VI-RC1210-MYWU-CC

Description
DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20
CategoryPower/power management    The power supply circuit   
File Size147KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-RC1210-MYWU-CC Overview

DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20

VI-RC1210-MYWU-CC Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid145006576869
package instruction,
Reach Compliance Codenot_compliant
Country Of OriginUSA
ECCN codeEAR99
Date Of Intro2017-11-21
YTEOL7.7
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, TUV, UL, VDE, CSA, IEC
high25.15 mm
Maximum input voltage32 V
Minimum input voltage21 V
Nominal input voltage24 V
JESD-30 codeR-XXMA-X20
length219.2 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Number of functions1
Output times3
Number of terminals20
Maximum output voltage16.5 V
Minimum output voltage13.5 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
ProtectOUTPUT OVER VOLTAGE
surface mountNO
technologyHYBRID
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum total power output350 W
Fine-tuning/adjustable outputYES
width187.45 mm
ComPAC
Product Highlights
DC-DC Switchers
50 to 600W
1-3 Outputs
ComPAC meets Bellcore, British
Telecom and IEC specifications for
transient protection; Bellcore, British
Telecom and FCC/VDE specifications
for EMI/RFI; and benefits from the
proven field performance, high
efficiency and inherent high reliability
of our VI-200 component-level power
converters. With input voltage ranges
optimized for industrial and
telecommunication applications,
ComPAC provides extended input
overvoltage capability, input reverse
polarity protection, undervoltage
lockout, and master disable. In a
package just .99" (25,2mm) in height,
ComPAC delivers up to 600W
from one, two or three outputs of
1 to 95Vdc.
Use the configuration chart at the right to define your
Vicor part number(s).
Features
Inputs 24, 48, and 300Vdc
Any Output: 1 to 95Vdc
High Surge Withstand:
Bellcore, British Telecom BTR 2511,
EN-61000-4-5
EMI/RFI Specifications:
Bellcore TR-TSY-000513,
British Telecom BTR 2511,
FCC Class A, EN55022 Class B
UL, CSA, TÜV (IEC 950)
80-90% Efficiency
Up to 10W/Cubic Inch
Reverse Polarity Protected
Master Disable
Overvoltage Shutdown
ComPAC Configuration Chart
Total Power
Single Outputs:
50-200W
100-400W
300-600W
Dual Outputs:
100-400W
150-600W
Triple Outputs:
150-600W
VI-LC
VI-MC
VI-NC
VI-PC
VI-QC
VI-RC
Part No.
Dimensions
8.6"L x 2.5"W x 0.99"H
(218,4 x 63,5 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
Conduction Cooled Models Available
Add "-CC" to the end of the part number
Input Voltage
Nominal
Range
1 =
W=
3 =
N =
6 =
24V
24V
48V
48V
300V
21 - 32V (1)
18 - 36V (1)
42 - 60V (2)
36 - 76V (2)
200 - 400V (2)
Output Voltage
Z
Y
0
M
1
=
=
=
=
=
2V
3.3V
5V
10V
12V
2
3
L
4
=
=
=
=
15V
24V
28V
48V
E
C
I
M
=
=
=
=
Product Grade
-10°C to +85°C
-25°C to +85°C
-40°C to +85°C
-55°C to +85°C
(1 to 95V, consult factory)
Output Power/Current
V
out
5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
V
out
< 5V
10A
15A
20A
30A
40A
Output Power/Current
V
out
5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
V
out
< 5V
20A
30A
40A
60A
80A
Output Power/Current
V
out
5V
S = 300W
P = 450W
M = 600W
V
out
< 5V
60A
90A
120A
Max output for
(1)
(2)
5V Outputs
150W
200W
>5V Outputs <5V Outputs
150W
30A
200W
40A
For latest Vicor Product Information: www.vicr.com
Vers 1
11/99 1 of 4
Communication between MCU and host computer (via wireless network card)
The single-chip microcomputer communicates with the host computer. The method of communicating with the host computer through GPRS has been developed. Now I want to realize communication with the host...
shuohua Embedded System
OTL complementary power amplifier circuit
Why is it that when the input signal is in the positive half cycle, T3 is turned on and T2 is turned off. When the input signal is in the negative half cycle, T2 is turned on and T3 is turned off....
一条乐 Analog electronics
What does this prompt mean when the power is on?
What does this prompt mean when the power is on?...
magic123456 Power technology
ESP32 branch merged into the main MicroPython repository
[size=14px]A few days ago, MicroPython officially merged the ESP32 branch into the main repository of MicroPython, while ESP32 was previously placed in a separate repository. [/size] [size=14px]After ...
dcexpert MicroPython Open Source section
"Show goods" to come to a wave of commonly used development boards
Some of these boards were made by myself, some were bought by myself, and most were obtained for free or at a discount through forum activities. This is only a part of it. There is another box that ha...
littleshrimp Special Edition for Assessment Centres
What to do if the msp430f5529 launchpad is recognized as a human body input device
Baidu has never seen such a situation......
crosssfa Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 205  2513  1112  1643  2821  5  51  23  34  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号