Embedded Power for
Business-Critical Continuity
NFS110 Series
Single & Quad output
Rev. 11.2.09_69
NFS110 Series
1 of 5
Total Power:
80 - 110 W
Input Voltage:
85 - 264 Vac
120 - 370 Vdc
# of Outputs:
Single, quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and short circuit
protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011 conducted
emissions level B
• UL, VDE and CSA safety
approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Electrical Specifications
Output
Voltage adjustability:
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
LL to HL, FL
All outputs on all units
At turn-on
All outputs
Multi o/p 5.1 V only
5.1 V single output
12 V single output
15 V single output
24 V single output
Primary power limited
(See Note 13)
Burst mode operation
85 - 264 Vac
120 - 370 Vdc
47 - 440 Hz
230 Vac
110 Vac, 50 Hz
230 Vac, 50 Hz
35 A
0.2 mA, max.
0.4 mA, max.
3.0%
3.0%
12 - 14 V
15 - 18 V
24 - 30 V
±0.1% max.
0%
±0.02%/°C
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Pin max. 160 W
Pout min. 110 W
0A
Line regulation:
Overshoot/undershoot:
Temperature coefficient:
Overvoltage protection:
Output power limit:
Minimum output current:
Short circuit protection:
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
File No. 10401-3336-0213
• Licence No. 4001467 7
• UL1950 File No. E132002
• CSA C22.2 No. 950
File No. LR41062C
Input
Input voltage range:
Input frequency range:
Input surge current:
Safety ground leakage current:
All specifications are typical at nominal input, full load at 25
°
C unless otherwise stated
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
2 of 5
EMC Characteristics
Conducted emissions:
Radiated emissions:
ESD air:
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-3, level 3
EN61000-4-4, level 3
EN61000-4-5, level 3
EN61000-4-6, level 3
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 100 W
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
Input/output
Input/chassis
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
35 ms
17 ms
140 ms
100 ms
70% typical
70% typical
72% typical
75% typical
3000 Vac
1500 Vac
General Specifications
Hold-up time:
Efficiency:
Isolation voltage:
Approvals and standards:
(see note 12)
Weight:
MTBF (@25
ºC):
VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950
Singles
Multiple outputs
MIL-HDBK-217E
550 g (19.4 oz)
600 g (21.2 oz)
125,000 hours min.
Environmental Specifications
Thermal performance:
(See notes 9, 10)
Operating ambient
Non-operating
0 °C to 50 °C convection cooled
+50 °C to +70 °C, convection cooled
0 °C to +50 °C, 20 CFM forced air
+50 °C to +70 °C, 20CFM forced air
Relative humidity:
Altitude:
Vibration:
(See Note 11)
Non-condensing
Operating
Non-operating
5 - 500 Hz
0° C to +70 °C
-40 °C to +85 °C
80 W
Derate 2 W/°C
110 W
Derate 2.75 W/°C
5 to 95% RH
10,000 feet max.
40,000 feet max.
2.4 G rms peak
Peak, 0 °C to +50 °C, max. 60 seconds 110W
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
3 of 5
Ordering Information
Output
Voltage
+5.1 V
+12 V
–12 V
–5 V
+5.1 V (IA)
+24 V (IB)
(6)
+12 V
–12 V
+5.1 V
15 V
-15 V
-5 V
12 V
15 V
24 V
Output Currents
Max
(1)
8A
4.5 A
0.5 A
0.5 A
8A
3.5 A
4.5 A
0.5 A
8A
4A
0.5 A
0.5 A
7A
5A
3.5 A
Peak
(2)
20 A
9A
1.5 A
1.5 A
20 A
4.5 A
9A
1.5 A
20 A
7.5 A
1.5 A
1.5 A
9A
7.3 A
4.5 A
Fan
(3)
10 A
5A
1A
1A
10 A
4.5 A
5A
1A
10 A
5A
1A
1A
9A
7.3 A
4.5 A
Ripple
(4)
50 mV
120 mV
120 mV
50 mV
50 mV
240 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
120 mV
150 mV
240 mV
Total
Regulation
(5)
± 2.0%
± 3.0%
± 3.0%
± 3.0%
± 2.0%
+10/–5.0%
± 3.0%
± 3.0%
± 2.0%
± 4.0%
± 3.0%
± 3.0%
± 2.0%
± 2.0%
± 2.0%
NFS110-7612J
(7,8)
NFS110-7615J
(7,8)
NFS110-7624J
(7,8)
NFS110-7604PJ
(14)
NFS110-7602PJ
(6, 14)
Model Numbers
(13, 15, F)
NFS110-7601PJ
(14)
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: I
A
/ I
B
≤ 5, where:
I
A
= +5.1 V output current, and
I
B
= +24 V output current
The +24 V output will maintain ±5.0% regulation under the following
additional condition: I
A
≤ 5 A.
Single output models have floating outputs which may be referenced as
either positive or negative. Higher voltage supplies may be adjusted over a
wide output voltage range, as long as the total output power does not exceed
80 Watts (natural convection) or 110 Watts (forced air).
Power fail detect not available on single output models.
Derating curve is application specific for ambient temperatures >50 °C,
for optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, random vibration, 10 minute test for each axis.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Recommend a minimum load of 11 W to achieve the design MTBF. See the
derating curve on page 4.
Power failure detec is optional by including the suffix “P” to the model
number.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
NOTICE: Some models do not support all options. Please contact your
local Emerson Network Power representative or use the on-line model
number search tool at http://www.PowerConversion.com to find a suitable
alternative.
Transient Response
NFS110-7601PJ
+5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
+5.1 V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
+5.1 V (10 A to 20 A)
+12 V (4.5 A to 9 A)
+15 V (3.65 A to 7.3 A)
+24 V (2.25 A to 4.5 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
300 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
250 mV peak, 1 ms recovery
360 mV peak, 1 ms recovery
450 mV peak, 1 ms recovery
720 mV peak, 1 ms recovery
NFS110-7602PJ
NFS110-7604PJ
NFS110-7605J
NFS110-7612J:
NFS110-7615J
NFS110-7624J
Embedded Power for
Business-Critical Continuity
Rev. 11.2.09_69
NFS110 Series
4 of 5
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
AC (J1) mating connector
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478
or equivalent crimp terminals.
AC INPUT
4.75V
5V OUTPUT
HIGH
LOW
PFD SIGNAL
0-0.4 MAX
T1
0.475
0.010
(12.07)
Power fail detect signal (Note 8)
4.75V
DC (J2) mating connector
3.5V MIN
T3
T2
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478
or equivalent crimp terminals.
50ms ≤ T1 ≤ 200ms
T2 will vary with line and load
T3 ≥ 3ms
Pout: 110W
PFD output is an open collector which
will sink ≤ 40mA in the low state.
DERATING CURVE
(See Notes 9, 10)
1.80 (45.72) MAX
1.00 0.005
(25.4)
Output Power (Watts)
110W
0.050 0.020
(1.27)
3.35 0.015 (85.09)
1.55 0.005
(39.37)
Voltage Adjust
Optional
Power Fail
Detect Circuit
(Key = Pin 2)
6-32 UNC
(4PL)
PIN 1
20 CFM FORCED AIR COOLING
80W
J2
4.250
0.020
(107.95)
3.750
0.005
(95.25)
T1
T1
NATURAL
CONVECTION
COOLING
55W
40W
Pin 1
PIN 1
L1
J1
C6
F1
0.156
DIA. HOLE
(4PL)
11W
0W
0C
11W MINIMUM LOAD REQUIRED AT 230VAC
10C
20C
30C
40C
50C
60C
70C
0.250
0.010
(6.35)
0.250
0.010
(6.35)
5A, 250 VAC
6.50 0.005 (165.1)
7.00 0.020 (177.8)
Pin Connections
J1
Pin 1
Pin 2
Pin 3
J2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
-5 V
N/C = no connection
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+12 V
+12 V
PFD
-12 V
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+12 V
+12 V
PFD
-12 V
+24 V
+5.1 V
+5.1 V
+5.1 V
Return
Return
Return
Return
+15 V
+15 V
PFD
-15 V
-5 V
Vout
Vout
Vout
Return
Return
Return
Return
Vout
Vout
N/C
N/C
N/C
-7601PJ
AC Ground
AC Neutral
AC Line
-7602 P
AC Ground
AC Neutral
AC Line
-7604PJ
AC Ground
AC Neutral
AC Line
Singles
AC Ground
AC Neutral
AC Line
ALL DIMENSIONS IN INCHES (mm)
Mechanical Notes:
A
Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes
without effecting safety approval.
B
The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to
the system chassis.
C
The heat sink is grounded, and allows system grounding by mechanical connection to the system
chassis.
D
The supply must be mechanically supported using the PCB mounting holes and may be additionally
supported by the heatsink mounting holes.
E
It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a
chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures
will improve power supply lifetime.
F
A standard L-bracket and cover is available for mounting which contains all screws, connectors and
necessary mounting hardware. The kit is available, order part number “NFS110CJ”.
Removed for Key
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 11.2.09_69
NFS110 Series
5 of 5
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2009 Emerson Electric Co.