POR Specifications....................................................................................................................................................81
AS Configuration Timing............................................................................................................................................86
DCLK Frequency Specification in the AS Configuration Scheme....................................................................................... 87
Minimum Configuration Time Estimation......................................................................................................................91
Remote System Upgrades......................................................................................................................................... 93
User Watchdog Internal Circuitry Timing Specifications..................................................................................................93
Document Revision History for the Intel Arria 10 Device Datasheet.......................................................................................... 99
Intel
®
Arria
®
10 Device Datasheet
2
Send Feedback
A10-DATASHEET | 2019.06.24
Send Feedback
Intel
®
Arria
®
10 Device Datasheet
This datasheet describes the electrical characteristics, switching characteristics, configuration specifications, and I/O timing
for Intel
®
Arria
®
10 devices.
Intel Arria 10 devices are offered in extended and industrial grades. Extended devices are offered in –E1 (fastest), –E2, and –
E3 speed grades. Industrial grade devices are offered in the –I1, –I2, and –I3 speed grades.
The suffix after the speed grade denotes the power options offered in Intel Arria 10 devices.
•
•
•
•
L—enables the device to operate at low static power while maintaining excellent performance.
S—standard power specification.
V—enables the device to run at lower than default V
CC
, reducing static and dynamic power while retaining equivalent
performance.
H—small device with high performance at the fastest speed grade (–1).
Related Information
Intel Arria 10 Device Overview
Provides more information about the densities and packages of devices in the Intel Arria 10 family.
Electrical Characteristics
The following sections describe the operating conditions and power consumption of Intel Arria 10 devices.
Operating Conditions
Intel Arria 10 devices are rated according to a set of defined parameters. To maintain the highest possible performance and
reliability of the Intel Arria 10 devices, you must consider the operating requirements described in this section.
Intel Corporation. All rights reserved. Agilex, Altera, Arria, Cyclone, Enpirion, Intel, the Intel logo, MAX, Nios, Quartus and Stratix words and logos are trademarks
of Intel Corporation or its subsidiaries in the U.S. and/or other countries. Intel warrants performance of its FPGA and semiconductor products to current
specifications in accordance with Intel's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Intel
assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in
writing by Intel. Intel customers are advised to obtain the latest version of device specifications before relying on any published information and before placing
orders for products or services.
*Other names and brands may be claimed as the property of others.
ISO
9001:2015
Registered
Intel
®
Arria
®
10 Device Datasheet
A10-DATASHEET | 2019.06.24
Absolute Maximum Ratings
This section defines the maximum operating conditions for Intel Arria 10 devices. The values are based on experiments
conducted with the devices and theoretical modeling of breakdown and damage mechanisms. The functional operation of the
device is not implied for these conditions.
Caution:
Table 1.
Conditions outside the range listed in the following table may cause permanent damage to the device. Additionally, device
operation at the absolute maximum ratings for extended periods of time may have adverse effects on the device.
Absolute Maximum Ratings for Intel Arria 10 Devices
Symbol
V
CC
V
CCP
V
CCERAM
V
CCPT
V
CCBAT
V
CCPGM
V
CCIO
Core voltage power supply
Periphery circuitry and transceiver fabric interface power supply
Embedded memory power supply
Power supply for programmable power technology and I/O pre-driver
Battery back-up power supply for design security volatile key register
Configuration pins power supply
I/O buffers power supply
Description
Condition
—
—
—
—
—
(1)
Minimum
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
–0.50
Maximum
1.21
1.21
1.36
2.46
2.46
2.46
4.10
2.46
2.46
1.34
1.34
2.46
1.27
4.10
2.46
2.46
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
continued...
3 V I/O
LVDS I/O
V
CCA_PLL
V
CCT_GXB
V
CCR_GXB
V
CCH_GXB
V
CCL_HPS
V
CCIO_HPS
Phase-locked loop (PLL) analog power supply
Transmitter power supply
Receiver power supply
Transceiver output buffer power supply
HPS core voltage and periphery circuitry power supply
HPS I/O buffers power supply
—
—
—
—
—
3 V I/O
LVDS I/O
V
CCIOREF_HPS
HPS I/O pre-driver power supply
—
(1)
The LVDS I/O values are applicable to all dedicated and dual-function configuration I/Os.
Intel
®
Arria
®
10 Device Datasheet
4
Send Feedback
Intel
®
Arria
®
10 Device Datasheet
A10-DATASHEET | 2019.06.24
Symbol
V
CCPLL_HPS
I
OUT
T
J
T
STG
HPS PLL power supply
DC output current per pin
Description
Condition
—
—
—
—
Minimum
–0.50
–25
(2)(3)(4)(5)
(6)
Maximum
2.46
25
125
150
Unit
V
mA
°C
°C
Operating junction temperature
Storage temperature (no bias)
–55
–65
Related Information
•
•
AN 692: Power Sequencing Considerations for Intel Cyclone 10 GX, Intel Arria 10, and Intel Stratix 10 Devices
Provides the power sequencing requirements for Intel Arria 10 devices.
Power-Up and Power-Down Sequences, Power Management in Intel Arria 10 Devices chapter
Provides the power sequencing requirements for Intel Arria 10 devices.
Maximum Allowed Overshoot and Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in the following table and undershoot to –2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
The maximum allowed overshoot duration is specified as a percentage of high time over the lifetime of the device. A DC signal
is equivalent to 100% duty cycle.
For example, a signal that overshoots to 2.70 V for LVDS I/O can only be at 2.70 V for ~4% over the lifetime of the device.
(2)
The maximum current allowed through any LVDS I/O bank pin when the device is not turned on or during power-up/power-down
conditions is 10 mA.
Total current per LVDS I/O bank must not exceed 100 mA.
Voltage level must not exceed 1.89 V.
Applies to all I/O standards and settings supported by LVDS I/O banks, including single-ended and differential I/Os.
Applies only to LVDS I/O banks. 3 V I/O banks are not covered under this specification and must be implemented as per the power
sequencing requirement. For more details, refer to
AN 692: Power Sequencing Considerations for Intel Cyclone
®
10 GX, Intel Arria
10, and Intel Stratix
®
10 Devices
and
Power Management in Intel Arria 10 Devices chapter.
For example, the commercial housing sold in the community was not equipped with an electricity meter. Later, they had to pay for the installation of the electricity meter. I paid the electrician more ...
Now I have a very difficult problem (for me). I originally had a USB hardware (industrial camera) and its driver, and a software (VC++ image processing) that can be developed to connect and use with t...
Node, gateway & cloud. [b]Nodes,[/b] devices used to collect information or control things, typically include processors, sensors, connectivity, power management and some analog signal chain. The sele...
Now configure the power-on sequence of the NCN6001 chip as follows: WrSPICmdOne(0xa5); WrSPICmdOne(0x83); DelayMS(1); WrSPICmdOne(0x87); DelayMS(6); WrSPICmdOne(0x97); After this configuration, the IC...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
VP2188 is a color STN LCD module produced by Jingdian Pengyuan. This module is a dot matrix transmissive color STN display screen with a color scale of 65 k colors and white LED backlight. Its core...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
OC faults may be the most frequent and the most frequent of all faults in the inverter. They alarm during the startup process, during the shutdown process, during operation, and even when powered o...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
In today's body control module (BCM) designs, savvy engineers are moving away from electromechanical relays whenever possible. Their next step is to eliminate fuses. But is eliminating fuses a nece...[Details]