EEWORLDEEWORLDEEWORLD

Part Number

Search

LD200400

Description
counter 4 digit 2.25" 120vac red
CategoryTopical application    Test and measurement   
File Size1MB,16 Pages
ManufacturerRed Lion Controls, Inc.
Websitehttp://www.redlion.net/
Environmental Compliance  
Download Datasheet Compare View All

LD200400 Overview

counter 4 digit 2.25" 120vac red

Bulletin No. LD-K
Drawing No. LP0607
Released 05/11
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL LD - LARGE DISPLAY
2.25" & 4" HIGH RED LED DIGITS
AVAILABLE IN 4 OR 6 DIGIT VERSIONS
SINGLE OR DUAL COUNTER with RATE INDICATOR
*
PROGRAMMABLE SCALING AND DECIMAL POINTS
*
BUILT-IN BATCH COUNTING CAPABILITY
*
PROGRAMMABLE USER INPUT
*
UNIVERSALLY POWERED
DUAL 5 AMP FORM C RELAY
*
C
UL
R
US LISTED
51EB
ALUMINUM NEMA 4X CASE CONSTRUCTION
* Programmable models only
IND. CONT. EQ.
GENERAL DESCRIPTION
The Large Display is a versatile display that can be configured as a single or
dual counter with rate indication, scaling, serial communications and a dual
relay output. There are also basic models that have a single counter with
direction control only (no scaling or relay output).
The 4 & 6 digit displays are available in either 2.25" or 4" high red LED digits
with adjustable display intensities. The 2.25" high models are readable up to 130
feet. The 4" high models are readable up to 180 feet. All versions are constructed
of a NEMA 4X/IP65 enclosure in light weight aluminum.
The 6-digit programmable models have two signal inputs and a choice of
eight different count modes. These include bi-directional, quadrature and anti-
coincidence counting, as well as a dual counter mode. When programmed as a
dual counter, each counter has separate scaling and decimal point selection.
Rate indication is available on the programmable models only. The rate
indicator has separate scaling and decimal point selection, along with
programmable display update times. The meter display can be toggled either
manually or automatically between the count and rate values.
The programmable models also come with a dual Form C relay output and
RS232 or RS485 serial communications. The outputs can activate based on
either counter or rate setpoint values. An internal batch counter can be used to
count setpoint output activations.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
SPECIFICATIONS
1.
DISPLAY:
2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED
2.
POWER REQUIREMENTS:
AC POWER: 50 to 250 VAC 50/60 Hz, 26 VA
DC POWER: 21.6 to 250 VDC, 11 W
DC OUT: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC
+24 VDC @ 50 mA if input voltage is less than 50 VDC
Isolation: 2300 V
RMS
for 1 min. to all inputs and outputs
3.
COUNT INPUT(S):
Counter(s) have DIP switch selectable pull-up (7.8 K) or pull-down
resistors (3.9 K) that determine active high or active low input logic.
Counters are DIP switch selectable for high or low frequency (Damping
capacitor provided for switch contact bounce. Limits input frequency to 50
Hz and input pulse widths to 10 msec min.)
Input A Trigger levels: V
IL
= 1.25 V max; V
IH
= 2.75 V min; V
MAX
= 28 VDC
Input B Trigger levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Overflow Indication: Display “

” alternates with overflowed count value.
LD200400, LD200600, LD400400, & LD400600:
Count Rate: 25 KHz max. @ 50% duty cycle (no scaling)
LD2006P0 & LD4006P0:
Maximum Count Rates:
50% duty cycle, count mode dependent.
With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 KHz).
With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14
KHz), Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz).
4.
RATE INPUT: Models LD2006P0 & LD4006P0 only
Display Range: 0 to 99999
Min Freq.: 0.01 Hz
Max Freq.: See Count Input specification
Accuracy: ±0.01%
Rate Overflow Indication: Display “

SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected to
it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the unit.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION:
Risk of electric shock.
DIMENSIONS In inches (mm)
X
Z
PART
NUMBER
X (Length)
Y (Height)
Z (Center)
LD2004xx 12 (304.8)
4 (101.6)
4 (101.6)
8 (203.2)
12 (304.3)
Y
LD2006xx 16 (406.4)
LD4004xx 20 (508)
LD4006xx 26 (660.4)
7.875 (200) 16 (406.4)
7.875 (200) 22 (558.8)
AIR PRESSURE STABILIZATION VENT
2.25
(57.15)
1

LD200400 Related Products

LD200400 LD400400 LD200600 LD2006P0 LD4006P0 LD400600
Description counter 4 digit 2.25" 120vac red counter 4 digit 4.0" 120vac red counter 6 digit 2.25" 120vac red counter 6 digit dual 2.25" red counter 6 digit dual 4.0" red counter 6 digit 4.0" 120vac red
Master the various data types in LabVIEW
...
cscl Test/Measurement
The development of smartphones
[p=28, null, left][color=rgb(34, 34, 34)][font="]In the next few years, the general direction of smartphone development will definitely be 5G and AI, especially 5G. In addition to the simple improveme...
maiyoua RF/Wirelessly
[Atria AT32WB415 series Bluetooth BLE 5.0 MCU] Light up in FreeRTOS, all codes, Github long-term update
[i=s]This post was last edited by KING_阿飞 on 2022-8-1 11:29[/i][Atria AT32WB415 series Bluetooth BLE 5.0 MCU] Light up in FreeRTOS, all codes, Github long-term update I am honored to have the opportun...
KING_阿飞 RF/Wirelessly
Xiaoqiang and Xiaoming—>>—A story that is going viral
[font=宋体][size=6][color=black][b]Xiao Qiang and Xiao Ming >>——A story that is going viral 1. Xiao Qiang wanders around the village every day, and his parents are worried about what they will do with t...
499362154 Talking
The results of hardware simulation and burning program are inconsistent. Is there anything else that I haven’t summarized?
1. Configuration problem: Is the configuration word of the microcontroller the same when actually burning the chip as when emulating? Is it configured correctly during burning? 2. Resource problem: Th...
Jacktang Microcontroller MCU
About the continuous reading problem of IIC
I have never paid much attention to IIC before, but today I found that when I operate the same IIC register address for reading, the values are different. 1. What do you think is the reason? Reading i...
zhuzd Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 735  2466  1150  2706  196  15  50  24  55  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号