EEWORLDEEWORLDEEWORLD

Part Number

Search

2027-60-B10

Description
Surge Protection Circuit,
CategoryWireless rf/communication    Telecom circuit   
File Size161KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2027-60-B10 Overview

Surge Protection Circuit,

2027-60-B10 Parametric

Parameter NameAttribute value
MakerBourns
package instruction,
Reach Compliance Codeunknown
JESD-30 codeX-XXSS-X2
Number of functions1
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
8 mm diameter, 6 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2027 Series - 2-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Model No.
2027-20
200 V
400 V
600 V
Characteristic
DC Sparkover ±15 %
(±20 % for Models 2027-07 & 2027-09) @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
2027-07
75 V
300 V
500 V
2027-09
90 V
300 V
500 V
2027-15
150 V
350 V
575 V
2027-23
230 V
450 V
675 V
2027-25
250 V
475 V
700 V
2027-30
300 V
550 V
800 V
2027-35
350 V
600 V
875 V
Model No.
2027-40
2027-42
400 V
420 V
650 V
925 V
675 V
950 V
2027-47
470 V
725 V
1000 V
2027-60
600 V
850 V
1100 V
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance .........................100 V (50 V for Models 2027-07 and 2027–09) ..................... > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................> 1A ........................................................................................ ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
(2)
......................135 V, (52 V for Models 2027-07 and 2027-09,
80 V for Model 2027-15) ........................................................ < 150 ms
Impulse Discharge Current .................25000 A, 8/20
μs
(3)
................................................................. 1 operation minimum
10000 A, 8/20
μs
.................................................................... > 10 operations
2500 A, 10/350
μs
.................................................................. 2 operations
500 A, 10/1000
μs
................................................................. > 400 operations
100 A, 10/1000
μs
or 10/700
μs
............................................. > 1000 operations
Alternating Discharge Current ............65 Arms, 11 cycles
(3)
.............................................................. 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature....................................................................................................................... -55 to +125 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Moisture Sensitivity Level .................................................................................................................. 1
ESD Classification (HBM) .................................................................................................................. 6
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 27-xxxV.
• Sparkover limits ±20 % after life, IR >10
8
Ω
(-25 %, +30 % for Models 2027-07, 2027–09 and 2027–60).
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±20 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
How is medical device design continuing to advance the transition from hospital-based healthcare to home healthcare?
[i=s]This post was last edited by dontium on 2015-1-23 13:17[/i]By Steven A Dean , Director of Medical Product Marketing, Texas InstrumentsIn 2009 , we expect the scattered pieces of this ecosystem pu...
德州仪器 Analogue and Mixed Signal
Help: cc2430 driver ds18b20 problem
Has anyone done a wireless temperature measurement project based on Zigbee wireless network technology using the cc2430 development board and ds18b20 temperature sensor? I am working on it, but I have...
wwh19910609 RF/Wirelessly
I didn’t receive the launchPad, but I received a FRAM development board.
I don’t know what’s going on?...
campo Microcontroller MCU
GPS Positioning System
I want to use 430 to make a receiver for GPS positioning system, and I'm looking for some advice from seniors who have experience in this field. . ....
lindandaixu NXP MCU
Timer/Counter Mode Control Word
From the previous section, we have learned that the timer/counter in the microcontroller can have multiple uses, so how can I make them work for the purpose I need? This requires setting the timer/cou...
rain MCU
Discussion on the processing method of negative numbers in FPGA
FPGA programming generally involves timing design and other logic circuits, but if FPGA is used for data processing operations, it may involve the processing of negative numbers. For example, if an AD...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 925  1585  784  1797  1528  19  32  16  37  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号