Municipal, Industrial and Environmental Applications
LT 5 & 7 Pressure Transducers are non-submersible hydrostatic pressure
transducers specifically designed for demanding industrial applications
where the primary criteria are reliability and economy.
Applications
Non-Submersible Tank Level
Liquid Line Pressure
Pump Control
Construction Bypass Pumping
Dewatering
Features
Standard
0.25% FSO Accuracy
316 Stainless Steel Body
One Year Warranty
Pre-calibrated Pressure Ranges
Optional
0.10% FSO Accuracy
Titanium Body
Two Year Warranty
Custom Pressure Ranges
Intrinsically Safe
Lightning Protection
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 1
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Specifications
STATIC PERFORMANCE
Static Accuracy
(combined effects of non-linearity,
hysteresis and repeatability, best fit
straight line method)
Standard - 0.25% FSO
Optional - 0.10% FSO
+0.0001% FS
316 SS or Titanium; FKM;
Polyurethane or ETFE
0 to 50ºC
±0.1% FSO/ºC
-20 to 60 ºC
IP 68, NEMA 6P
BFSL method
For absolute/sealed reference min. range 0-15 PSI
Resolution
ENVIRONMENTAL
Wetted Materials
Compensated Temp Range
Thermal Error
(maximum allowable deviation from the
Best Fit Straight Line due to a change in
temperature)
Operating Temp Range
Protection Rating
When attached to polyurethane cable
Only for Electrical Connection options “A” & “D”
with Cable Type option “A”; or Electrical
Connection options “B” & “F” with Cable Type option “B”
0-5V, 0-2.5V, 0-4V
4-20
0-10V
1.5-7.5V
For mA output, for VDC output
For ranges < 5 ft. (1.5m) H
2
O,
only 4-20mA output is available
ELECTRICAL
Excitation
9-28V
–
VDC output
9-28V
–
mA output
15-28V
–
VDC output
10-28V
–
VDC output
20 mA max, 3.5 mA max
Standard - 4-20mA
Optional - 0-4 VDC, 0-5 VDC,
0-2.5 VDC, 0-10 VDC, 1.5-7.5 VDC
±0.25 mA for mA output
< 0.25 VDC for VDC output
See loop diagram for mA output
20 ohm for VDC output
100 mega ohm at 50 VDC
Polarity, surge/shorted output
Standard
–
WEEE/RoHS, CE
compliant
Optional
–
UL, CUL, and FM
PHYSICAL
Approximate Weight
Cable Jacket Material
Cable Pull Strength
Cable Number of Conductors
Cable Conductor Size
Cable Seal
0.44 lbs. (198 g) transducer
0.05 lbs./ft. (79 g/m) cable
PVC Jacket, Standard - Polyurethane
Optional - ETFE
200 lbs. (90 kg)
4
22 AWG
Molded Polyurethane
FKM Gland
For polyurethane cable
For ETFE cable
EN 61326-1:2013 and 61326-2-3:2013
Waste from Electrical and Electronic Equipment
(WEEE) and Restrictions on the use of Hazardous
Substances (RoHS)
Class I, II, III, Div. 1, Groups A,B,C,D,E,F,&G
Input Current
Output
Zero Offset
Output Impedance
Insulation Resistance
Circuit Protection
CERTIFICATIONS
LIGHTNING PROTECTION
(power supply needs to be limited to 150mA to avoid lock up of the gas tube after a suppression event)
>1,000 Operations
Life Expectancy
Peak Clamping Voltage
Response Time
Shunts
36 Volts
<10 nsecs
20,000 Amperes
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 2
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Dimensions
Electrical Termination / Loop Resistance
ELECTRICAL TERMINATION
22AWG CONDUCTORS IN A SHIELDED CABLE WITH VENT TUBE
4-20 mA
0-5 VDC
ALL
RED
BLACK
RED
BLACK
WHITE
DRAIN WIRE
+ EXCITATION
- EXCITATION
+ EXCITATION
- EXCITATION
+ SIGNAL
SHIELD
Standard Pressure Ranges for 0.25% Accuracy
Pressure Range
3
5
5
3
5
3
5
7
9
LT 5, 7 Vented
X
X
X
X
X
X
X
X
N/A
N/A
N/A
axi u
of 3
LT 5, 7 Sealed
N/A
N/A
X
X
X
X
X
X
X
X
X
PSI. Mi i u
LT 5,7 Absolute
N/A
N/A
N/A
X
X
X
X
X
X
X
X
NOTE: O er old optio is li ited to a
sealed/a solute refere e is - 5 PSI
ra ge for +/- .
% ith
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 3
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Ordering Information
TRANSDUCER
L
T Submersible Level Transducer
↓
↓
PRESSURE PORT
5
¼” –
18 Male NPT Fitting
7
½” –
14 Male NPT Fitting
↓
OUTPUT
8
4
–
20 mA
1
0
–
2.5 VDC
2
0
–
4 VDC
3
0
–
5 VDC
4
0
–
10 VDC
5
1.5
–
7.5 VDC
G
4-20 mA w/Lightning
A
0-2.5 VDC w/Lightning
B
0-4 VDC w/Lightning
C
0-5 VDC w/Lightning
D
0-10 VDC w/Lightning
E
1.5-7.5 VDC w/Lightning
↓
CABLE TYPE
A
Polyurethane
B
ETFE
C
PVC jacket
↓
ACCURACY
B
±0.25% FSO
R
±0.25% FSO with Cal Report
A
±0.10% FSO
S
±0.10% FSO with Cal Report
↓
INTRINSIC SAFETY APPROVALS
B
UL, FM & CUL (Cable Type A, B, or C Only)
D
None
↓
WARRANTY
1
A
Standard one year Warranty
B
Custom label one year Warranty
J
Extended two year Warranty
K
Custom Label extended two year Warranty
↓
MATERIAL
S
Stainless Steel
T
Titanium
↓
ELECTRICAL CONNECTION
A
Overmold (Cable Type A Only)
B
Gland Seal
(Cable Type “A” or “B” Only)
D
Overmold w/ ½” –
14 NPT Conduit (Cable Type A Only)
F
Gland Seal w/ ½” –
14 NPT Conduit
(Cable Type “A” or “B” Only)
1
Strain-relieved cable with flying leads - standard (Cable Type C Only)
2
PVC conduit strain relief
(Cable Type C Only)
↓
PRESSURE RANGE
x
x
x
Refer to chart page 4
↓
↓
↓
LABEL UNITS
P
PSI M mH2O F Ft. H2O
↓
PRESSURE REFERENCE
A
Absolute
G
Vented Gage
S
Sealed Gage
↓
CABLE LENGTH (FT)
x
x
x
Cable length in feet
↓
↓
↓
L
T
1
Contact Measurement Specialties if private labeling is required.
NORTH AMERICA
Measurement Specialties, Inc.
a TE Connectivity Company
Tel 800-522-6752
customercare.hmpt@te.com
EUROPE
Measurement Specialties (Europe), Ltd.,
A TE Connectivity Company
Tel 800-440-5100
customercare.dtmd@te.com
ASIA
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Tel 0400-820-6049
customercare.shzn@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties (MEAS), American Sensor Technologies (AST), TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products
and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no
warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and
Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product.
Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
Active Power Filter, a new technology that uses power electronics technology to suppress harmonics and improve power quality, has become a new hot spot in the field of power system research in recent ...
I am using DK-LM3S9B96... It has a solidified Bootloader. I have studied how to start the Bootloader and want to force it to start from the solidified Bootloader when powered on, without checking whet...
hFlash = OpenStore(L"MSFlash"); hFlash = OpenStore(L"DSK0:"); What is the difference between these two sentences? Why can I only use the first sentence in the case of multi-bin, but only the second se...
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
For healthcare professionals, accurate diagnosis and treatment are crucial for a clear picture of a person's health. However, healthcare professionals often rely on tests at medical facilities, cli...[Details]
Gross profit margin jumped from 13.6% in the first half of last year to 25.9%, almost doubling year-on-year.
On August 21, RoboSense released its interim performance report, in which the...[Details]
On August 21st, Zhiyuan Robotics revealed at its first partner conference that it expects shipments to reach thousands of units this year and tens of thousands next year. The company hopes to reach...[Details]
On August 22, South Korean media Nate reported on the 20th local time that Samsung Electronics is introducing Hyper Cell technology into its most advanced 2nm process technology, striving to improv...[Details]
With the increasing number of new energy vehicles on the road, the deployment of supporting facilities for these vehicles has accelerated, and new energy vehicles have gradually entered the vision ...[Details]
Based on the commutation technology, thyristor rectifiers are classified into two main types. Line-commutated and force-commutated inverters are commonly used, while other commutated inverters, nam...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
PowiGaN achieves 95% efficiency at both light and full loads, meeting critical operational and safety requirements.
DARWIN, Australia and SAN JOSE, Calif.,
August 22, 2025 – Powe...[Details]
1. Fault phenomenon and cause analysis
1. During the operation of the equipment, the expansion sleeve is subjected to a large torque, and the mating surfaces of the shaft and the sleeve move...[Details]
Compared to cloud databases, minicomputers are purpose-built for decentralized, rugged computing at the edge of the network. By moving applications, analytics, and processing services closer to the...[Details]
According to Nikkei, a survey found that global electric vehicle battery supply is expected to reach more than three times the required quantity due to
cooling
demand for electric vehicles,...[Details]
Tiantai Robot's official Weibo account announced on the evening of August 20 that Tiantai Robot Co., Ltd., together with strategic partners including Shandong Future Robot Technology Co., Ltd., Sha...[Details]
In the field of communications power supplies, AC/DC rectifier power supplies are called primary power supplies or basic power supplies, while DC/DC converters are called secondary power supplies. ...[Details]