30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U Crystal
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS
Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MHz
Please specify the frequency
in xx.xxxxMHz.
e.g. 14.3181MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
MHz -
-
-
-
-
Packaging
T: Tape & Reel
P: Foam
Value Added
I
Insulator Tab
V
Vinyl Sleeve
Trimmed leads
QXX
See Table 2
MJ
Metal jacket
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
NOTE:
** -10 to +60C only.
Freq. Tolerance
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 50 ppm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriate code numbers for
other trimmed lengths not listed.
(e.g. Q14 for 0.14 inch (3.55 mm))
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 03.22.12
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U Crystal
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS
Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Metal Jacket Formed Leads
For Option MJ
Dimensions: inch (mm)
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 03.22.12
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U Crystal
AB
REFLOW PROFILE:
Pb
RoHS
Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
TAPE & REEL:
T: 1,000 pcs/reel
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 03.22.12
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
I just started learning microcontrollers. This is my first time to make a simple temperature alarm based on the examples in the book. There was a problem when linking. The main program is as follows: ...
It is known that the total harmonic distortion and noise calculation formula is: THD+N [%] = (H+N) / (S+H+N) Some manufacturers give data in dB units, which poses a conversion problem. Many materials ...
[backcolor=yellow]This is my LCD1602 program. [b]May I ask how these two addresses came out? [/b][/backcolor] [b][size=4]#define LCD_COM (*((unsigned int *)0x601000))[/size][/b] [b][size=4]#define LCD...
[font=微软雅黑][size=1][color=#ffffff]Instruments and meters yunrun.com.cn/product/[/color][/size][/font] [font=微软雅黑][size=3][color=#000000]The reliability of DCS is very high, but it is still inevitable ...
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
The rectified DC voltage is then converted back to AC using power electronics such as insulated gate bipolar transistors.
The output voltage is switched on and off at a high frequency, control...[Details]
1 Introduction
Ultrasound refers to elastic vibration with a frequency higher than the audible frequency limit (i.e., in the frequency band above 20 kHz). The propagation process of this vib...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
Every time I go home and walk up the stairs, I am always scared. The corridor lights are often broken, and no one changes the bulbs, or they are not smart enough and need to be operated manually. E...[Details]
a. Keep the battery clean, wipe off the spilled electrolyte, contaminated dirt and dust in time; keep the poles and terminal clamps clean and in good contact, and apply vaseline or butter to preven...[Details]
The capacity of a battery depends on the amount of charge and discharge, in addition to some factors of the battery itself. Obviously, if the charge and discharge of the battery can be recorded all...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
The principles to be followed are as follows:
(1) In terms of component layout, related components should be placed as close as possible. For example, clock generators, crystal oscillat...[Details]
As a new type of centralized and decentralized elevator control system, serial communication has been widely used in China. Compared with the previous centralized and unified control system, each s...[Details]
Abstract: Based on the analysis of the characteristics of the IRIG-B (DC) code type, a design method for IRIG-B (DC) time code decoding is proposed. This method consists of a small number of periph...[Details]
Traditional synthesis techniques are increasingly unable to meet the needs of today's very large and complex FPGA designs implemented in 90nm and below process nodes. The problem is that traditio...[Details]
UDN2916LB is a two-phase stepper motor bipolar driver integrated circuit launched by SANKEN. It can drive dual-winding bipolar stepper motors and is particularly suitable for controlling dual-step ...[Details]
In some motion control systems with simple control or low cost requirements, stepper motors are often used as actuators. The biggest advantage of stepper motors in such applications is that they ca...[Details]