LD400400 Overview

counter 4 digit 4.0" 120vac red

Bulletin No. LD-K
Drawing No. LP0607
Released 05/11
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL LD - LARGE DISPLAY
2.25" & 4" HIGH RED LED DIGITS
AVAILABLE IN 4 OR 6 DIGIT VERSIONS
SINGLE OR DUAL COUNTER with RATE INDICATOR
*
PROGRAMMABLE SCALING AND DECIMAL POINTS
*
BUILT-IN BATCH COUNTING CAPABILITY
*
PROGRAMMABLE USER INPUT
*
UNIVERSALLY POWERED
DUAL 5 AMP FORM C RELAY
*
C
UL
R
US LISTED
51EB
ALUMINUM NEMA 4X CASE CONSTRUCTION
* Programmable models only
IND. CONT. EQ.
GENERAL DESCRIPTION
The Large Display is a versatile display that can be configured as a single or
dual counter with rate indication, scaling, serial communications and a dual
relay output. There are also basic models that have a single counter with
direction control only (no scaling or relay output).
The 4 & 6 digit displays are available in either 2.25" or 4" high red LED digits
with adjustable display intensities. The 2.25" high models are readable up to 130
feet. The 4" high models are readable up to 180 feet. All versions are constructed
of a NEMA 4X/IP65 enclosure in light weight aluminum.
The 6-digit programmable models have two signal inputs and a choice of
eight different count modes. These include bi-directional, quadrature and anti-
coincidence counting, as well as a dual counter mode. When programmed as a
dual counter, each counter has separate scaling and decimal point selection.
Rate indication is available on the programmable models only. The rate
indicator has separate scaling and decimal point selection, along with
programmable display update times. The meter display can be toggled either
manually or automatically between the count and rate values.
The programmable models also come with a dual Form C relay output and
RS232 or RS485 serial communications. The outputs can activate based on
either counter or rate setpoint values. An internal batch counter can be used to
count setpoint output activations.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
SPECIFICATIONS
1.
DISPLAY:
2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED
2.
POWER REQUIREMENTS:
AC POWER: 50 to 250 VAC 50/60 Hz, 26 VA
DC POWER: 21.6 to 250 VDC, 11 W
DC OUT: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC
+24 VDC @ 50 mA if input voltage is less than 50 VDC
Isolation: 2300 V
RMS
for 1 min. to all inputs and outputs
3.
COUNT INPUT(S):
Counter(s) have DIP switch selectable pull-up (7.8 K) or pull-down
resistors (3.9 K) that determine active high or active low input logic.
Counters are DIP switch selectable for high or low frequency (Damping
capacitor provided for switch contact bounce. Limits input frequency to 50
Hz and input pulse widths to 10 msec min.)
Input A Trigger levels: V
IL
= 1.25 V max; V
IH
= 2.75 V min; V
MAX
= 28 VDC
Input B Trigger levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Overflow Indication: Display “

” alternates with overflowed count value.
LD200400, LD200600, LD400400, & LD400600:
Count Rate: 25 KHz max. @ 50% duty cycle (no scaling)
LD2006P0 & LD4006P0:
Maximum Count Rates:
50% duty cycle, count mode dependent.
With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 KHz).
With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14
KHz), Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz).
4.
RATE INPUT: Models LD2006P0 & LD4006P0 only
Display Range: 0 to 99999
Min Freq.: 0.01 Hz
Max Freq.: See Count Input specification
Accuracy: ±0.01%
Rate Overflow Indication: Display “

SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected to
it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the unit.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION:
Risk of electric shock.
DIMENSIONS In inches (mm)
X
Z
PART
NUMBER
X (Length)
Y (Height)
Z (Center)
LD2004xx 12 (304.8)
4 (101.6)
4 (101.6)
8 (203.2)
12 (304.3)
Y
LD2006xx 16 (406.4)
LD4004xx 20 (508)
LD4006xx 26 (660.4)
7.875 (200) 16 (406.4)
7.875 (200) 22 (558.8)
AIR PRESSURE STABILIZATION VENT
2.25
(57.15)
1

LD400400 Related Products

LD400400 LD200400 LD200600 LD2006P0 LD4006P0 LD400600
Description counter 4 digit 4.0" 120vac red counter 4 digit 2.25" 120vac red counter 6 digit 2.25" 120vac red counter 6 digit dual 2.25" red counter 6 digit dual 4.0" red counter 6 digit 4.0" 120vac red
About the p1.3 button on the launchpad
I want to use the P1.3 button to realize interrupt control of the flashing of P1.0 led, that is, press the P1.3 button and the P1.0 led will flash. I use g2553. The following is my own code, which is ...
junggle Microcontroller MCU
How to change the system's default sound output device?
I have two sound cards under my CE. After the system starts up, device 1 is selected as waveout by default every time. How can I change it to device 2?...
031005 Embedded System
I heard that the two rails on the railway are used to send signals. Is this true?
I would like to ask you a question. I heard that the two rails on the railway are used to send signals. Is this true?...
chilezhima Analog electronics
Filter Principles and Applications in Electronic Design
[b]Filter function[/b] 1. Separate useful signals from noise. 2. Suppress frequency components that are not of interest and improve the accuracy of signal analysis. [b]Filter classification[/b] Accord...
qwqwqw2088 Analogue and Mixed Signal
About 430F5529DA output sine wave and AD acquisition
This time I want to use MSP430F5529 to output a sine wave. I can use the peripheral DA, but I don't know which chip to choose, nor how to write the program....
李雪莹 Microcontroller MCU
Where can I download Borland C++ 4.5 software? Thank you
Where can I download the Borland C++ 4.5 software? Thank you! If there is no download, what compilation environment should I use to learn ucos-2?...
automation Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 24  630  1281  38  2175  1  13  26  44  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号