FG*: Straight plug, cable collet and nut for fitting a bend relief
1 key (alpha=0, plug: male contacts, receptacle: female contacts)
Brass (chrome plated) shell and collet nut, nickel plated brass latch sleeve and mid pieces
D52: 4.3 - 5.2 mm
Z : Nut for fitting a bend relief
29.81 g
Performance
Configuration
Insulator
Rated Current
2B.312 : 12 Low Voltage
L: PEEK (UL 94 / V-0/3.2, depends on material thickness)
7 Amps
Specifications
Contact Type: Solder
Max. Matings: 5000
LEMO products and services are provided “as is”. LEMO makes no warranties or representations with regard to LEMO product & services or use of
them, express, implied or statutory, including for accuracy, completeness, or security. The user is fully responsible for his products and applications
using LEMO components.
1/3
Contact Dia.: 0.7 mm (0.028in)
Bucket Dia.: 0.8 mm (0.031in)
Max. Stranded Conductor: 0.34 mm^2 (AWG 22)
Max. Conductor: 0.34 mm^2 (AWG 22)
R (max): 6.1 mOhm
Vtest (contact-shell): 1350 V (AC), 1910 V (DC)
Vtest (contact-contact): 1250 V (AC), 1770 V (DC)
Others
Temp (min / max): -55°C / +250°C
Humidity (max): <=95% [at 60 deg C /140 F]
Vibration: 15 g [10 Hz - 2000 Hz]
Shock Resistance: 100 g [ 6 ms]
Salt Spray Corrosion: >1000 hr
Climatical Category: 50/175/21
Shielding (min): 75 dB (10 MHz)
Shielding (min): 40 dB (1 GHz)
IP Rating: 50
DRAWINGS
Draws
Dimensions
A
mm.
in.
15
0,59
L
49
1,93
M
37
1,46
S1
13
0,51
S2
12
0,47
LEMO products and services are provided “as is”. LEMO makes no warranties or representations with regard to LEMO product & services or use of
them, express, implied or statutory, including for accuracy, completeness, or security. The user is fully responsible for his products and applications
using LEMO components.
2/3
RECOMMENDED BY LEMO
Tools
Spanner wrench: MTZ.2B.220.120
Caps: BFG.2B.100.PCSG
Cables
012 050
PVC
Black
LEMO products and services are provided “as is”. LEMO makes no warranties or representations with regard to LEMO product & services or use of
them, express, implied or statutory, including for accuracy, completeness, or security. The user is fully responsible for his products and applications
Can a critical section only be used to synchronize processes? That is, only one process can enter the critical section, but several threads can enter the critical section at the same time? Can a mutex...
.\Obj\Object.axf: Error: L6218E: Undefined symbol __BASEPRICONFIG (referred from stm32f10x_nvic.o).
.\Obj\Object.axf: Error: L6218E: Undefined symbol __GetBASEPRI (referred from stm32f10x_nvic.o).
.\O...
My friend's company is hiring people who are familiar with C/VC++, and have a college or bachelor's degree, regardless of major. If you are interested, please send your resume to comey@163.com, and I ...