EEWORLDEEWORLDEEWORLD

Part Number

Search

31743

Description
choke 12a - 1000uh
CategoryAnalog mixed-signal IC    filter   
File Size118KB,1 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

31743 Online Shopping

Suppliers Part Number Price MOQ In stock  
31743 - - View Buy Now

31743 Overview

choke 12a - 1000uh

31743 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerVICOR
package instructionROHS COMPLIANT PACKAGE-4
Reach Compliance Codecompliant
ECCN codeEAR99
Maximum DC resistance6.5 Ω
filter typeDATA LINE FILTER
high0.8 mm
inductance1000 µH
length1.16 mm
Installation typeTHROUGH HOLE MOUNT
Number of functions2
physical sizeL1.16XB0.97XH0.8 (mm)/L0.046XB0.038XH0.031 (inch)
Rated current12 A
width0.97 mm
Base Number Matches1
8
VICOR CONFIDENTIAL
7
6
5
4
3
2
1
F
THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR
HEREWITH IS NOT TO BE REPRODUCED, USED OR
DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT
THE PERMISSION OF VICOR CORP.
REVISIONS
REV
.97
2
3
1
1
2
3
4
DESCRIPTION
RELEASED PER E060499
REVISED PER E063650
REVISED PER E060905
REVISED PER E072040
REVISED PER E091875
REVISED PER E092163
REVISED PER E101309
DATE
PEI 02/16/06
PEI 03/13/06
BW 07/28/06
JS
JS
09/06/07
10/20/09
APPROVED
MB
MB
MB
SG
REJH
MH
AR
E
F
E
3
5
4
1
SEE NOTE 7
2
5
1.16
6
7
GCK 12/04/09
KUK 10/22/10
REF:
ISOLATION INSULATOR (FR4)
SEE NOTES 5 & 7
5
D
2
D
1.058 MAX
.125
4
WIRE GAUGE TABLE
REF. - ISOLATION INSULATOR
(FR4) - SEE NOTE 5
A
PN#
31741
WIRE GAUGE
#21
#19
#16
#16
PIN DIAMETER AFTER
TINNING (+/-.003")
.805 MAX
C
0.030"
0.036"
0.051"
0.051"
C
A
.065
SEE NOTE 9
1.00
(LEAD SPACING MEASURED AT DATUM A)
.38
MAX
.25
MIN
31742
31743
31744
NO EXPOSED INSULATION
OR COPPER
.60
(LEAD SPACING MEASURED AT DATUM A)
B
A
MARK THIS SURFACE WITH
NOTES:
PART NO., & DATE CODE
1. ASSEMBLY TO BE FREE OF NICKS.
2. WINDINGS TO BE EVENLY SPACED.
3. RoHS COMPLIANT. LEAD FREE PER CST-0001 LATEST REVISION.
4. GENERAL WORKMANSHIP STANDARDS FOR MAGNETIC COMPONENTS PER WS-0002.
5. ITEMS 3 & 4 SUPPLIED BY VENDOR AT ASSEMBLY.
6. ALL PARTS FLAME RATED MIN U.L. 94V-0.
MATERIAL
7. APPLY ADHESIVE (ITEM 5) TO THE BASE OF ISOLATION INSULATOR (ITEM 3) AND TO ALL LEADS ON
SEE NOTES
THE TOP SURFACE OF THE BOARD.
8. DENOTES CRITICAL CHARACTERISTIC FOR LOT INSPECTION.
9. SEE TABLE FOR WIRE GAUGE DIMENSIONS.
FINISH
10. LEADS MAY BE TINNED WITH SN96/AG4 OR SAC305 (SN 96.5, AG 3.0, CU 0.5) OR VICOR APPROVED
SEE NOTES
EQUIVALENT.
11. DIMENSONS ARE INCHES ONLY.
8
7
6
5
4
B
DRAWN
P.E.IENI
DATE
11/02/05
VICOR
SWD
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE INCH [MM]
TOLERANCES ARE:
DECIMALS
ANGLES
X.XX [X.X] = ±0.01 [0.25]
±1°
X.XXX [X.XX] = ±0.005 [0.127]
THIRD ANGLE PROJECTION
IND TOR 1.03 DIA 2W
ASSY DWG
SIZE
CAGE CODE
DWG NO
REV
B
DO NOT SCALE DRAWING
67131
2
31895
SHEET 1 OF 1
7
1
A
SCALE 2 : 1
3

31743 Related Products

31743 31742
Description choke 12a - 1000uh choke 7A - 3000uh
It is said that the MSP430 microcontroller can blow the fuse? Can an expert guide me how to do it?
Is the fuse integrated into the microcontroller?How to blow the fuse? What kind of circuit is needed?Or does it need to be implemented during programming?Please give me some advice, thank you....
qq66847958 Microcontroller MCU
What is RTC clock sync with RTC_APB1 clock? ?
What does the underlined part mean? ? ? ?...
electrics stm32/stm8
Rethinking 5G
Recently, I read the book " Popular Science: Re-understanding 5G " released by QORVO and gained a lot. Here is the main content. Since the advent of 5G, the conversation has focused primarily on three...
alan000345 RF/Wirelessly
How to operate IO under XP, please give me some ideas
My industrial computer is installed with XP system, which needs a watchdog, so my program needs to operate IO, but XP does not allow applications to directly operate IO! What should I do? Please give ...
outblue Embedded System
MSP430 Program Library--Use of DAC12
The DAC12 module of MSP430 can convert the result of operation processing into analog quantity to operate the working process of the controlled object. DA is one of the commonly used devices in the co...
fish001 Microcontroller MCU
Precision rectification is not precise
As shown in the attached circuit and parameters, when I_in reaches 1.8V, it cannot coincide with the I_in+ half axis. The average value of the 50hz AC signal and the oscilloscope's measurement functio...
呜呼哀哉 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 651  457  732  1190  2736  14  10  15  24  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号