
Fixed installation: -55°C to +125°C
Test voltage:
Temperature range:
Last Update (24.05.2019)
©2019 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® HEAT 125 SC
Temporary (3.000h): up to +145°C
Note
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
Photographs and graphics are not to scale and do not represent detailed images of the respective products.
Prices are net prices without VAT and surcharges. Sale to business customers only.
Last Update (24.05.2019)
©2019 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16