Part Number

Search

177-740-2-69GP6J5-18BSG

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

177-740-2-69GP6J5-18BSG Overview

Cable Assembly, 26AWG,

177-740-2-69GP6J5-18BSG Parametric

Parameter NameAttribute value
Objectid7005066867
Reach Compliance Codeunknown
YTEOL8.75
Other featuresSTANDARD: MIL-DTL-83513, EMI SHIELDED
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D MALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.129 mm2
DIN complianceNO
IEC complianceNO
insulator materialCROSSLINKED ETHYLENE-TETRAFLUOROETHYLENE
length0.466 mm
MIL complianceYES
Number of conductors69
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.147 Ω
shieldYES
stay19X38
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
[Smart Wardrobe] Material Unboxing ESP32-S3-BOX
I have used Espressif's development board before, and I feel it is easy to use overall. It is very friendly to the development of audio and video, camera, wifi and Bluetooth functions. After comparing...
reayfei DigiKey Technology Zone
A ZVS soft switching implementation scheme for a Flyback converter with an auxiliary transformer
Abstract: A novel ZVS soft switching scheme for FLYBACK converter is proposed. A smaller auxiliary transformer is connected in series with the main transformer, and the ZVS soft switching condition of...
wzt Power technology
About register setting problem when RTL8019AS sends data packets
I would like to ask, when using rtl8019as to send a data packet, how do I set the value of the RBCR and TBCR registers? That is, how do I determine the size of the data packet being sent?...
林泉 MCU
A valve is used in the water supply of the product. The valve is opened when water is used and closed when water is not used. How to measure the force of the opening and closing valve?
The product uses a valve for water supply. It opens when water is used and closes when water is not used. There is no in-position switch in the valve controller. It can only rely on the sensor to meas...
一沙一世 stm32/stm8
UAF42 Universal Active Filter Software
Is there anyone who can use UAF42 software to design filter circuits?...
sw3926 Analogue and Mixed Signal
ADI event sample application for the first time!
ADI samples can be applied for 4 types at a time, but now it has been upgraded and it seems that 8 types can be applied for. After waiting for more than ten days for the first application, 4 types wer...
蓝雨夜 ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 367  909  210  1607  1017  8  19  5  33  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号