XTH706M060R4C/STN

Description
Tantalum Capacitor, Polarized, Tantalum (wet), 60V, 20% +Tol, 20% -Tol, 70uF, Chassis Mount
File Size152KB,11 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance  
Download Datasheet Parametric View All

XTH706M060R4C/STN Overview

Tantalum Capacitor, Polarized, Tantalum (wet), 60V, 20% +Tol, 20% -Tol, 70uF, Chassis Mount

XTH706M060R4C/STN Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2065169989
package instruction,
Reach Compliance Codeunknown
Country Of OriginUSA
ECCN codeEAR99
YTEOL.44
capacitance70 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (WET)
leakage current0.18 mA
Installation featuresCHASSIS MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature175 °C
Minimum operating temperature-55 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)60 V
ripple current375 mA
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeBINDING POST
XTH, XTK, XTL, XTM, XTV
www.vishay.com
Vishay
Wet Tantalum Capacitors
Cylindrical Body, Hermetically Sealed
FEATURES
• High temperature
• High voltage
• High capacitance
• Withstands high frequency vibration to 2000 Hz
• Hermetically sealed
• Long shelf life
• DLA drawings 04022 and 04033
• Terminations: standard 100 % nickel (RoHS compliant)
PERFORMANCE CHARACTERISTICS
Operating Temperature:
-55 °C to +175 °C with proper
derating
Voltage Range:
8 V
DC
to 630 V
DC
at 85 °C
Reverse Voltage:
none
Capacitance Range:
2 μF to 2200 μF
Tolerance Range:
-15 % to +50 % (standard for XTK, XTM, XTV)
-15 % to +75 % (standard for XTH, XTL)
± 20 % (special order)
• Mounting: arrays and assemblies
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
ORDERING INFORMATION
XTV
MODEL
XTH
XTK
XTL
XTM
XTV
126
CAPACITANCE
CODE
This is expressed
in picofarads.
The first two
digits are the
significant
figures. The
third is the
number of
zeros to follow.
T
CAPACITANCE
TOLERANCE
T = -15 % to +50 %
(XTK, XTM, XTV standard)
U = -15 % to +75 %
(XTH, XTL standard)
M = ± 20 %
(special order)
630
DC VOLTAGE
RATING
This is expressed
in volts. To
complete the
three-digit block,
zeros precede
the voltage rating.
P
CASE CODE
P = polar
(case negative)
R = reverse
polarity
(case positive)
0
INSULATION
0 = uninsulated
(standard)
4 = teflon
(+175 °C limit)
A
TERMINAL
CONFIGURATION
See Styles
Note
• For styles, terminal configurations, mounting methods and hardware, please see pages following Standard Ratings table
DIMENSIONS
in inches [millimeters]
XTH-XTL-XTV
H
(+)
D
Case
negative
5/16 ± 1/16
XTK-XTM
D
2.250
± 0.250
(+)
H
2.250
± 0.250
(-)
0.281
± 0.062
0.281
± 0.062
TYPE
XTK - XTM
XTL - XTH
XTV
D
0.656
0.875
1.125
H
0.438 to 1.781
0.540 to 4.062
0.600 to 2.810
Note
• For insulated parts, add 0.015" [0.38] to the diameter. The insulation shall lap over the ends of the capacitor body
Revision: 03-Apr-18
Document Number: 42077
1
For technical questions, contact:
tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
WEBENCH design exchange group, everyone is welcome to join!
[font=楷体, 楷体_GB2312][size=5]In order to let more netizens experience the simplicity of WEBENCH, a WEBENCH design exchange group is created! [color=#ff0000]Group number: 296935998[/color] [/size][/font...
maylove Analogue and Mixed Signal
Summary of scan test problems
1. Insufficient hold time causes data errors at the beginning of a register (PC audio) 2. Use JTAG scan to enter scan mode, but because both regulators are turned off when entering scan mode, and one ...
cscl Test/Measurement
AT89C51 MCU Performance Introduction
AT89C51 is a low-voltage, high-performance CMOS 8-bit microprocessor with 4K bytes of flash programmable and erasable read-only memory (FPEROM), commonly known as a single-chip microcomputer. The devi...
rain 51mcu
495 C language questions you must know
495 C language questions you must know...
tiankai001 MCU
EEWORLD University Hall----The cooling solution in TI's high power density power supply design
TI's Thermal Solution for High Power Density Power Design : https://training.eeworld.com.cn/course/3680...
wanglan123 Talking
[River Crab] There are also river crabs on technical websites
:funk: There are also censors on technical websites, and the moderators are also blockers!...
h0nly_zhang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2740  1807  1664  2604  13  56  37  34  53  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号