EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F475-K4Q0-A2H0-50A

Description
cir brkr mag 50a 240vac 80vdc
CategoryCircuit protection   
File Size445KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8340-F475-K4Q0-A2H0-50A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F475-K4Q0-A2H0-50A - - View Buy Now

8340-F475-K4Q0-A2H0-50A Overview

cir brkr mag 50a 240vac 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
2-pole
Standard current ratings and typical internal resistance values
Current rating (A)
K1, M1, T1,
0.02
0.05
0.1
0.25
0.5
0.75
1
2
2.5
3
5
6
8
10
12
15
16
20
25
30
40
50
2669
452
100
15.5
3.9
1.65
0.95
0.26
0.15
0.10
0.042
0.029
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
M2, T2
2457
376
94
14.7
3.2
1.56
0.90
0.20
0.15
0.10
0.040
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A single pole (40+50 A DC only)
0.02...30 A multipole
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
4
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
4
- 13
TI's NFC reference design circuit diagram
...
dontium RF/Wirelessly
7.18 Week Highlights Review~~
:loveliness:Every week there are different highlights. Let's review what wonderful posts there were last week~~ [url=https://bbs.eeworld.com.cn/thread-495036-1-1.html]1-4 series smart battery fuel gau...
okhxyyo Talking
Ask a question about muxSend
1 First of all, I would like to ask, is the etherOutput function no longer supported in VXWORKS6.4? I did not find the definition of this function in etherLib. 2 I want to make a program that intercep...
fsaok Embedded System
Ask: Circuit Analysis
Can someone help me analyze the circuit: 1. Is Ui DC or AC? Why? 2. Why are the waveforms of Ur and UL as shown in the figure?...
icy Analog electronics
How to define the function type in the .h file
When programming with iar, void PIDInit (PID *pp) { memset(pp,0,sizeof(PID)); } will appear during runtime. Warning[Pe223]: function "memset" declared implicitly F:\msp430 program\pwm duty cycle\pwm.c...
刘123 MCU
2020 Share the beauty of Qingdao in my eyes
[i=s]This post was last edited by qditz on 2020-1-17 15:36[/i]In the most beautiful season, meet the most beautiful Qingdao. Every picture seems familiar, and every picture makes you and me linger. Lo...
qditz Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 472  751  2853  2722  55  10  16  58  55  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号