Solid-state Timer
H3JA
Economical, Compact, Plug-in Timer
• Time limit, ON-delay, operation with automatic resetting.
• DIN size (36 x 36 mm), fits standard 8-pin sockets.
• Wide choice of supply voltages:
24, 100 to 120, 200 to 240 VAC, 12, 24 VDC.
• Dual LED indication for power and output status.
• Large transparent setting knob.
• Setting error rating almost matches that of a 48 x 48 timer.
• Conforms to UL and CSA, and meets CE marking
requirements.
Ordering Information
Stock Note:
Shaded models are normally stocked.
Operation/resetting
system
Time-limit operation/
self-resetting
Time-limit contact
SPDT
Mounting method
Surface mounting, flush
mounting, and DIN track
mounting
Rated time
1 s, 3 s, 5 s, 10 s, 30 s, 60 s,
H3JA-8A
3 min, 5 min, 10 min, 30
min, 60 min, 3 hrs
1 s, 3 s, 5 s, 10 s, 30 s, 60 s,
H3JA-8C
3 min, 5 min, 10 min, 30
min, 60 min, 3 hrs
Model
DPDT
Note:
Specify the model number, supply voltage, and rated time when ordering.
Ex. H3JA-8A 100 to 120 VAC 1 s
Rated time
Supply voltage
Solid-state Timer
H3JA
1
■
Accessories (Order Separately)
Stock Note:
Shaded models are normally stocked.
Name/specifications
Flush mounting adapter
Mounting track
50 cm (l) x 7.3 mm (t)
1 m (l) x 7.3 mm (t)
1 m (l) x 16 mm (t)
End plate
Spacer
Track mounting/
Front connecting socket
Back connecting socket
Hold-down clip (see note 2)
8-pin
8-pin
8-pin, finger safe type
For PF085A Socket
Y92F-31
PFP-50N
PFP-100N
PFP-100N2
PFP-M
PFP-S
PF085A
P3G-08
P3G-08 with Y92A-48G (see note 1)
Y92H-6
Model
Note: 1.
Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket.
2.
Hold-down Clips are sold in sets of two.
Specifications
■
Time Ranges
Rated time
1s
3s
5s
10 s
30 s
60 s
0.1 to 1 s
0.3 to 3 s
0.5 to 5 s
1 to 10 s
3 to 30 s
6 to 60 s
Time range
3 min
5 min
10 min
30 min
60 min
3 hrs
Rated time
Time range
0.3 to 3 min
0.5 to 5 min
1 to 10 min
3 to 30 min
6 to 60 min
0.3 to 3 hrs
■
Ratings
Rated supply voltage
Operating voltage range
Power consumption
24, 100 to 120 or 200 to 240 VAC (50/60 Hz);
24 VDC; 12 VDC (only available on H3JA-8A model)
85% to 110% of rated supply voltage
H3JA-8A
100 to 120 VAC: Approx. 3 VA (1.3 W) at 120 VAC
200 to 240 VAC: Approx. 5 VA (1.5 W) at 240 VAC
24 VAC: Approx. 1.2 VA (0.9 W) at 24 VAC
24 VDC: Approx. 0.8 W at 24 VDC
H3JA-8C
100 to 120 VAC: Approx. 3 VA (1.1 W) at 120 VAC
200 to 240 VAC: Approx. 5 VA (1.3 W) at 240 VAC
24 VAC: Approx. 1.3 VA (1 W) at 24 VAC
24 VDC: Approx. 0.9 W at 24 VDC
H3JA-8A: 7 A at 250 VAC, resistive load
H3JA-8C: 5 A at 250 VAC, resistive load
Control outputs
2
Solid-state Timer
H3JA
■
Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
±2%
max.
±7%
max.
±2%
max.
±5%
max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between
contact-carrying and control circuit, and between contacts of different poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±1.5
kV (between power terminals) and
±1.5
kV (between output terminals), square-wave noise by
noise simulator (pulse width: 100 ns/1
µs,
1-ns rise)
Destruction: 8 kV
Malfunction: 6 kV
Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each.
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each.
Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Operating: –10°C to 55°C
Storage: –25°C to 65°C
Operating: 35% to 85%
H3JA-8A
Mechanical: 10,000,000 operations min.
Electrical: 60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h)
H3JA-8C
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h)
(EMI)
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS)
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
UL508, CSA C22.2 No. 14, conforms to EN61812-1
Light gray (Munsell 5Y7/1)
IP40 (panel surface)
H3JA-8A: Approx. 50 g
H3JA-8C: Approx. 60 g
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Approved standard
Case color
Degree of protection
Weight
Solid-state Timer
H3JA
3
Engineering Data
■
H3JA-8A
Switching operations (x 10
3
)
5,000
■
H3JA-8C
Switching operations (x 10
3
)
30 VDC
resistive load
1,000
500
30 VDC
inductive
load
L/R=7 ms
120 VAC
resistive load
100
50
120 VAC
inductive
load
cosφ=0.4
250 VAC
resistive load
φ
0
1
2
3
4
5
6
7
Load current (A)
Load current (A)
4
Solid-state Timer
H3JA
Operation
■
Timing Chart
H3JA-8A
Terminals
(2)-(7) (power)
Set time
Set time
100 ms min.
Rt
(6)-(8) (NO)
(5)-(8) (NC)
Time UP indicator
(Orange)
Power ON indicator
(Green)
100 ms min.
H3JA-8C
Terminals
(2)-(7) (power)
Set time
Rt
Set time
(1)-(3) (NO)
(6)-(8)
(1)-(4)
(5)-(8) (NC)
Time UP indicator
(Orange)
Power ON indicator
(Green)
Dimensions
Unit: mm (inch)
7
36 (1.42)
LED
4
60 (2.36)
14.2
0.7
36
(1.42)
30.5
32.8
(1.29)
Solid-state Timer
H3JA
5