EEWORLDEEWORLDEEWORLD

Part Number

Search

177-710-1-31GP4J5-24RNN

Description
Interconnection Device,
CategoryThe connector    The connector   
File Size436KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

177-710-1-31GP4J5-24RNN Overview

Interconnection Device,

177-710-1-31GP4J5-24RNN Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Code_compli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
MWDM Micro-D Shielded Cable Assemblies
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly
labor. 100% tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair
177-740 cables are furnished with a full complement of
white/blue twisted pair wires.
Integral Shield Termination–The
connector shell has a
platform to accept Band-It shield termination bands. The
cable shield braid is attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding with
Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s fully
shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-piece connector
shell and secured with a stainless steel
BAND-IT
® clamp. These pre-wired, 100% tested assemblies meet the
requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low shell-to-shell resistance.
Available with a variety of wire types and shields, Micro-D shielded assemblies can be ordered in any length, either
single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
– A gold-plated
stainless steel ground spring on the pin connector mating face offers
substantial improvement in EMI protection. The graphs compare
identical connectors tested with and without ground springs.
EMI Performance with Ground Spring
SHIELDING EFFECTIVENESS (DB)
SHIELDING EFFECTIVENESS (DB)
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
EMI Performance without Ground Spring
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
FREQUENCY (Hz)
FREQUENCY (Hz)
© 2006 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
B-8
E-Mail: sales@glenair.com
The program can be debugged and run on the device, why can't it be debugged and run on the memory card?
I need to port a WinCE4.0 program to WinCE5.0. It was originally developed under EVC. But if I compile it directly, the program runs slowly on the device. I can't find the reason. I want to try it wit...
hh305 Embedded System
Analysis of Capacitance and Resistance Changes Caused by PCB Layout
Today's electronic products are being developed in an increasingly miniaturized manner, with boards becoming smaller and more sophisticated. For general digital circuits, the size of the board is dete...
buildele PCB Design
Design of digital adjustable high voltage DC regulated power supply
Introduction High voltage power supply is an indispensable part of nuclear radiation detection instruments. It supplies high voltage to nuclear radiation detection devices (such as proportional counte...
songbo Power technology
Independent buttons affect the digital tube display
Hello everyone, I am a junior who has just learned 51. Recently, I have made something similar to a competition stopwatch. Now I have encountered some problems and would like to ask for help. Use time...
云杰 51mcu
The boot0 pull-down voltage of STM32F103VCT6 is 1.0v
Using a 4.7k resistor to pull down boot0, the voltage measured by a multimeter is 1.0v, and boot1 is also pulled down by 4.7k, the voltage is 0V.Replacing boot0's 4.7k with 1k has basically no change ...
fuqiang stm32/stm8
[Project Discussion] [FPGA Learning Series—How to Configure the Program]
I am a beginner. For beginners, I will briefly talk about the three points about FPGA program configuration that we are most concerned about and must understand. 1. Where is the FPGA program stored? L...
ltbytyn FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1058  1290  1955  273  1739  22  26  40  6  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号