ICs for Communications
DUAL CHANNEL SLICOFI-2, SLIC
DuSLIC
PEB
PEB
PEB
PEB
PEB
3264/-2 Version 1.1
4264/-2 Version 1.1
3265 Version 1.1
4265/-2 Version 1.1
4266 Version 1.1
Preliminary Data Sheet 10.99
DS 1
•
DuSLIC
Revision History:
Previous Version:
Page
Page
(in previous (in current
Version)
Version)
Subjects (major changes since last revision)
Current Version: 10.99
For questions on technology, delivery and prices please contact the Infineon Technologies Offices
in Germany or the Infineon Technologies Companies and Representatives worldwide:
see our webpage at http://www.infineon.com
November 8, 1999
•
ABM
®
, AOP
®
, ARCOFI
®
, ARCOFI
®
-BA, ARCOFI
®
-SP, DigiTape
®
, EPIC
®
-1, EPIC
®
-S, ELIC
®
, FALC
®
54, FALC
®
56,
FALC
®
-E1, FALC
®
-LH, IDEC
®
, IOM
®
, IOM
®
-1, IOM
®
-2, IPAT
®
-2, ISAC
®
-P, ISAC
®
-S, ISAC
®
-S TE, ISAC
®
-P TE,
ITAC
®
, IWE
®
, MUSAC
®
-A, OCTAT
®
-P, QUAT
®
-S, SICAT
®
, SICOFI
®
, SICOFI
®
-2, SICOFI
®
-4, SICOFI
®
-4µC,
SLICOFI
®
are registered trademarks of Infineon Technologies AG.
ACE
™
, ASM
™
, ASP
™
, POTSWIRE
™
, QuadFALC
™
, SCOUT
™
are trademarks of Infineon Technologies AG.
Edition 10.99
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81541 München
©
Infineon Technologies AG1999.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as warranted char-
acteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Infineon Technologiesis an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest Infi-
neon Technologies Office in Germany or our Infineon Technologies Representatives worldwide (see address list).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.
DuSLIC
Table of Contents
1
1.1
1.2
1.3
2
2.1
2.2
3
3.1
3.2
3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.4
3.4.1
3.4.2
3.4.3
3.5
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.6
3.7
3.7.1
3.7.2
3.7.2.1
3.8
3.8.1
3.8.2
3.8.3
3.8.4
Page
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Logic Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Pin Descriptions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Pin Diagram SLIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Pin Diagram SLICOFI-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Functional Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
DC Feeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
DC Characteristic Feeding Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Constant Current Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Resistive Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Constant Voltage Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Programmable Voltage and Current Range of DC Characteristic . . . . 3-14
SLIC Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Programmable Voltage Reserve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Extended Battery Feeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
AC Transmission Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
Transmit Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Receive Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Impedance Matching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
Ringing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Ringer Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Ring Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Ringing Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
DuSLIC Ringing Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
Internal Balanced Ringing via SLICs . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
Internal Unbalanced Ringing with SLIC-P . . . . . . . . . . . . . . . . . . . . . . 3-26
External Unbalanced Ringing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
Signaling (Supervision) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
Metering by 12/16 kHz Sinusoidal Bursts . . . . . . . . . . . . . . . . . . . . . . 3-29
Metering by Polarity Reversal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
Soft Reversal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
DuSLIC Enhanced Signal Processing Capabilities . . . . . . . . . . . . . . . . . 3-31
DTMF Generation and Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32
Caller ID Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
Line Echo Cancelling (LEC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
Universal Tone Detection (UTD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38
I
10.99
Preliminary Data Sheet
DuSLIC
Table of Contents
3.9
3.10
3.10.1
3.11
4
4.1
4.2
4.3
4.4
4.5
4.5.1
4.5.2
4.6
4.7
4.7.1
4.7.2
4.7.3
4.7.3.1
4.7.3.2
4.7.3.3
4.7.3.4
4.7.3.5
4.8
4.8.1
4.8.2
4.8.3
4.8.3.1
4.9
5
5.1
5.1.1
5.1.2
5.1.3
5.2
5.2.1
5.2.2
5.3
5.3.1
5.3.2
5.3.3
Page
Message Waiting Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
Three-party Conferencing (only DuSLIC-E/-E2/-P) . . . . . . . . . . . . . . . . . 3-42
Conferencing Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
16 kHz Mode on PCM Highway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44
Operational Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Operating Modes for the DuSLIC Chipset . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Operating Modes for DuSLIC-S and DuSLIC-S2 . . . . . . . . . . . . . . . . . . . . 4-5
Operating Mode for DuSLIC-E and DuSLIC-E2 . . . . . . . . . . . . . . . . . . . . 4-7
Operating Modes for DuSLIC-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Reset Mode and Reset Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Hardware and Power On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Software Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Interrupt Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Operating Modes and Power Management . . . . . . . . . . . . . . . . . . . . . . . 4-15
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Power Dissipation of the SLICOFI-2 . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Power Dissipation of the SLIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Power Down Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Active Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
SLIC Power Consumption Calculation in Active Mode . . . . . . . . . . 4-18
Ringing Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23
SLIC Power Consumption Calculation in Ringing Mode . . . . . . . . . 4-25
Test Modes (only for DuSLIC-E/-E2/-P) . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29
Conventional Line Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
DuSLIC Line Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30
Principles of Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
Test Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-38
Interfaces
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
PCM Interface with a Serial Microcontroller Interface . . . . . . . . . . . . . . . . 5-1
PCM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Control of the Active PCM Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Serial Microcontroller Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
The IOM-2 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
IOM-2 Interface Monitor Transfer Protocol . . . . . . . . . . . . . . . . . . . . . 5-12
SLICOFI-2 Identification Command (only IOM-2 Interface) . . . . . . . . . 5-16
TIP/RING Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
SLICOFI-2 and SLIC-S Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
SLICOFI-2 and SLIC-E Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20
SLICOFI-2 and SLIC-P Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22
Preliminary Data Sheet
II
10.99
DuSLIC
Table of Contents
6
6.1
6.2
6.2.1
6.2.1.1
6.2.1.2
6.2.2
6.2.3
6.2.4
6.2.4.1
6.2.4.2
6.3
6.3.1
6.3.1.1
6.3.1.2
6.3.2
6.3.3
6.3.3.1
6.3.4
6.3.5
6.3.6
6.3.6.1
6.3.6.2
7
7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
7.2
7.2.1
7.2.2
7.2.3
7.2.4
7.2.5
7.3
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
Page
SLICOFI-2x Command Structure and Programming
. . . . . . . . . . . . . . 6-1
Overview of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
SLICOFI-2S/-2S2 Command Structure and Programming . . . . . . . . . . . . 6-5
SOP-Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
SOP-Command Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
SOP-Command Register Description . . . . . . . . . . . . . . . . . . . . . . . 6-10
COP Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46
IOM-2 Interface Command/Indication Byte . . . . . . . . . . . . . . . . . . . . . 6-48
Programming Examples of the SLICOFI-2S/-2S2 . . . . . . . . . . . . . . . . 6-50
Microcontroller Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-50
IOM-2 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-51
SLICOFI-2 Command Structure and Programming . . . . . . . . . . . . . . . . . 6-53
SOP Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-53
SOP Command Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . 6-53
SOP Command Register Description . . . . . . . . . . . . . . . . . . . . . . . 6-58
COP Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-110
POP Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-112
POP Command Register Overview . . . . . . . . . . . . . . . . . . . . . . . . 6-112
POP Command Register Description . . . . . . . . . . . . . . . . . . . . . . . . 6-116
IOM-2 Interface Command/Indication Byte . . . . . . . . . . . . . . . . . . . . 6-145
Programming Examples of the SLICOFI-2 . . . . . . . . . . . . . . . . . . . . 6-147
Microcontroller Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-147
IOM-2 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-148
Electrical Characteristics
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Electrical Characteristics PEB 4264 (SLIC-S, SLIC-S2) . . . . . . . . . . . . . . 7-1
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Operating Range PEB 4264 (SLIC-S, SLIC-S2) . . . . . . . . . . . . . . . . . . 7-2
Thermal Resistances PEB 4264 (SLIC-S, SLIC-S2) . . . . . . . . . . . . . . . 7-2
Electrical Parameters PEB 4264 (SLIC-S, SLIC-S2) . . . . . . . . . . . . . . . 7-3
Power Calculation PEB 4264 (SLIC-S, SLIC-S2) . . . . . . . . . . . . . . . . . 7-5
Electrical Characteristics PEB 4265/-2 (SLIC-E/-E2) . . . . . . . . . . . . . . . . 7-7
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
Operating Range PEB 4265/-2 (SLIC-E/-E2) . . . . . . . . . . . . . . . . . . . . 7-8
Thermal Resistances PEB 4265/-2 (SLIC-E/-E2) . . . . . . . . . . . . . . . . . 7-8
Electrical Parameters PEB 4265/-2 (SLIC-E/-E2) . . . . . . . . . . . . . . . . . 7-9
Power Calculation PEB 4265/-2 (SLIC-E/-E2) . . . . . . . . . . . . . . . . . . . 7-11
Electrical Characteristics PEB 4266 (SLIC-P) . . . . . . . . . . . . . . . . . . . . . 7-13
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13
Operating Range PEB 4266 (SLIC-P) . . . . . . . . . . . . . . . . . . . . . . . . . 7-14
Thermal Resistances PEB 4266 (SLIC-P) . . . . . . . . . . . . . . . . . . . . . . 7-14
Electrical Parameters PEB 4266 (SLIC-P) . . . . . . . . . . . . . . . . . . . . . 7-15
Power Calculation PEB 4266 (SLIC-P) . . . . . . . . . . . . . . . . . . . . . . . . 7-19
III
10.99
Preliminary Data Sheet