GUS-SL8A-01-3012-DB

Description
Array/Network Resistor, Isolated, Tantalum Nitride/nickel Chrome, 0.1W, 30100ohm, 100V, 0.5% +/-Tol, -100,100ppm/Cel, 4030,
CategoryPassive components    The resistor   
File Size277KB,4 Pages
ManufacturerTT Electronics plc
Websitehttp://www.ttelectronics.com/
Download Datasheet Parametric View All

GUS-SL8A-01-3012-DB Overview

Array/Network Resistor, Isolated, Tantalum Nitride/nickel Chrome, 0.1W, 30100ohm, 100V, 0.5% +/-Tol, -100,100ppm/Cel, 4030,

GUS-SL8A-01-3012-DB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid934008767
Reach Compliance Codecompliant
Country Of OriginUSA
ECCN codeEAR99
YTEOL5.36
structureMiniature
JESD-609 codee0
Network TypeIsolated
Number of terminals16
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package height2.54 mm
Package length10.211 mm
Package formSMT
Package width7.493 mm
method of packingTR
Rated power dissipation(P)0.1 W
resistance30100 Ω
Resistor typeARRAY/NETWORK RESISTOR
seriesSOIC
size code4030
technologyTANTALUM NITRIDE/NICKEL CHROME
Temperature Coefficient100 ppm/°C
Terminal surfaceTin/Lead (Sn/Pb)
Tolerance0.5%
Operating Voltage100 V
Surface Mount SOIC
Resistor Networks
SOIC Series
Tested for COTS applications
Both narrow and wide body versions available
Standard JEDEC 8, 14, 16, and 20 pin packages
Ultra-stable TaNSil
®
resistors on silicon substrates
RoHS compliant and Sn/Pb terminations available
IRC’s TaNSil
®
SOIC resistor networks are the perfect solution for high volume applications that demand a small
wiring board footprint. The .050" lead spacing provides higher lead density, increased component count,
lower resistor cost, and high reliability.
The tantalum nitride film system on silicon provides precision tolerance, exceptional TCR tracking, low cost
and miniature package. Excellent performance in harsh, humid environments is a trademark of IRC’s self-pas-
sivating TaNSil
®
resistor film.
The SOIC series is ideally suited for the latest surface mount assembly techniques and each lead can be
100% visually inspected. The compliant gull wing leads relieve thermal expansion and contraction stresses
created by soldering and temperature excursions.
For applications requiring high performance resistor networks in a low cost, surface mount package, specify
IRC SOIC resistor networks.
Electrical Data
Resistance Range
Absolute Tolerance
Ratio Tolerance to R1
Absolute TCR
Tracking TCR
Element Power Rating @ 70°C
Isolated Schematic
Bussed Schematic
Power Rating @ 70°C
SOIC-N Package
Power Rating @ 70°C
SOIC-W Package
Rated Operating Voltage
________________
Operating Temperature
Noise
(not to exceed
Power X Resistance)
10
250KΩ
To ±0.1%
To ±0.05%
To ±25ppm/°C
To ±5ppm/°C
100mW
50mW
8-Pin
14-Pin
16-Pin
16-Pin
20-Pin
400mW
700mW
800mW
1.2W
1.5W
Environmental Data
Test Per
MIL-PRF-83401
Thermal Shock
Power
Conditioning
High Temperature
Exposure
Short-time
Overload
Low Temperature
Storage
Life
Typical
Delta R
±0.02%
±0.03%
±0.03%
±0.02%
±0.03%
±0.05%
Max
Delta R
±0.1%
±0.1%
±0.05%
±0.05%
±0.05%
±2.0%
100 Volts
-55°C to +125°C
<-30dB
General Note
IRC reserves the right to make changes in product specification without notice or liability.
All information is subject to IRC’s own data and is considered accurate at time of going to print.
© IRC Advanced Film Division
• 4222 South Staples Street • Corpus Christi Texas 78411 USA
Telephone: 361 992 7900 • Facsimile: 361 992 3377 • Website: www.irctt.com
A subsidiary of
TT electronics plc
SOIC Series Issue January 2009 Sheet 1 of 4
Poll: What operating system are you using now? (Thank you for participating)
[i=s] This post was last edited by lcofjp on 2017-10-15 15:39 [/i] I am currently writing a serial port application software, which is mainly for electricians. However, this software does not support ...
lcofjp Embedded System
Findfirstfile traversal file problem
I found an example online. It always has to check strcmp(fd.cFileName, ".") && strcmp(fd.cFileName, ".."). What is this used to judge?...
heeroz Embedded System
SYMBOL data collector (MC1000) crash problem
Hello everyone, my question is, why does the MC1000 program I made freeze after scanning about 10 bars? What caused the error? I'm offering RMB 200 to seek the answer. If anyone knows or can solve my ...
szgaoju Embedded System
ADS1291 is used as the ECG acquisition and conversion front end, and the data conversion problems encountered
Recently, I am working on an ECG data acquisition project, using ADS1291 as an analog-to-digital converter. During the test, I found that there is a problem with the converted data: After the analog E...
Maxweller_Wang TI Technology Forum
Today is a special day
Today is a special day. One thing is that I met an online friend of mine for 6 or 7 years (never met in person). We have been in touch on QQ before and both work in Beijing. We have always wanted to g...
wateras1 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2567  558  1958  512  2248  52  12  40  11  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号