EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-C21A-U3M2-DB1A1B-15A

Description
cir brkr mag-hydr 15a 80vdc
CategoryCircuit protection    Circuit protection   
File Size215KB,7 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

8345-C21A-U3M2-DB1A1B-15A Overview

cir brkr mag-hydr 15a 80vdc

8345-C21A-U3M2-DB1A1B-15A Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Reach Compliance Codecompliant
Actuator typeTOGGLE
Other featuresINTERRUPTING CURRENT-MAX(DC): 10000 A
Fusing characteristicsMEDIUM
body width19.1 mm
body height48 mm
Body length or diameter63.5 mm
circuit functionTRIP FREE
Circuit protection typeMAGNETIC CIRCUIT BREAKER
Environmental characteristicsCORROSSION RESISTANT; IP40; IP00
Installation featuresPANEL MOUNT
Number of poles1
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
physical size63.5mm x 19.1mm x 48mm
Rated breaking capacity5000 A
Rated current15 A
Rated voltage (AC)240 V
Rated voltage (DC)80 V
GuidelineCBE; CCC; EN; UL; VDE
surface mountNO
Terminal shapeSTUD
Base Number Matches1
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
8345
1-pole
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
K1, M1, T1,
K2, M2, T2
452
376
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
Technical data
Voltage rating
Current rating range
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V,
0.05...125 A single and multipole
150...180 A single pole, two poles
connected in parallel
higher ratings upon request
AC 240 V 6 A; DC 28 V 3 A
DC 65 V 1 A; DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ±0,76mm (10-57Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ±0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5% salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 90 - 120 g per pole
depending on version
3
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
pole to pole
main to auxiliary circuit
switching to trip circuit
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
Interrupting capacity
to EN 60934, UL 489 and UL 1077
IEC 60934 – test series E
voltage
number of poles
DC 80 V
1+2
AC 240/415 V
1-6
AC 240 V
1
UL 489 – test sequence Z
voltage
number of poles
DC 80 V
1+2
AC 120 V
1
AC 120/240 V
1
AC 240 V
1 (2)
UL 1077
voltage
number of poles
DC 80 V
1+2
AC 277/480 V
1-6
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
cn
(A)
10,000
6 x I
N
5,000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10,000
5,000
5,000
5,000
Approvals
VDE (EN 60934)
UL 489
UL 1077
CCC
1- to 6-pole
1- to 6-pole
1- to 4-pole
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10,000
5,000
06/07
(101106)
www.e-t-a.com
3
- 27
Modeling and simulation of power electronics and motor control systems
Modeling and simulation of power electronics and motor control systems...
Eways-SIC Motor Drive Control(Motor Control)
NMOS+PMOS controls battery voltage output
NMOS+PMOS controls the battery voltage output1. When MCU_CTL is high, Q5 and Q1 are turned on, and BAT_OUT outputs the battery voltage of 3.7V. This is no problem2. When MCU_CTL is low, Q5 and Q1 are ...
QWE4562009 Discrete Device
I saw a sentence on the Internet: Are you still together with the person you fell in love with when you were 17?
The Chinese Valentine's Day is coming soon, let's create an atmosphere, as the title says:)...
phantom7 Talking
Brushless DC Motor Control System Based on Stellaris M3
Brushless DC Motor Control System Based on Stellaris M3...
taburiss001 Microcontroller MCU
There are no debuggable cpus? How to solve it?
There are no debuggable cpus in the target configuration editor? How to solve it?...
376838498 Microcontroller MCU
What is the circuit diagram for implementing the sampling theorem on the signal and system test box? ? I used an electric pen to test it for several days...
The teacher asked me to use this thing, saying it is very useful, and to understand the principle. But we have just finished learning analog electronics, what is this 555, how to understand the princi...
gaoxin0531 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 587  261  1477  498  136  12  6  30  11  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号