AC-DC
70-150 Watts
DLG-HV Series
•
•
•
•
•
•
•
AC Input LED Driver
Constant Current Operation
High Power Factor
High Efficiency
Water Proof to IP67
xppower.com
90-305 VAC Input Voltage Range
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-305 VAC, see derating curve
• 47-63 Hz
• 70 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC,
100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC
Inrush Current
• 65 A at 230 VAC, cold start +25 °C
Power Factor
• >0.94 at 230 VAC, full load
Earth Leakage Current
• 750 µA max at 230 VAC
Input Protection
• DLG70/100 T2.0A/300V fuse fitted in line,
DLG150 T3.5A/300V fuse fitted in line
General
Efficiency
Isolation
• See table
• 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
• DLG50/70: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
• >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Switching Frequency
MTBF
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Operating Altitude
Vibration
•
•
•
•
•
-30 °C to +70 °C (see derating curve)
5-100% RH, non-condensing
-40 °C to +80 °C
3000 m
10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
Output
See table
No minimum load required
2 s max at 240 VAC
±0.5%
±5.0% of nominal output current
5% max
5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
Ripple & Noise
• DLG70: 700 mV
DLG100: 1000 mV
DLG150: 2000 mV (see note 2)
Overvoltage Protection
• 110-142%, recycle mains to reset
Overtemperature
• Unit shuts down, recycle mains to reset
Protection
Overload Protection
• 105% maximum, auto recovery
Short Circuit Protection
• Trip and restart (hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Output Voltage
Minimum Load
Start Up Delay
Line Regulation
Load Regulation
Turn On Overshoot
Transient Response
•
•
•
•
•
•
•
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55015, class B conducted and radiated
• EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
• EN61000-3-3
• EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria B
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, installation class 3,
Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria A
• EN61547, >95% 10 ms, 30% 200 ms, Perf
Criteria B, B for 70/100 W, A, A for 150 W
• EN61347, UL8750, CE Mark