EEWORLDEEWORLDEEWORLD

Part Number

Search

2644LPA12100L220V3

Description
Rocker Switch, On-on-on, 5A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2644LPA12100L220V3 Overview

Rocker Switch, On-on-on, 5A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2644LPA12100L220V3 Parametric

Parameter NameAttribute value
Objectid312998023
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL7.3
Actuator colorBLUE
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features220VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@24VDC
Contact functionON-ON-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
QUARTUS 8.0 LPM module function introduction Chinese version
[i=s]This post was last edited by paulhyde on 2014-9-15 09:28[/i] :victory: For help with using IP :victory:...
凳子 Electronics Design Contest
4418 development board Win8.1 PL2303USB to serial port driver installation
Install the PL2303 driver (based on the Xunwei-4418 development board). You can find the "Xunwei_PL2303_win8.1.zip " compressedpackage in the directory "iTOP4418 development board data summary (exclud...
塔7呃 Embedded System
Very good courseware
The information is good, please support...
qiqibaby DSP and ARM Processors
LM3S1601
Please tell me whether LM3S1601 needs to be programmed through a programmer, and which programmer can read and write...
南飘燕 Microcontroller MCU
Friends who want information about PCB antennas, please take a look~~
[size=4]:congratulate:Friends who want information about PCB antennas, please have a look~~I have compiled it according to your needs~~I also hope that friends who have relevant information can also p...
okhxyyo PCB Design
Is your amplifier offset a problem?
[i=s]This post was last edited by dontium on 2015-1-23 13:31[/i] Is Your Amplifier Offset a Problem? Source: Texas Instruments Author: Bonnie Baker, Senior Applications Engineer, Texas Instruments Hav...
安_然 Analogue and Mixed Signal

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2550  1243  930  1727  2414  52  26  19  35  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号