Cree
®
P4 LED
Model # LP476TYL1-90G-01
Data Sheet
90-degree, 7.6 x 7.6 mm LED lamp in amber color with water-transparent lens and stopper
Applications
•
•
•
Advertising Signs
Indicators
Automotive Lighting
Absolute Maximum Ratings (T
A
= 25°C)
Items
Forward Current
Note 2
Symbol
I
F
Note 1
Absolute Maximum Rating
70
200
5
220
-40 ~ +100
-40 ~ +100
Unit
mA
mA
V
mW
°C
°C
Peak Forward Current
Reverse Voltage
Power Dissipation
I
FP
V
R
P
D
T
opr
T
stg
T
sol
Operation Temperature
Storage Temperature
Lead Soldering Temperature
Max. 260°C for 3 sec. max.
(3 mm from the base of the epoxy bulb)
Notes:
1.
2.
Pulse width ≤0.1 msec, duty ≤1/10.
A heat sink is recommended if the device is operated at ambient temperatures higher than 25°C.
Typical Electrical & Optical Characteristics (T
A
= 25°C)
Characteristics
Forward Voltage
Reverse Current
Dominant Wavelength
Luminous Intensity
Symbol
V
F
I
R
λ
D
I
V
2θ½H-H
2θ½V-V
Condition
I
F
= 70 mA
V
R
= 5 V
I
F
= 70 mA
I
F
= 70 mA
I
F
= 70 mA
I
F
= 70 mA
Unit
V
μA
nm
mcd
deg
deg
584
1100
591
2500
90
35
Minimum
Typical
2.6
Maximum
3.2
100
599
LD-CT138.000
Data Sheet: C
50% Power Angle
Subject to change without notice.
www.cree.com/ledlamps
1
Standard Bins for LP476TYL1-90G-01 (I
F
= 70 mA)
Lamps are sorted to luminous intensity (I
V
), V
F
and dominant wavelength (λ
D
) bins shown.
Orders for LP476TYL1-90G-01 may be filled with any or all bins contained as below.
All luminous intensity (I
V
), V
F
and dominant wavelength (λ
D
) values shown and specified are at I
F
= 70 mA.
X2
X3
X4
X5
X6
X or
above
Luminous Intensity (I
V
)
4180 mcd
W
3000 mcd
V
2130 mcd
U
1520 mcd
T
1100 mcd
584 nm
587 nm
590 nm
593 nm
596 nm
599 nm
Dominant Wavelength (λ
D
)
Forward Voltage (V
F
)
Rank
Voltage
V4
2.2-2.4 V
V5
2.4-2.6 V
V6
2.6-2.8 V
V7
2.8-3.0 V
V8
3.0-3.2 V
Important Notes:
1. All ranks will be included per delivery; rank ratio will be based on the dice distribution.
2. Tolerance of measurement of luminous intensity is ±15%.
3. Tolerance of measurement of dominant wavelength is ±1 nm.
4. Tolerance of measurement of V
F
is ±0.05 V.
5. Packaging methods are available for selection; please refer to the “Cree LED Lamp Packaging Standard” docu-
ment.
6. Please refer to the “Cree LED Lamp Reliability Test Standards” document for reliability test conditions.
7.
Please refer to the “Cree LED Lamp Soldering & Handling” document for information about how to use this LED
product safely.
Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the
Cree logo are registered trademarks of Cree, Inc.
2
CLD-CT138.000
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
Fax: +1.919.313.5778
www.cree.com/ledlamps
Document No. SPE/LP476TYL1-90G-01
Rev. No.
02
Graphs
Graphs
-60
Vr(V)
-50
-40
-30
-20
-10
0.0
-10.0
-20.0
-30.0
-40.0
Vf(V)
100.0
80.0
60.0
40.0
20.0
If (mA)
0.0
2.0
2.2 2.4
2.6 2.8 3.0
FIG.1 FORWARD CURRENT VS.
FORWARD VOLTAGE.
Ir(uA)
FIG.2 REVERSE CURRENT VS.
REVERSE VOLTAGE.
-50.0
Half Power
WL=20nm
Domi WL= 591nm
2.5
2.0
1.5
1.0
0.5
0.0
0.0
If(mA)
20.0 40.0 60.0 80.0 100.0
I (RELATIVE LUMINOUS INTENSITY)
100%
75%
50%
25%
0%
400
WL(nm)
900
500
600
700
800
FIG.3 RELATIVE LUMINOUS INTENSITY VS.
FORWARD CURRENT.
FIG.4 RELATIVE LUMINOUS INTENSITY VS.
WAVELENGTH.
H-H : 90
V-V : 35
Ie(%)
100%
50% Power Angle :
100
80
60
40
20
0
Ta( C)
0
20
40
60
80
100
120
-90
-60
-30
0
30
IF(mA)
H-H
V-V
0
80%
60%
40%
20%
60
90
0%
FIG.5 MAXIMUM FORWARD DC CURRENT VS
AMBIENT TEMPERATURE (Tjmax=120 C)
FIG.6 FAR FIELD PATTERN
Items
Prepared by
Checked by
Approved by
FCN#
Signatures
LiuZM
Aldosin
David
Date
2005-05-18
2005-05-18
2005-05-18
Rev. No
02
Date
Revision History
Change Description
2005-05-18
Release. Change I
V
from U,V,W,X(typ)3000
to T,U,V,W(typ)2500mcd.
FCN20050163
Data is subject to change without prior notice; please refer to COTCO Website for the latest version.
Copyright@2002
Cotco International Ltd.
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
Fax: +1.919.313.5778
www.cree.com/ledlamps
4/4
Format #: COTCO-D-074
Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the
Cree logo are registered trademarks of Cree, Inc.
REV.4
3
CLD-CT138.000
Mechanical Dimensions
Document No. SPE/LP476TYL1-90G-01
All dimensions are in mm. Tolerance is ±0.25 mm unless otherwise noted.
Rev. No.
02
An epoxy meniscus may extend about 1.5 mm down the leads.
Dimensi
0.5
Dr
max.
Burr around bottom of epoxy may be
on
mm
aw ing
e maximum
ating
Unit
mA
mA
V
mW
70
200
5
220
~ +100
°C
°C
~ +100
Notes
0
°C
for 5 sec Max.
he base
RoHS Compliance
of the epoxy bulb)
The levels of environmentally sensitive, persistent biologically toxic (PBT), persistent organic pollutants (POP), or
otherwise restricted
at ambient temperatures higher than 25
concentration values (also
the device is operated
materials in this product are below the maximum
deg C. For long term
referred to as the
threshold limits) permitted for such substances, or are used in an exempted application, in accordance with EU Direc-
tive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment
A and 50mA are recommended. Please contact COTCO sales representative for more
(RoHS), as amended through April 21, 2006.
Vision Advisory Claim
.
Users
cs ( Ta = 2
should be cautioned not to stare at the light of this LED product. The bright light can damage the eye.
5
°C
)
Condition
Cree logo
I
F
= 70mA
Min.
---
Typ.
2.6
Max.
3.2
Unit
V
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
Fax: +1.919.313.5778
www.cree.com/ledlamps
Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the
are registered trademarks of Cree, Inc.
4
CLD-CT138.000
Kit Number System
Cree LED lamps are tested and sorted into performance bins. A bin is specified by ranges of color, forward voltage,
and brightness. Sorted LEDs are packaged for shipping in various convenient options. Please refer to the “Cree LED
Lamp Packaging Standard” document for more information about shipping and packaging options.
Cree LEDs are sold by order codes in combinations of bins called kits. Order codes are configured in the following
manner:
Standard/Custom
0: Standard
C: Custom
V
F
0: Full forward voltage distribution
1~9, A~Z . . . : special request *
Wd/Color
aaaaaaaaa-aaa-aa- x x x x x
I
V
1: Full-color distribution
2~9, A~Z . . . : special request *
0: Full luminous intensity distribution
1~9, A~Z . . . : special request *
Packing type
Product P/N
0: Standard = tube pack
1~9, A~Z . . . : special request *
* Contact your Cree sales representative for ordering information.
Standard Available Kits*
Kit Number
LP476TYL1-90G-01-00001
LP476TYL1-90G-01-00011
Description
P4 90 Amber 591nm, FULL RANK, Tube Pack
P4 90 Amber 591nm, U or above, Tube Pack
* Please contact your Cree representative about the availability of non-standard kits.
Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the
Cree logo are registered trademarks of Cree, Inc.
5
CLD-CT138.000
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
Fax: +1.919.313.5778
www.cree.com/ledlamps