EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-C02A-U3M1-DB1B2B-100A

Description
cir brkr thrm 100a
CategoryCircuit protection   
File Size648KB,10 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-C02A-U3M1-DB1B2B-100A Online Shopping

Suppliers Part Number Price MOQ In stock  
8345-C02A-U3M1-DB1B2B-100A - - View Buy Now

8345-C02A-U3M1-DB1B2B-100A Overview

cir brkr thrm 100a

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current rating (A)
Trip curves and internal
resistance (Ω) per pole
K1, M1, T1
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
452
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
M2, T2
376
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
8345
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.05...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
upside down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
4
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1 - (6)
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1-6
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
UL 489 – test sequence Z:
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
4
- 25
[Special Topic] Three new trends in power management: a strong driving force for the diversification of portable product functions
Portable products such as PMP, mobile phones , PDAs, etc. are accelerating to become "personal entertainment and business centers". In order to support the endless new functions, manufacturers' demand...
zbz0529 Power technology
[Share] Application of using single chip control board instead of PLC
Single-chip industrial control board Single-chip control board 20-point control board: JMDM-20DIO control board manual Features: 1: 8-bit high-performance single-chip microcomputer as the main control...
jingmindm MCU
Misunderstandings in the Anti-interference Technology of Software in MCS51 Series Single-Chip Microcomputers
Abstract PIC microcontrollers are becoming increasingly popular in China. This article introduces some experience and skills in software and hardware design during the development of Microchip PIC ser...
rain 51mcu
m23 continuous data upload problem
I originally wanted to confirm whether a piece of data was uploaded successfully through mutual confirmation between the server and the module, but if many clients upload at the same time, it will cau...
lj107 Embedded System
What is the process of mass production of PCB boards?
I am still a student, and I usually send some boards to factories for processing and use for projects. I would like to ask: What steps do large companies like Apple and Huawei need to go through befor...
霖霖霖 PCB Design
Electronics Engineering~~~~ Help!
I will go to study in the UK next year. I have chosen the major of electronic engineering and now I have to write a personal statement, so I need to have an understanding of electronic engineering. Is...
qu27jump Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 327  2672  97  2373  366  7  54  2  48  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号