EEWORLDEEWORLDEEWORLD

Part Number

Search

2646LHC120301LI

Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2646LHC120301LI Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2646LHC120301LI Parametric

Parameter NameAttribute value
Objectid313017367
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL9.1
Actuator colorBEIGE
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
The transition process from single chip microcomputer to embedded system
[font=宋体][size=5][color=#2f4f4f][b]Dear seniors, let's discuss how everyone moved from MCU to embedded system? Let's use it as a signpost for newbies and for seniors, let's use it as a memory of their...
2399264 ARM Technology
About the difference between CC1312R LAUNCHPAD versions
I bought a LAUNCHXL-CC1312R1 Rev: A development board online. The main chip is: XCC1312R1F3, and the development environment is: CCS920+simplelink_cc13x2_26x2_sdk_3_30_00_03. The current problem is: 1...
火辣西米秀 Wireless Connectivity
Programming Examples for the TMS320F281x eCAN
Programming Examples for the TMS320F281x eCAN...
安_然 Microcontroller MCU
Switching power supply book recommendation
[align=center] I am a novice who has a basic knowledge of analog and digital electronics. Please recommend a good introductory book on switching power supply. Please share your learning method of swit...
1348853047 Power technology
How to read register value in keil
Keil enters debugging state. I input tmod, scon, etc. in the command window below, and I can read the values of these registers, but I don't know how to read other registers. For example, the data she...
liyananliy Embedded System
[Design of an intelligent power monitor based on KW41Z] Part 4: Hardware Design
[i=s]This post was last edited by a media student on 2017-7-10 13:32[/i] [align=right][align=left][b]1.[/b][b]Background[/b][/align] [align=left]The purpose of this project is to monitor the power net...
传媒学子 NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 68  611  2629  1009  907  2  13  53  21  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号