opening per section that accepts 350MCM - #6. 3 openings
total. This block has 6 load openings per section. Each
opening accepts #6 - #14 wire. A total of 18 openings are
on the 3-pole block.
Picture shown:
3-Pole - 1 opening on line per pole
6 opening on load per pole
Power Distribution Blocks (600V) Catalog Data
Catalog
Number
16021
16023
16220
16321
16323
16325
16327
16330
16332
16335
16370
16371
16372
16373
16375
16376
16377
16528
16530
16541
1-Pole
NA
NA
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
–1
2-Pole
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
3-Pole
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
–3
4-Pole
-4
-4
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Connection
Line
2/0 - #14Cu, 2/0 - #8Al
350MCM - #6Cu-Al
2/0 - #14Cu, 2/0 - #8Al
2/0 - #14Cu-Al
350MCM - #6Cu-Al
(2) 2/0 - #14Cu, 2/0 - #8Al
500MCM - #2Cu-Al
500MCM - #6Cu-Al
350MCM - #60Cu-Al
500MCM - #6Cu-Al
350MCM - #6Cu-Al
350MCM - #6Cu-Al
350MCM - #6Cu-Al
350MCM - #6Cu-Al
600MCM - #2Cu-Al
600MCM - #2Cu-Al
(2)300MCM - #2Cu-Al
(2) 600MCM - #2Cu-Al
(2) 500MCM - #6Cu-Al
500MCM - #6Cu-Al
Load
(6) #4 - #14Cu, #4 - #8Al
(6) #4 - #14Cu, #6 - #12Al
(4) #4 - #14Cu, #4 - #8Al
(6) #4 - #14Cu/#8Al
(6) #4 - #14Cu, #4 - #12Al
(6) #4 - #14Cu, #4 - #12Al
(6) #4 - #14Cu, #4 - #12Al
(6 )#2 - #14Cu/#8Al
(3) #2 - #14Cu/#8Al
(2) 1/0 - #14Cu/#8Al
(3) #2 - #14 Cu/#8Al
(2) 1/0 - #14Cu/#8Al
(12) #4 - #14Cu/#8Al
(6) #2 - #14Cu/#8Al
(3) 1/0 - #14Cu/#8Al
(21) #10 - #14Cu/#10Al
(3) 1/0 - #14Cu/#8Al
(14) #10 - #14Cu/#8Al
(12) #4 - #14Cu/#8Al
(6) #2 - #14Cu/#8Al
(3) 1/0 - #14Cu/#8Al
(12) #4 - #14Cu/#8Al
(4) 3/0 - #8Cu-Al
(4) #4 - #14Cu, #4 - #12Al
(12) #4 - #14Cu, #4 - #12Al
(21) #6 - #14Cu, #6 - #12Al
Connector
Material and
Ampacity
Al-175A
Al-310A
Al-175A
Al-175A
Al-310A
Al-350A
Al-380A
Al-380A
Al-310A
Al-380A
Al-310A
Al-310A
Al-310A
Al-310A
Al-420A
Al-420A
Al-570A
Al-840A
Al-760A
Al-380A
CSA
•
•
•
•
•
•
•
•
•
•
—
•
•
•
•
•
•
—
—
•
—
U.L.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
How To Order:
Catalog Number + # of Poles
Example:
16021-3 (complete part number)
12-28-98
SB98107
Rev. A
Form No. PDB
Page 1 of 3
BIF Doc #1117
Bussmann
®
Power Distribution & Terminal Blocks
Splicer Terminal Blocks
600 Volt AC or DC
Catalog Symbol:
Splicer Terminal Blocks
Voltage Rating:
600 Volts AC or DC maximum
Agency Approvals:
U.L. Recognized, Guide XCFR2, File E84923
CSA Certified, Class 6228-01, File 15364
Picture shown:
3-Pole - 1 opening on line per phase
1 opening on load per phase
PDB
Power Distribution Blocks (600V) Catalog Data
Catalog
Number
16000
16003
16005
16200
16201
16204
16301
16303
16500
16504
Connection
1-Pole 2-Pole 3-Pole 4-Pole Line
NA
NA
NA
-1
-1
-1
-1
-1
-1
-1
-2
-2
-2
-2
-2
-2
-2
-2
-2
-2
-3
-3
-3
-3
-3
-3
-3
-3
-3
-3
-4
-4
-4
NA
NA
NA
NA
NA
NA
NA
2/0 - #8Cu-Al
250MCM - #6Cu
350MCM - #6Cu-Al
#2 - #14Cu, #2 - #8Al
1/0 - #14Cu
2/0 - #8Cu-Al
250MCM - #6Cu
350MCM - #6Cu-Al
(2) 350MCM - #4Cu-Al
(2) 500MCM - #6Cu-Al
Load
2/0 - #8Cu-Al
250MCM - #6Cu
350MCM - #6Cu-Al
#2 - #14Cu, #2 - #8Al
1/0 - #14Cu
2/0 - #8Cu-Al
250MCM - #6Cu
350MCM - #6Cu-Al
(2) 350MCM - #4Cu-Al
(2) 500MCM - #6Cu-Al
Connector
Material and
Ampacity
Al-175A
Cu-255A
Al-310A
Al-115A
Cu-150A
Al-175A
Cu-255A
Al-310A
Al-620A
Al-760A
•
•
•
•
•
•
•
•
•
•
—
—
—
•
•
•
•
•
•
•
12-28-98
SB98107
Rev. A
Form No. PDB
Page 2 of 3
BIF Doc #1117
CSA
U.R.
Bussmann
®
Power Distribution & Terminal Blocks
Connector-Stud and Stud-Stud Blocks
600 Volt AC or DC
PDB
Catalog Symbol:
Connector–Stud Block
Voltage Rating:
600 Volts AC or DC maximum
Agency Approvals:
U.L. Recognized, Guide XCFR2, File E84923
CSA Certified, Class 6228-01, File 15364
Series 162, 163, 164, and 165 Dimensional Data
(Available 1, 2, and 3 pole)
H J
Series 160 (Available 2, 3, and 4 pole)
Dimensional Data
2.06"
LINE
SIDE
0.5"
0.69"
F
4.13" (2-Pole)
5.38" (3-Pole)
6.58" (4-Pole)
.25"
3.63"
4.88"
6.13"
A B
E
E
C
D
LINE
SIDE
0.41" C'Bore
G
2.8"
1" 2.0"
1.4"
LOAD
SIDE
.25"
0.27" Dia.
(2 Holes)
Slot 0.22" x 0.38".
(4 Places)
0.38"
0.20" Dia.
Dimensions for Series 162, 163, 164, and 165
LOAD
SIDE
Cat.
No.
162
163
165
A
2.88
4.0
5.5
B
2.25
3.38
4.75
C1
C2
C3
2.69
5.20
8.5
D
1.75
3.32
3.13
E
0.81
1.62
2.69
F
G
H
J
K
0.20
0.20
0.20
L
0.41
0.41
0.41
160 Series Bases have mounting holes outside the barriers. Other bases
(162 through 165) have mounting holes within barriers–see dimensional
drawings.
1.06 1.88
1.96 3.58
3.12 5.81
0.53 0.31 0.84 0.31
0.97 0.31 0.87 0.35
1.56 0.38 1.38 0.63
Connector-Stud Blocks (600V) Catalog Data
Catalog
Number
Connector – Stud
16280
16281
16378
16383
16582
Stud – Stud
16390
16394
16395
16591
16593
-1
-1
-1
-1
-1
-2
-2
-2
-2
-2
-3
-3
-3
-3
-3
‹Ω• - 16 ≈ 1⁄Ω•
Stud
⁄Ω™ - 13 ≈ 1⁄Ω¡§
Stud
‹Ω• - 16 ≈ 1‡Ω¡§
Stud
‹Ω• - 16 ≈ 1‡Ω¡§
Stud
⁄Ω™ - 13 ≈ 1
Stud
‹Ω• - 16 ≈ 1⁄Ω•
Stud
⁄Ω™ - 13 ≈ 1⁄Ω¡§
Stud
(2)
⁄Ω¢ - 20 ≈ ·Ω¡§
Stud
(2)
‹Ω• - 16 ≈ 1‡Ω¡§
Stud
⁄Ω™ - 13 ≈ 1
Stud
Cu-250A
Cu-400A
Cu-310A
Cu-400A
Cu-600A
•
•
•
•
•
•
•
•
—
•
-1
-1
-1
-1
-1
-2
-2
-2
-2
-2
-3
-3
-3
-3
-3
2/0 - #14Cu/#8Al
2/0 - #14Cu/#8Al
500MCM - #6Cu-Al
500MCM - #6Cu-Al
(2) 500MCM - #6Cu-Al
⁄Ω¢ - 20 ≈ ⁄Ω™
Stud
⁄Ω¢ - 20 Tapped hole
(2)
⁄Ω¢ - 20 ≈ 1
Stud
(1)
‹Ω• - 16 ≈ 1⁄Ω¢
Stud
(2)
‹Ω• - 16 ≈ 1fiΩ•
Stud
Al-175A
Al-175A
Al-380A
Al-380A
Al-760A
•
•
•
•
•
•
•
•
•
•
Connection
Line
Connector
Material and
Ampacity
CSA
U.L.
1-Pole
2-Pole
3-Pole
Load
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained
in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
When using the built-in Signal Tap Logic Analyzer of the QuartusII Web version , you need to enable the talkback function . Many friends who have just come into contact with the software may not be ab...
Now is a very good period, a very good opportunity. From our perspective, the entire computer industry has undergone several changes, and the PC has also undergone great changes. Internet computers ha...
Line 9 of this circuit is output to the input of the circuit through the microphone amplifier MAX9814, and line 5 is output. I would like to ask what the function of this circuit is and what the funct...
I wanted to learn embedded systems from scratch, so I bought a MINI2440 development board online. The shop owner said that a parallel port was needed for debugging, but my computer didn’t have one. Di...
The functions I want to achieve: 1. Phone operation (including making and answering calls) 2. SMS operation (including sending SMS, receiving new SMS, deleting a specified SMS, receiving the number of...
Traditional broadcasting systems generally need to be operated manually at a fixed time, and can only realize one-way broadcasting with few functions. Traditional bell ringing equipment has a singl...[Details]
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
1. Circuit composition
The whole circuit consists of two parts:
1. Power saving control circuit
As shown in the figure below. Including delay circuit and drive circuit.
(1) Delay ci...[Details]
1. Introduction
With the growth of parking demand, the scale of parking lots is becoming larger and larger. A lot of research has been done on intelligent parking lots in China, but most of th...[Details]
Converged processors meet scalability requirements
In current embedded system design, solutions based on MCU, DSP, FPGA and ASIC account for more than 90% of the market share. These solutions ...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
Introduction
X1226 has the functions of clock and calendar. The clock relies on hour, minute and second registers to track, and the calendar relies on date, week, month and year registers to tr...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
1 Introduction
Ultrasound refers to elastic vibration with a frequency higher than the audible frequency limit (i.e., in the frequency band above 20 kHz). The propagation process of this vib...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
introduction
At present, the research on micron and nanotechnology is very active, which has led to the rapid development of microtechnology and micro-mechanical electronic system (MEMS) t...[Details]
Cars equipped with xenon headlights are already common on the road. Whether they are standard equipment on high-end cars or embellishments on modified cars, xenon lamps are gradually becoming a sym...[Details]
In order to develop lighting LED technology, developed countries attach great importance to the research of LED testing methods and standards. For example, the National Institute of Standards and T...[Details]
With the explosive growth of electronic functions in cars, will more and more luxurious cars endanger the safety of passengers? This is the origin of the problem of over-electrification of cars. What ...[Details]