EEWORLDEEWORLDEEWORLD

Part Number

Search

13GK03613

Description
Interconnection Device,
CategoryThe connector    The connector   
File Size175KB,2 Pages
ManufacturerSwitchcraft
Download Datasheet Parametric View All

13GK03613 Overview

Interconnection Device,

13GK03613 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Other featuresPLUG, RIGID PLASTIC
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
The text read out using CEDIT can be displayed, but when dragging the scroll bar, the text overlaps. When these words are selected and refreshed, the overlap disappears. How can I solve this problem?
The text read out using CEDIT can be displayed, but when dragging the scroll bar, the text overlaps. When these words are selected and refreshed, the overlap disappears. How can I solve this problem?...
miaoer Embedded System
TMS320F28335ADC Detailed Explanation
The TMS320F28335 contains a 12-bit AD converter with the following features: 12-bit ADC core with built-in (sample and hold) S/H Analog input: 0.0V to 3.0V (voltages above 3.0V produce full-scale conv...
灞波儿奔 Microcontroller MCU
How to analyze whether flash data transmission is normal
Hello everyone, there is a batch product error. After replacing the new batch of flash, the function is normal. How can I determine that the flash has failed and is abnormal in hardware? How can I vie...
youn@g Analog electronics
Phase-Shifted Zero-Voltage Soft-Switching Converter and Application of UC3875
Abstract: This paper introduces the development process and main development direction of switching power supplies, focusing on the working principle and process of phase-shifted soft-switching conver...
zbz0529 Energy Infrastructure?
Design rules for four-layer PCB
In the design of PCB multi-layer boards, four-layer boards are generally used more. So, do you know what are the design rules of PCB four-layer boards?1. Design of four-layer board:(1) Uniform spacing...
就某个水呀 PCB Design
[stm32 timer] From ST's motor library, I don't understand its meaning
I would like to ask the engineers a question. I saw such a configuration in the STM32 timer [code] TIM_SelectOutputTrigger(TIM1, TIM_TRGOSource_Update); Use the UPDATE event as the trigger output // T...
jonny0811 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 999  2288  1297  2117  2039  21  47  27  43  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号