Ordering Information .................................................................................................................................................................... 2
Dimensions and Patterns ― 3.2 x 2.5 mm................................................................................................................................. 14
Dimensions and Patterns ― 5.0 x 3.2 mm................................................................................................................................. 14
Dimensions and Patterns ― 7.0 x 5.0 mm................................................................................................................................. 15
Additional Information ................................................................................................................................................................ 16
Revision History ......................................................................................................................................................................... 17
Rev 1.07
Page 3 of 17
www.sitime.com
SiT3372
1 MHz to 220 MHz Ultra-low Jitter Differential VCXO
Electrical Characteristics
Table 2. Electrical Characteristics – Common to LVPECL, LVDS and HCSL
All Min and Max limits in the Electrical Characteristics tables are specified over temperature and rated operating voltage with standard
output termination shown in the termination diagrams. Typical values are at 25°C and nominal supply voltage.
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
Min.
1
-15
-25
-35
-50
Operating Temperature Range
T_use
-20
-40
-40
-40
Supply Voltage
Vdd
2.97
2.7
2.52
2.25
Pull Range
PR
Typ.
–
–
–
–
–
–
–
–
–
3.3
3.0
2.8
2.5
Max.
220
+15
+25
+35
+50
+70
+85
+95
+105
3.63
3.3
3.08
2.75
Unit
MHz
ppm
ppm
ppm
ppm
°C
°C
°C
°C
V
V
V
V
ppm
See the APR (Absolute Pull Range)
Table 11.
Contact SiTime
for custom pull range options
Voltage at which maximum frequency deviation is guaranteed
Voltage at which minimum frequency deviation is guaranteed
Contact SiTime
for other input bandwidth options
Extended Industrial
Extended Commercial
Industrial
Condition
Accurate to 6 decimal places
Inclusive of initial tolerance, operating temperature, rated power
supply voltage, load variations, and first year aging at 25
°C,
with VIN voltage at Vdd/2.
±15
ppm is only guaranteed for pull range up to
±100
ppm.
Frequency Range
Frequency Stability
Temperature Range
Supply Voltage
Voltage Control Characteristics
±25, ±50, ±80, ±100, ±150,
±200, ±400, ±800, ±1600,
±3200
90%
–
–
–
–
–
–
10
10
–
–
10%
–
–
1.0
–
Input Characteristics
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Startup Time
OE Enable/Disable Time
VIH
VIL
Z_in
DC
T_start
T_oe
70%
–
–
45
–
–
–
–
100
–
–
–
–
30%
-
55
3.0
3.8
Vdd
Vdd
kΩ
%
ms
µs
Measured from the time Vdd reaches its rated minimum value
f = 156.25 MHz. Measured from the time OE pin reaches
rated VIH and VIL to the time clock pins reach 90% of swing
and high-Z. See
Figure 9
and
Figure 10
Pin 2, OE
Pin 2, OE
Pin 2, OE logic high or logic low
Upper Control Voltage
Lower Control Voltage
Control Voltage Input Impedance
Control Voltage Input Bandwidth
Pull Range Linearity
Frequency Change Polarity
VC_U
VC_L
VC_z
V_c
Lin
–
Vdd
Vdd
MΩ
kHz
%
Positive Slope
Output Characteristics
Startup and OE Timing
Rev 1.07
Page 4 of 17
www.sitime.com
SiT3372
1 MHz to 220 MHz Ultra-low Jitter Differential VCXO
Table 3. Electrical Characteristics – LVPECL Specific
Parameter
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Maximum Output Current
Output High Voltage
Output Low Voltage
Output Differential Voltage Swing
Rise/Fall Time
RMS Period Jitter
[4]
RMS Phase Jitter (random)
Symbol
Idd
I_OE
I_leak
I_driver
VOH
VOL
V_Swing
Tr, Tf
T_jitt
T_phj
Min.
–
–
–
–
Vdd-1.15
Vdd-2.0
1.2
–
–
–
Typ.
78
53
0.15
–
–
–
1.6
225
1.0
0.225
Max.
92
61
–
33
Vdd-0.7
Vdd-1.5
2.0
290
1.6
0.270
Unit
mA
mA
A
mA
V
V
V
ps
ps
ps
Condition
Excluding Load Termination Current, Vdd = 3.3 V or 2.5 V
OE = Low
OE = Low
Maximum average current drawn from OUT+ or OUT-
See
Figure 5
See
Figure 5
See
Figure 6
20% to 80%, see
Figure 6
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3 V or 2.5 V
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -20 to 70°C and -40 to 85°C
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -40 to 95°C and -40 to 105°C
f = 156.25 MHz, IEEE802.3-2005 10 GbE jitter mask integration
bandwidth = 1.875 MHz to 20 MHz, includes spurs, all Vdd
levels
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3 V or 2.5 V
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -20 to 70°C and -40 to 85°C
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -40 to 95°C and -40 to 105°C
f = 156.25 MHz, IEEE802.3-2005 10 GbE jitter mask integration
bandwidth = 1.875 MHz to 20 MHz, includes spurs, all
[align=center] [b][size=4]Let's learn MSP430F6638 together - Preface[/size][/b][/align] I participated in a competition some time ago and won a lab box awarded by TI. I never had the chance to learn i...
I want to make a signal generator and use FPGA to implement the DDS part. Now I am confused: For example, if I want to output a sine wave with a frequency of 100K, and my ROM stores 1024 points, then ...
Accompany you to learn FPGA----Sanxin Intelligent Hao Xushuai team : https://training.eeworld.com.cn/course/6024Accompany you to learn FPGA ---- Hao Xushuai team of Sanxin Intelligent...
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
In today's body control module (BCM) designs, savvy engineers are moving away from electromechanical relays whenever possible. Their next step is to eliminate fuses. But is eliminating fuses a nece...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
Abstract: In order to realize wireless automatic alarm and monitoring of major safety places, based on the basic principle of pyroelectric infrared sensing, a detector for receiving infrared radia...[Details]
1 What is an LED floodlight?
LED downlights are also called spotlights, projection lamps, and spotlights. They are mainly used for architectural decorative lighting and commercial space lighti...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
1 Load Regulation
Changes in power supply load will cause changes in power supply output. When the load increases, the output decreases, and vice versa, when the load decreases, the output inc...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
The automotive power electronics market has grown rapidly as comfort and active safety features become more common. As traditional mechanical functions shift to electronic applications, the demand ...[Details]
Applying fieldbus technology on new beer production lines is the first choice for large beer companies with strong management level and technical strength. Guangzhou Zhujiang Beer Group Co., Ltd. i...[Details]
Fairchild's FAN6208 is a synchronous rectification (SR) controller for isolated LLC or LC resonant converters that can drive two individual SR MOSFETs emulating the behavior of rectifier diodes. FAN62...[Details]
In some motion control systems with simple control or low cost requirements, stepper motors are often used as actuators. The biggest advantage of stepper motors in such applications is that they ca...[Details]
In recent years, the application of single-chip microcomputer systems in the field of industrial measurement and control has become more and more extensive. However, for industrial sites with harsh...[Details]