Embedded Power for
Business-Critical Continuity
DA16 Series
16 Watts
Total Power:
Input Voltage:
# of Outputs:
16 Watts
90-264 Vac
Single
Rev. 11.19.08
DA16 Series
1 of 3
DA16-AU
DA16-UK
DA16-EU
DA16-US
Electrical Specifications
Special Features
• Switching wallmount
power supply
• Available in multiple ac plug
configurations
• CE Mark EMC & LVD
• Universal AC input
• Fully regulated output
• Overload and short circuit
protection
• Thermal protection
• Designed to meet Blue Angel
standard
• European Code of Conduct
compliance
• Constant voltage
• High efficiency
• High MTBF
• Built in EMI filter
(CISPR 22 Class B)
• LED power good indicator
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
90-264 Vac (wide range)
47-63 Hz
40 A @ 230 Vac, cold start @ 25 ºC
0.18 A rms @ 120 VAC; 0.36 A @ 240 VAC
75% @ full load typical, @120 VAC
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B & EMC89/336/EEC
300
µ
A @ 50/60 Hz, 230 Vac input
Output
Voltage (Vo):
Voltage regulation:
Maximum Power (Po):
Hold-up time:
Overvoltage protection:
Overload protection:
Overtemperature
protection:
Output cable/connector
barrel polarity:
12.2 V
± 5% @ constant voltage mode
16 W
20 ms. typical at full load @ 115 Vac
Non-latching type
Output shortcircuit protection auto recover
Overload protected @ 150% above maximum rating
Auto recovery
DC cable with 2.5 mm x5.5mm barrel plug
DC plug center +v
DC plug outer -v
Safety
• UL
• CSA
• TUV
• NEMKO
• AS/NZS
• CB
• CE
60950 / 6500
60950
60950
60950
60950
Certificate and report
EMC & LVD
Embedded Power for
Business-Critical Continuity
Rev. 11.19.08
DA16 Series
of 3
Environmental Specifications
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
0 ° to +40 °C ambient
-40 °C to +85 °C
Designed to meet EN55024
Operating; non-condensing 5% to 95%
RH
Three orthogonal axes, sweep at 1 oct/
min. 5 min. dwell at four major
resonances 2G peak 8 Hz to 500 Hz,
operational
>550,000 hours at full load and 25 °C
ambient conditions
AC Plug Configuration
U.S. 2-prong
Europe 2-prong
United Kingdom 3-prong
Australia 2-prong
US
EU
UK
AU
MTBF demonstrated:
Ordering Information
Model
Number
DA16-120US
DA16-120EU
DA16-120UK
DA16-120AU
Maximum
Power
16 W
16 W
16 W
16 W
Output
Voltage
12.2 V
12.2 V
12.2 V
12.2 V
Minimum
Load
0.2 A
0.2 A
0.2 A
0.2 A
Maximum
Load
1.33 A
1.33 A
1.33 A
1.33 A
Peak Load
1
1.5 A
1.5 A
1.5 A
1.5 A
Regulation2
± 3%
± 3%
± 3%
± 3%
Ripple
P/P (PARD)3
120 mV
120 mV
120 mV
120 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 mHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum loads are required.
Mechanical Drawing
DA16XX-US
(2,000) 78.7
(53.0) 2.08
DA16XX-AU
(10.5) 0.41
)
(60) 2.36
(77.0) 3.03
(75.0) 2.95
( 29.8 ) 1.17
(16.0) 0.63
(13.8) 0.54
(12.7) 0.50
(7.0) 0.27
(1.50) 0.06
(12.7) 0.50
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
DA16-XXX-EU
(2,000) 78.7
(10.5) 0.41
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 11.19.08
DA16 Series
3 of 3
(53.0) 2.08
Europe (UK)
(60) 2.36
(77.0) 3.03
(75.0) 2.95
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
(19.5) 0.76
(3.9) 0.13
(10.5) 0.41"
( 29.8 ) 1.17
(0.25) 0.01
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
(18.0) 0.71
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
(18.7) 0.74
(17.4) 0.68
DA16-XXX-UK
(2,000) 78.7
(10.5) 0.41
(53.0) 2.08
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
(60) 2.36
(77.0) 3.03
(75.0) 2.95
(8.02) 0.32
(3.95) 0.15
(7.91) 0.31
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”
3. Warranty: 2 year
4. Weight: 0.325 lb. / 0.148 kg.
(22.73) 0.89
(29.8) 1.17
(7.0) 0.27
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
(4.03) 0.15"
17.7 0.70
(6.25) 0.25
(3.96) 0.15