economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 500 VAC ±10%
50 Hz ±1 Hz
1.1 to 250 kW
<5% at rated power
>98% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00, IP 20
Internal fan cooling or external cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
+45°C to +70°C derated operation***
–25°C to +85°C transport and storage
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
>200,000 hours
100 kA
TN, TT, IT
OV III (IEC 60664-1 / UL 61800-5-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
MTBF @ 45°C/500 V (Mil-HB-217F)
SCCR****
Earthing System
Overvoltage category
****System requirements: THVD <2%, line voltage unbalance <1%
** *
Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****SCR
rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
THID ~5% at rated power for filter <6 kW
** Please check the inlet air flow required for cooling table on page 6 of this document.
*** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√(70°C-T
amb
)/25°C
**** External UL-rated fuses required. Please consult the user manual.
2
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 00 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E0_ _ _ _ _*
FN 3450-2-110-E0_ _ _ _ _*
FN 3450-4-112-E0_ _ _ _ _*
FN 3450-6-112-E0_ _ _ _ _*
FN 3450-8-112-E0_ _ _ _ _*
FN 3450-11-112-E0_ _ _ _ _*
FN 3450-15-113-E0_ _ _ _ _
FN 3450-19-113-E0_ _ _ _ _
FN 3450-22-113-E0_ _ _ _ _
FN 3450-30-115-E0_ _ _ _ _
FN 3450-37-115-E0_ _ _ _ _
FN 3450-45-115-E0_ _ _ _ _
FN 3450-55-115-E0_ _ _ _ _
FN 3450-75-115-E0_ _ _ _ _
FN 3450-90-116-E0_ _ _ _ _
FN 3450-110-116-E0_ _ _ _ _
FN 3450-132-118-E0_ _ _ _ _
FN 3450-160-118-E0_ _ _ _ _**
FN 3450-200-118-E0_ _ _ _ _**
FN 3450-250-118-E0_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
5.8
8.4
11.3
14.0
16.9
20.9
28.2
32.0
36.0
47.5
53.9
63.1
66.8
88.1
120.1
140.6
160.9
181.1
216.8
256.7
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
3
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 20 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E2_ _ _ _ _*
FN 3450-2-110-E2_ _ _ _ _*
FN 3450-4-112-E2_ _ _ _ _*
FN 3450-6-112-E2_ _ _ _ _*
FN 3450-8-112-E2_ _ _ _ _*
FN 3450-11-112-E2_ _ _ _ _*
FN 3450-15-113-E2_ _ _ _ _
FN 3450-19-113-E2_ _ _ _ _
FN 3450-22-113-E2_ _ _ _ _
FN 3450-30-115-E2_ _ _ _ _
FN 3450-37-115-E2_ _ _ _ _
FN 3450-45-115-E2_ _ _ _ _
FN 3450-55-115-E2_ _ _ _ _
FN 3450-75-115-E2_ _ _ _ _
FN 3450-90-116-E2_ _ _ _ _
FN 3450-110-116-E2_ _ _ _ _
FN 3450-132-118-E2_ _ _ _ _
FN 3450-160-118-E2_ _ _ _ _**
FN 3450-200-118-E2_ _ _ _ _**
FN 3450-250-118-E2_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
7
9
13
15
19
23
32
36
40
53
60
69
74
95
129
149
178
198
234
274
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
4
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Product selector
Table 1: Filter configurations if external air flow is available for cooling
(Filters do
not contain fan
and do
not contain aux. power supply)
E0XXXXX
- For rectifiers without DC-link
choke
E0XXJXX
- For rectifiers without DC-link
choke
- Filters contain trap disconnect
jumper
E0XXXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module
E0XXJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module and trap disconnect
jumper
5
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Table 2: Filter configurations with embedded ventilation
(Filters
contain fan
and
aux. power supply)
E0FAXXX and E2FAXXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply
E0FAJXX and E2FAJXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply and trap disconnect
jumper
E0FAXRX and E2FAXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply and RC damper module
E0FAJRX and E2FAJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply, RC damper module and
trap disconnect jumper
Table 3: Filter configurations if external aux. power supply for the fan is available
stm8L152 controls the forward and reverse rotation of the motor, and the working mode simulates a washing machine. 1. Washing mode: forward rotation for 5s, pause for 2s, reverse rotation for 5s, and ...
Recently, I needed some information about security, so I looked for some websites. Some of them I had visited once or twice before were closed or went out of business. Alas!...
The program cannot be compiled, and the prompt is as follows. What's going on? It can be compiled with the previous version. Is it because of the difference in the compiler? ? ?
Clean: Deleted file "F...
This is my first project using the LM3S8962 chip. Now it’s at the board-making stage. I’d like to share my schematic with the forum. Please give me your comments!...
Some time ago, due to the system reinstallation, orCAD10.3 failed to install several times. I have been using the green version, but after all, some functions are not complete. I want to switch to the...
After inserting a USB flash drive into WinCE5.0, DSK1: USB Hard Disk Driver can be seen in Storage Manager, but no Hard Disk drive letter appears. However, when I format the inserted USB flash drive a...
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
introduction
For the voltage regulator modules (VRMs) that power the latest computer central processing units (CPUs), power supply designers have historically used multiphase interleaved b...[Details]
0 Introduction
With the development of society, people pay more and more attention to security work. Monitoring products have been used in various fields instead of being used only in importan...[Details]
1 Introduction
In recent years, there have been many major advances in the production technology and processes of automotive headlights, which have greatly improved the performance of automoti...[Details]
Different initialization between C8051F and 80C51 series microcontrollers
In the past 30 years, major electronic component manufacturers in the world have launched their own unique single-chip...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
Overview
By transmitting ultrasonic energy into the human body and receiving and processing the returning reflected signals, phased array ultrasound systems can generate images of organs and s...[Details]
Almost everyone in a student dormitory has a bedside lamp. But if you want to read for a while after turning off the lights and don't want to disturb your roommates' sleep, you may need a reading l...[Details]
The fluorescent lamps and energy-saving lamps we commonly use now have greatly improved luminous efficiency compared with the earlier ordinary incandescent lamps and have been widely used. With the...[Details]
Today, with the increasing integration of functions, mobile phones can also be used as portable media players (PMP), digital cameras, handheld computers (PDAs), and even global positioning systems (GP...[Details]