M Series Data Sheet
50 Watt DC-DC and AC-DC Converters
Features
• Extremly wide operating input voltage ranges from 8 to
385 VDC and 85 to 264 VAC, 47 to 440 Hz
• RoHS lead-solder exemption compliant
• Class I equipment
• Input over- and undervoltage lockout
• 1, 2, or 3 individually isolated and controlled outputs up
to 96 V
• Outputs: SELV, no load, overload, short-circuit proof,
rectangular current limiting characteristic
• Adjustable output voltages with remote on/off
• Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6
• Emissions according to EN 55011/55022
• All PCBs boards coated by protective lacquer
• Very high reliability
111
4.37"
3U
168
6.6"
• Battery charger models available
Safety-approved to IEC/EN 60950-1 and UL/CSA 60950-1
2
nd
Ed.
39
1.54"
8 TE
Description
The M Series of DC-DC and AC-DC converters represents a
broad and flexible range of power supplies for use in advanced
industrial electronic systems. Features include high efficiency,
reliability, low output voltage noise and excellent dynamic
response to load/line changes due to individual regulation of
each output.
The converter inputs are protected against surges and
transients occuring at the source lines. An input over- and
undervoltage lockout circuit disables the outputs, if the input
voltage is outside the specified range. An inrush current
limitation prevents circuit breakers and fuses from tripping at
switch-on.
All outputs are open- and short-circuit proof, and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to the
connector (pin 2). If the inhibit function is not used, pin 2 should
be connected to pin 23 to enable the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case, and output to
output isolation is provided. The converters are designed and
built according to the international safety standard
IEC/EN 60950-1 and UL/CSA 60950-1.
The case design allows operation at nominal load up to 71 °C
in a free-air ambient temperature. If forced cooling is provided,
the ambient temperature may exceed 71 °C but the case
temperature should remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which
disables the outputs, when the case temperature
T
C
exceeds
the limit. The outputs automatically recover, when the
temperature drops below the limit.
Various options are available to adapt the converters to
individual applications.
The converters may either be plugged into a 19" rack system
according to IEC 60927-3 or be mounted onto a chassis or a
plate.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) .................................. 14
Immunity to Environmental Conditions ................................ 16
Mechanical Data .................................................................. 17
Safety and Installation Instructions ...................................... 18
Description of Options ......................................................... 20
Accessories .......................................................................... 26
www.power-one.com
Description ............................................................................. 1
Model Selection ..................................................................... 2
Functional Description ........................................................... 5
Electrical Input Data ............................................................... 6
Electrical Output Data ............................................................ 8
Auxiliary Functions ............................................................... 11
BCD20018-G Rev AC, 09-Jan-2013
Page 1 of 26
®
M Series Data Sheet
50 Watt DC-DC and AC-DC Converters
than 1000 different types have been manufactured with
different input /output configurations and customized
specialities. Please consult Power-One for additional
information!
Model Selection
Non-standard input/output configurations or special custom
adaptions are available on request. Table 1 provides an
overview of the basic input and output configurations. More
Table 1a: Standard models AM, BM, FM
Output 1
V
o nom
I
o nom
[VDC] [A]
5.1
12
15
24
48
5.1
5.1
12
15
24
5.1
5.1
5.1
8.0
4.0
3.4
2.0
1.0
4.0
4.0
2.0
1.7
1.0
5.0
5.0
5.0
Output 2
V
o nom
I
o nom
[VDC] [A]
-
-
-
-
-
5.0
24
12
15
24
12
15
24
-
-
-
-
-
4.0
1.0
2.0
1.7
1.0
0.7
0.6
0.35
Output 3
V
nom
I
o nom
[VDC] [A]
-
-
-
-
-
-
-
-
-
-
12
15
24
-
-
-
-
-
-
-
-
-
-
0.7
0.6
0.35
Operating input voltage range and efficiency
V
i min
–
V
i max
8
–
35 VDC
AM1001-9R
AM1301-9R
AM1501-9R
AM1601-9R
AM1901-9R
-
-
AM2320-9
AM2540-9
-
AM3020-9
AM3040-9
-
η
min1
[%]
72
79
79
81
81
-
-
77
78
-
75
75
-
V
i min
–
V
i max
14
–
70 VDC
BM1001-9R
BM1301-9R
BM1501-9R
BM1601-9R
BM1901-9R
BM2001-9
BM2060-9
BM2320-9
BM2540-9
BM2660-9
BM3020-9
BM3040-9
BM3060-9
η
min1
[%]
74
80
81
83
83
-
-
79
80
-
76
76
-
V
i min
–
V
i max
20
–
100 VDC
FM1001-9R
FM1301-9R
FM1501-9R
FM1601-9R
FM1901-9R
-
-
FM2320-9
FM2540-9
--
FM3020-9
FM3040-9
-
η
min1
[%]
74
80
81
82
83
-
-
80
79
76
76
-
Options
-7,
P,
D0 – D9,
V0
–
V3
3
,
F,
A,
K,
H,
G
-7,
P,
D0 – D9
A,
K,
H,
G
-7,
P,
D0 – D9
K,
H, G
Table 1b: Standard models CM, DM, LM
Output 1
V
o nom
I
o nom
[VDC] [A]
5.1
12
15
24
48
5.1
5.1
12
15
24
5.1
5.1
5.1
1
2
3
4
Output 2
V
o nom
I
o nom
[VDC] [A]
-
-
-
-
-
5.0
24
12
15
24
12
15
24
-
-
-
-
-
4.0
1.0
2.0
1.7
1.0
0.7
0.6
0.35
Output 3
V
nom
I
o nom
[VDC] [A]
-
-
-
-
-
-
-
-
-
-
12
15
24
-
-
-
-
-
-
-
-
-
-
0.7
0.6
0.35
Operating input voltage range and efficiency
V
i min
–
V
i max
28
–
140 VDC
CM1001-9R
CM1301-9R
CM1501-9R
CM1601-9R
CM1901-9R
CM2001-9
CM2060-9
CM2320-9
CM2540-9
CM2660-9
CM3020-9
CM3040-9
CM3060-9
η
min1
[%]
74
80
82
82
82
-
-
79
80
-
76
76
76
V
i min
–
V
i max
44
–
220 VDC
DM1001-9R
DM1301-9R
DM1501-9R
DM1601-9R
DM1901-9R
DM2001-9
DM2060-9
DM2320-9
DM2540-9
DM2660-9
DM3020-9
DM3040-9
DM3060-9
η
min1
[%]
74
81
82
83
83
V
i min
–
V
i max
88
–
372 VDC
85
–
264 VAC
2
LM1001-9R
LM1301-9R
LM1501-9R
LM1601-9R
LM1901-9R
LM2001-9
LM2060-9
LM2320-9
LM2540-9
LM2660-9
LM3020-9
LM3040-9
LM3060-9
η
min1
[%]
73
79
78
81
81
-
-
77
78
73
71
-
Options
8.0
4.0
3.4
2.0
1.0
4.0
4.0
2.0
1.7
1.0
5.0
5.0
5.0
-7,
E
4
, P
D0
–
D9
V0
–
V3
3
A,
K,
H,
G
-7,
E
4
, P
D0 – D9
A,
K,
H,
G
-7,
E
4
, P
D0
–
D9
A,
K,
H, G
80
80
77
76
76
Min. efficiency at
V
i nom
and
I
o nom
. Typ. values are approx. 2% better.
Operating frequency range: 47 – 440 Hz; see
Safety and Installation Instructions
for > 60 Hz !
Option V0, V2, V3 available only for output 1 = 5.1 V (excludes option R)
Option E only available for CM and LM models (not for DM)
NFND: Not for new designs.
Preferred for new designs
BCD20018-G Rev AC, 09-Jan-2013
Page 2 of 26
www.power-one.com
®
M Series Data Sheet
50 Watt DC-DC and AC-DC Converters
Table 1c: EM and battery charger models
Output 1
V
o Bat
3
I
o nom
[VDC]
[A]
Same
V
o nom
and
I
o nom
as
DM models
12
24
36
48
60
1
2
3
4
Output 2
V
o max
[VDC]
-
-
-
14.15 – 14.6
28.3 – 29.15
42.45 – 43.72
56.6 – 58.3
70.75 – 72.87
V
o nom
[VDC]
I
o nom
[A]
Output 3
V
o nom
[VDC]
I
o nom
[A]
Operating input voltage range and efficiency
V
i min
–
V
i max
η
min 1
67
–
385 VDC [%]
EM1xxx-9R
EM2xxx-9R
EM3xxx-9R
-
-
-
-
-
-
-
-
-
-
-
-
-
V
i min
–
V
i max
η
min 1
88
–
372 VDC [%]
85
–
264 VAC
2
-
-
-
LM1781-9RD5
LM1782-9RD5
LM1783-9RD5
LM1784-9RD5
LM1785-9RD5
-
-
-
79
81
82
81
81
Options
V
o safe
4
[VDC]
-
-
-
12.84
25.68
38.52
51.36
64.2
-
-
-
-
same as DM models
-
-
same as DM models same as DM models
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-7,
E, D, A
G
-7,
E, A
G
3.6
1.8
1.2
0.9
0.72
Min. efficiency at
V
i nom
and
I
o nom
. Typ. values are approx. 2% better.
Operating frequency range: 47 – 440 Hz; see
Safety and Installation Instructions
for > 60 Hz
V
o nom
for EM models
Setting voltage with open R-input (battery chargers)
NFND: Not for new designs.
Preferred for new designs
BCD20018-G Rev AC, 09-Jan-2013
Page 3 of 26
www.power-one.com
®
M Series Data Sheet
50 Watt DC-DC and AC-DC Converters
Part Number Description
C M 2 5 40 -9 E P D3 A H
Operating input range
V
i
:
8 – 35 VDC
14 – 70 VDC
20 – 100 VDC
28 – 140 VDC
44 – 220 VDC
67 – 385 VDC
85 – 264 VAC, 88 – 372 VDC
................... A
................... B
................... F
................... C
................... D
................... E
................... L
Series ................................................................................... M
Number of outputs ........................................................ 1, 2, 3
Output 1,
V
o1 nom
:
5.1 V
12 V
15 V
24 V
other voltages
48 V
............ 0, 1, 2
.................... 3
................ 4, 5
.................... 6
................ 7, 8
.................... 9
Single-output models (different specs.) ...................... 01 – 99
Outputs 2, 3:
V
o2 nom
,
V
o3 nom
:
5.1 V ....................... 01 – 19
12 V ........................ 20 – 39
15 V ........................ 40 – 59
24 V ........................ 60 – 69
other voltages and specs. ............ 21 – 99
Ambient temperature range
T
A
: –25 to 71 °C .................. -7
– 40 to 71 °C .................. -9
customer-specific ... -0, -5, -6, -8
Auxiliary functions and options:
Inrush current limitation (CM, EM, LM) ........................ E
Output voltage control input (single-output models) .... R
2
Potentiometers for adjustment of output voltages ....... P
2
Save data signal (D0 – D9, to be specified) ................ D
1
ACFAIL signal (V0, V2, V3, to be specified) ................ V
1
Output voltage test sockets .......................................... A
Increased electric strength test voltage ....................... H
Input fuse built-in (not accessible) ............................... F
3
Coding strip at the connector ....................................... K
RoHS compliant for all 6 substances ........................... G
1
2
3
Option D excludes option V and vice versa
Feature R excludes option P and vice versa
Only for FM1000
NFND: Not for new designs
Preferred for new designs.
Note:
The sequence of options must follow the order above.
Example: CM2540-9EPD3AH:
DC-DC converter, operating input voltage range
28 – 140 VDC, providing output 1 with 15 V/1.7 A and
output 2 with 15 V /1.7 A; temperature range –40 to
+71 °C, inrush current limitation, equipped with
potentiometers, undervoltage monitor D3, test
sockets, and tested with higher voltage output to
case.
BCD20018-G Rev AC, 09-Jan-2013
Page 4 of 26
www.power-one.com
®
M Series Data Sheet
50 Watt DC-DC and AC-DC Converters
Functional Description
The input voltage is fed via an input fuse, an input filter, a
bridge rectifier, and an inrush current limiter to the input
capacitor. This capacitor sources a single-transistor forward
converter. Each output is powered by a separate secondary
winding of the main transformer. The resultant voltages are
rectified and their ripple smoothed by a power choke and an
output filter. The main control circuit senses the main output
voltage
V
o1
and generates, with respect to the maximum
admissible output currents, the control signal for the primary
switching transistor. This signal is transferred to the primary
side by a coupling transformer.
The auxiliary output voltages
V
o2
and
V
o3
are individually
regulated by means of secondary switching transistors. Each
auxiliary output's current is sensed using a current transformer.
If one of the outputs is driven into current limit, the other
outputs will reduce their output voltages as well, because all
output currents are controlled by the same main control circuit.
03009a
Option P
2
5
i
D, V
R
4
G
4
Main control circuit
14
17
C
Y
N
5
Vi+
29
Output 1
filter
20
23
Forward converter
approx. 70 kHz
1
2
C
Z
Control
circuit
output 2
5
14
Input filter
Output 2
filter
C
Z
L
5
Fuse
3
17
Vi–
32
Control
circuit
output 3
Output 3
filter
C
Y
8
11
26
1
2
3
4
5
Transient suppressor diode in AM, BM, CM, FM models.
Bridge rectifier in LM, series diode in EM models.
Inrush current limiter (NTC) in CM, DM, EM, LM models (option E: refer to the description of option E).
Single-output models with feature R.
LM-models
Fig. 1
Block diagram, triple-output models
BCD20018-G Rev AC, 09-Jan-2013
Page 5 of 26
www.power-one.com