Municipal, Industrial and Environmental Applications
LT 5 & 7 Pressure Transducers are non-submersible hydrostatic pressure
transducers specifically designed for demanding industrial applications
where the primary criteria are reliability and economy.
Applications
Non-Submersible Tank Level
Liquid Line Pressure
Pump Control
Construction Bypass Pumping
Dewatering
Features
Standard
0.25% FSO Accuracy
316 Stainless Steel Body
One Year Warranty
Pre-calibrated Pressure Ranges
Optional
0.10% FSO Accuracy
Titanium Body
Two Year Warranty
Custom Pressure Ranges
Intrinsically Safe
Lightning Protection
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 1
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Specifications
STATIC PERFORMANCE
Static Accuracy
(combined effects of non-linearity,
hysteresis and repeatability, best fit
straight line method)
Standard - 0.25% FSO
Optional - 0.10% FSO
+0.0001% FS
316 SS or Titanium; FKM;
Polyurethane or ETFE
0 to 50ºC
±0.1% FSO/ºC
-20 to 60 ºC
IP 68, NEMA 6P
BFSL method
For absolute/sealed reference min. range 0-15 PSI
Resolution
ENVIRONMENTAL
Wetted Materials
Compensated Temp Range
Thermal Error
(maximum allowable deviation from the
Best Fit Straight Line due to a change in
temperature)
Operating Temp Range
Protection Rating
When attached to polyurethane cable
Only for Electrical Connection options “A” & “D”
with Cable Type option “A”; or Electrical
Connection options “B” & “F” with Cable Type option “B”
0-5V, 0-2.5V, 0-4V
4-20
0-10V
1.5-7.5V
For mA output, for VDC output
For ranges < 5 ft. (1.5m) H
2
O,
only 4-20mA output is available
ELECTRICAL
Excitation
9-28V
–
VDC output
9-28V
–
mA output
15-28V
–
VDC output
10-28V
–
VDC output
20 mA max, 3.5 mA max
Standard - 4-20mA
Optional - 0-4 VDC, 0-5 VDC,
0-2.5 VDC, 0-10 VDC, 1.5-7.5 VDC
±0.25 mA for mA output
< 0.25 VDC for VDC output
See loop diagram for mA output
20 ohm for VDC output
100 mega ohm at 50 VDC
Polarity, surge/shorted output
Standard
–
WEEE/RoHS, CE
compliant
Optional
–
UL, CUL, and FM
PHYSICAL
Approximate Weight
Cable Jacket Material
Cable Pull Strength
Cable Number of Conductors
Cable Conductor Size
Cable Seal
0.44 lbs. (198 g) transducer
0.05 lbs./ft. (79 g/m) cable
PVC Jacket, Standard - Polyurethane
Optional - ETFE
200 lbs. (90 kg)
4
22 AWG
Molded Polyurethane
FKM Gland
For polyurethane cable
For ETFE cable
EN 61326-1:2013 and 61326-2-3:2013
Waste from Electrical and Electronic Equipment
(WEEE) and Restrictions on the use of Hazardous
Substances (RoHS)
Class I, II, III, Div. 1, Groups A,B,C,D,E,F,&G
Input Current
Output
Zero Offset
Output Impedance
Insulation Resistance
Circuit Protection
CERTIFICATIONS
LIGHTNING PROTECTION
(power supply needs to be limited to 150mA to avoid lock up of the gas tube after a suppression event)
>1,000 Operations
Life Expectancy
Peak Clamping Voltage
Response Time
Shunts
36 Volts
<10 nsecs
20,000 Amperes
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 2
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Dimensions
Electrical Termination / Loop Resistance
ELECTRICAL TERMINATION
22AWG CONDUCTORS IN A SHIELDED CABLE WITH VENT TUBE
4-20 mA
0-5 VDC
ALL
RED
BLACK
RED
BLACK
WHITE
DRAIN WIRE
+ EXCITATION
- EXCITATION
+ EXCITATION
- EXCITATION
+ SIGNAL
SHIELD
Standard Pressure Ranges for 0.25% Accuracy
Pressure Range
3
5
5
3
5
3
5
7
9
LT 5, 7 Vented
X
X
X
X
X
X
X
X
N/A
N/A
N/A
axi u
of 3
LT 5, 7 Sealed
N/A
N/A
X
X
X
X
X
X
X
X
X
PSI. Mi i u
LT 5,7 Absolute
N/A
N/A
N/A
X
X
X
X
X
X
X
X
NOTE: O er old optio is li ited to a
sealed/a solute refere e is - 5 PSI
ra ge for +/- .
% ith
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 3
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Ordering Information
TRANSDUCER
L
T Submersible Level Transducer
↓
↓
PRESSURE PORT
5
¼” –
18 Male NPT Fitting
7
½” –
14 Male NPT Fitting
↓
OUTPUT
8
4
–
20 mA
1
0
–
2.5 VDC
2
0
–
4 VDC
3
0
–
5 VDC
4
0
–
10 VDC
5
1.5
–
7.5 VDC
G
4-20 mA w/Lightning
A
0-2.5 VDC w/Lightning
B
0-4 VDC w/Lightning
C
0-5 VDC w/Lightning
D
0-10 VDC w/Lightning
E
1.5-7.5 VDC w/Lightning
↓
CABLE TYPE
A
Polyurethane
B
ETFE
C
PVC jacket
↓
ACCURACY
B
±0.25% FSO
R
±0.25% FSO with Cal Report
A
±0.10% FSO
S
±0.10% FSO with Cal Report
↓
INTRINSIC SAFETY APPROVALS
B
UL, FM & CUL (Cable Type A, B, or C Only)
D
None
↓
WARRANTY
1
A
Standard one year Warranty
B
Custom label one year Warranty
J
Extended two year Warranty
K
Custom Label extended two year Warranty
↓
MATERIAL
S
Stainless Steel
T
Titanium
↓
ELECTRICAL CONNECTION
A
Overmold (Cable Type A Only)
B
Gland Seal
(Cable Type “A” or “B” Only)
D
Overmold w/ ½” –
14 NPT Conduit (Cable Type A Only)
F
Gland Seal w/ ½” –
14 NPT Conduit
(Cable Type “A” or “B” Only)
1
Strain-relieved cable with flying leads - standard (Cable Type C Only)
2
PVC conduit strain relief
(Cable Type C Only)
↓
PRESSURE RANGE
x
x
x
Refer to chart page 4
↓
↓
↓
LABEL UNITS
P
PSI M mH2O F Ft. H2O
↓
PRESSURE REFERENCE
A
Absolute
G
Vented Gage
S
Sealed Gage
↓
CABLE LENGTH (FT)
x
x
x
Cable length in feet
↓
↓
↓
L
T
1
Contact Measurement Specialties if private labeling is required.
NORTH AMERICA
Measurement Specialties, Inc.
a TE Connectivity Company
Tel 800-522-6752
customercare.hmpt@te.com
EUROPE
Measurement Specialties (Europe), Ltd.,
A TE Connectivity Company
Tel 800-440-5100
customercare.dtmd@te.com
ASIA
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Tel 0400-820-6049
customercare.shzn@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties (MEAS), American Sensor Technologies (AST), TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products
and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no
warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and
Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product.
Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
[i=s]This post was last edited by paulhyde on 2014-9-15 09:03[/i] I feel that DSP is very difficult, but our instructor asked us to learn about this chip. I am really confused and would like some advi...
I changed the pin definition but it still doesn't work, and then I connected the ground wire. I tried adding a power supply but it still didn't solve the problem. I hope someone can give me some advic...
When downloading the image in PB, if you choose to go through ethernet, does the communication between the PC and the target machine rely on the TCP/IP protocol or through KITL?...
[table] [tr][td] Hello everyone, it's time for daily learning again. Today we will talk about how to burn bin format files into flash using FPGA design and operation software vivado. 1. Click bitstrea...
I am currently working on a sensor project. The load capacity and distance of the RS485 communication are not satisfactory. I found a chip called PB620. The manual says 256 slave nodes and 3000m dista...
Everyone: After rtw compilation, the model .lo obtained by simulation under vxworks always cannot find a function in rt_main: rt_ODEUpdateCouinousState. Why is this? Please help me with some advice....
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
Microcontrollers (MCUs), which are widely used in automotive electronics, are rapidly facing time and cost pressures. The main advantage of using MCUs has always been to create high-level system in...[Details]
With the continuous improvement of the requirements of intelligent building security systems and the continuous improvement of people's safety awareness, indoor anti-theft has gradually attracted peop...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
LED technology has made rapid progress, and improvements in chip design and materials have promoted the development of brighter and more durable light sources, and the scope of light source applica...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]
A stepper motor is an electromagnetic mechanical device that converts an electrical pulse signal into an angular displacement or a linear displacement. The stability and reliability of a stepper mo...[Details]
1 Battery technology determines the fate of energy vehicles
Regardless of whether new energy vehicles are hybrid or pure electric vehicles, they cannot do without the core technology of batter...[Details]
Don’t just look at the power when choosing a power supply
We know that a power supply with a low rated power can hardly meet the power supply needs of the system, which may cause frequent free...[Details]