EEWORLDEEWORLDEEWORLD

Part Number

Search

C0805T569M1GBC7867

Description
Ceramic Capacitor, Ceramic, 100V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.0000056uF, 0805,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C0805T569M1GBC7867 Overview

Ceramic Capacitor, Ceramic, 100V, 20% +Tol, 20% -Tol, C0G, -/+30ppm/Cel TC, 0.0000056uF, 0805,

C0805T569M1GBC7867 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711130681
package instruction, 0805
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance0.0000056 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee3
length2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Paper, 7 Inch
positive tolerance20%
Rated (DC) voltage (URdc)100 V
seriesC(SIZE)-COTS
size code0805
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.2 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
Core capacitor
Excuse me, can anyone explain the knowledge about through-core capacitors? Thank you!!!...
jaoiswen Discrete Device
DSP/BIOS boot sequence
[size=4]When the DSP/BIOS application starts, it generally follows the following steps: [/size] [size=4] [/size] [size=4]1) Initialize DSP: The DSP/BIOS program starts running from the C/C++ environme...
Jacktang Microcontroller MCU
請問關於 /etc/init.d/rcS 啟動程式 (AM335X SK)
請問前輩我使用AM335X SK (使用SD卡開機) file system = arago-base-tisdk-image-am335x-evm.tar.gz我編譯好一個xxxAP ,放置SD卡 rootfs /test 下 修改 rootfs /etc/init.d/rcS 最後一行 為 ./test/xxxAP 但AM335X Starter Kit SD卡開機不會執行xxxAP若我登入後...
justin0710 DSP and ARM Processors
Fundamentals of Analog Electronics Technology
Fundamentals of Analog Electronics Technology...
dhr869377235 Analog electronics
STC12C5A60S2 power supply problem
I used STC12C5A60S2 to make something. After I downloaded it with the USB downloader made by Du Yang, the external power supply did not work. It could only be powered by the USB downloader and in addi...
王阿东 51mcu
How to connect PCB digital ground and analog ground
[i=s] This post was last edited by Firefly on 2017-8-3 20:26 [/i] Dear teachers, the following pictures are the PCB drawings of the DA converter according to the ADI manual. The first picture is the a...
萤火 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 214  2670  1187  2916  1298  5  54  24  59  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号