Control Switches and Signaling Devices, 22.5mm Plastic Series
This range of 22.5mm plastic series pushbuttons, selector switches, illuminated switches and pilot lights have been designed to provide the following
features:
• Economy of space
• Self wiping contacts
• Safe in operation
• Simple to mount (only need a screw driver)
• Mounting method is unaffected
by excessive vibration
• Electric shock protection (grounded unit)
• Aesthetically pleasing
• Heavy-duty construction
• Shrouded terminals
• Very good flame resistance
• Use of LEDs for long life
Actuators
The circular actuators have black plastic bezels and are functionally interchangeable on the different contact elements.
Contact elements
The contact elements are double break and have self-wiping contacts. The elements are
interchangeable and can be stacked without additional hardware. 1 to 6 elements (NO or NC)
can be used for non-illuminated actuators, whereas, 1 to 4 elements (NO or NC) can be used
for illuminated actuators. Gold NO or NC contact elements for low voltage, low current, < 25mA,
switching applications are available.
42x30
43
24
24
Illuminated pushbuttons and pilot lights
Pilot lights and pushbutton switches are suitable for direct connection through a series resistor, series resistor and diode, using bayonet cap filament
bulb type BA9s as follows:
Supply voltage for direct connection without series resistor . . . . 6V - 130V
Supply voltage through series resistor . . . . . . . . . . . . . . . . . . . . 12V - 415V
Supply voltage through resistor and diode . . . . . . . . . . . . . . . . . 230 VAC
Pilot lights and illuminated actuators are available with integral LEDs, suitable for operating at various voltages; 6V, 12V, 24V, 30V, 48V, 63.3V, 110V,
125V, 230VAC or DC and 415VAC. Pilot lights and illuminated actuators are available with LED bulbs (bayonet cap, BA9s design with OAL max. 28mm)
suitable for operating at various voltages; 24V, 110V and 230V. On request an extra short circuit protection consisting of built-in fuse in the LED modules
can be provided. Pilot lights are available with built -in transformers suitable for operating at 110VAC, 230VAC input and 6V, 12V and 24V output.
Terminals
Contact elements and pilot lights are designed to have shrouded terminals with combination screws.
Mounting
The plastic series control devices 22.5mm can be mounted in any position
on panels of 1 to 5 mm thickness. We recommend minmum mounting centers
of 30mm x 40mm. However, the dimensions and configuration should be
decided on the basis of the application. The actuators and the lens
assemblies lock on the holding bracket. See assembly details.
Electrical and mechanical characteristics
Environment
Standards conformity:
CSA - C22.2 No. 14-95, UL508, EN60947-5-1 2000
Approvals:
CSA - C22.2 No. 14-95, UL508, VDE0660
Degree of protection:
IP 65 as per IEC529, NEMA 4X, 12 as per UL50
Ambient temperature:
-25°C to +70°C
Operating position:
All positions
Contact block
Rated insulationvoltage:
Rated thermal current:
Contact operation:
Make and break capacity
as per IEC 947-5-(1) 1990:
500V
10A
Self wiping, slow break NO or NC
AC 15 - 4A, 415VAC
DC 13 - 0.5A, 110VDC
Minimum 1 X 0.5mm
2
, minimum 2 x 15mm
2
, or 1 x 2.5mm
2
1-2 for NC, 3-4 for NO
10A cartridge fuse, HRC type, rated for resistive loading
Over one million operations
V
AC15
A
4
3
2
Modules for pilot lights and illuminated switches with integral LED / LED bulb (BA9S cap)
Current consumption (applicatable to all colors)
24VAC/DC, 110VAC and 240VAC:
110VDC:
220VDC:
Service life (at nominial voltage and at ambient temperature):
Voltage limits (nominal voltage):
Short circuit protection:
300
Terminal capacity:
max. 20mA
max. 15mA
max. 10mA
100,000 hours
<20% of rated voltage>
on specific request
min. 1 X 0.5mm
2
, max. 2 x 1.5mm
2
or 1 x 2.5mm
2
24
120
230
DC13
A
0.5
0.2
V
24
110
Bracket mounting
Click
Control Switches and Signaling Devices
Ø 22.5 DIN
Click
30
40
Screwdriver
Scre
wdriv
er
Bracket removal
Terminal capacity:
Terminals marking:
Short circuit protection:
Mechanical life:
Electrical rating
(one million operating cycles at 3600 cycles per hour, load factor 0.5)
Control Switches and Signaling Devices, 22.5mm Plastic Series
Ordering Information
1. Actuators, illuminated actuators, contact elements, lens assemblies and pilot lights are each ordered separately. For complete assemblies, please
contact the factory for specific part numbers.
2. Prefix ASP2 for all actuators indicates 22.5 plastic series
3. The type numbers of contact elements are:
NO
NC
4. Part number examples:
Actuator
Pilot light
Actuator mounting
Individual mounting
Actuator mounting
Individual mounting
S1, S3
S5, S7
S2, S4
S6, S8
Note: S3, S4, S7, and S8 have gold plated
contact suitable for low voltage, low current
applications <25mA
= flush actuator, green
= pilot light without series resistor, red
ASP2AF3
ASP2PLB4
Accessories and spares
Legend plates
Legend plates 30 x 40 mm are supplied with the following standard text:
STOP
DOWN
CLOSE
HAND
FAST
INCH
OFF
LEFT
REVERSE
POWER ON
Replacement bulbs
Filament Bulb type ABA9S, OAL 28mm
Voltage: 6
12
24
30
Watts:
1
2
2
2
LED bulb type BA9S, OAL 28mm
Color:
White
Green
P/N:
AMCB9124 AMCB9324
AMCB91110 AMCB93110
AMCB91230 AMCB93230
Lenses
Lens color:
White
For pilot lights
w/filament bulb
For illuminated
actuators
w/filament bulb
For pilot lights
w/ LED
For illuminated
actuators w/LED
48
2
60
2
130
2.6
Blue
AMCB9624
AMCB96110
AMCB96230
Yellow
AMCB9824
AMCB98110
AMCB98230
V
24
110
230
W
0.5
1.0
1.0
EM
START
UP
OPEN
AUTO
SLOW
RESET
ON
RIGHT
FORWARD
TRIP
G
ER
E
STOP
Red
AMCB9424
AMCB94110
AMCB94230
Amber
AMCB9524
AMCB95110
AMCB95230
Translucent Green
AP2PLL1
AP2LAL1
AP2PLL3
AP2LAL3
Red
AP2PLL4
AP2LAL4
Amber
AP2PLL5
AP2LAL5
Blue
AP2PLL6
AP2LAL6
Clear
AP2PLL7
AP2LAL7
Yellow
AP2PLL8
AP2LAL8
AP2PLL1L AP2PLL3L AP2PLL4L
AP2LAL1L AP2LAL3L AP2LAL4L
AP2PLL5L
AP2LAL5L
AP2PLL6L
AP2LAL6L
22.5
AP2PLL7L
AP2LAL7L
AP2PLL8L
AP2LAL8L
22.5
22.5
30.5
Adaptor
For mounting 22.5mm devices into 30.5mm cutout
Part number:
A2ADP
Mounting Bracket:
Padlock
Mushroom actuator:
Projecting actuator:
Boot
For non-illuminated
flush actuator
For twin actuator
AP2BRK
A2PAM
A2PAP
22.5
30.5
22.5
30.5
22.5
22.5
30.5
22.5
30.5
22.5
30.5
30.5
30.5
30.5
A2BT7
A2ATBT7
For flush/projecting A2ALBT7
illuminated actuator
For twin
illuminated actuator
Hole plug
22.5mm, black
A2ATLBT7
Bulb extractor
A2BA9SE
A2BP2
301
Control Switches and Signaling Devices
Y
NC
Non-Illuminated Operators, 22.5mm Plastic Series
Operator
Type
Flush
Flush
Booted
Projecting
Mushroom
40mm
with Key
Airpax device, plastic, 22.5mm
A S P 2 A F 4 B T 7
Control Switches and Signaling Devices
Note:
Mounting bracket is included.
However, see tables 1 & 2 to order
contact elements separately
1
Part Type
Component
Code
A
Decision 5 is required only when a “Selector”
type actuator is selected from decision 2.
5
Key Selector Functions
Key Removal
Code
Left Center Right
Maintained
√
√
√
√
√
√
√
√
√
√
√
√
√
√
2PB
2PO
2PI
2POSR
3PB
3PA
3PC
3PSR
3PSRL
3PSRR
Code
2P
2PSR
3P
3PSR
3PSRL
3PSRR
2
Operator Type
Code
Flush
F
Flush - booted*
F
Projecting
P
Mushroom - 40mm with key
MLKB
Mushroom - 40mm spring return
M
Mushroom - 40mm push/pull
MPP
Mushroom - 40mm latching
ML
w/arrow indicator
Mushroom - 30mm latching
MLS
w/arrow indicator
Mushroom - 40mm latching
MLT
trigger w/arrow indicator
Mushroom - 40mm latching
MLTKB
trigger w/key
Jumbo mushroom - 60mm
MJ
spring return
Jumbo mushroom - 60mm
MJPP
push/pull
Jumbo mushroom 60mm
MLJ
latching w/arrow indicator
Selector w/key**
‡
K
‡
Selector**
S
Extended selector**
†‡
S
††
Twin
T
*
**
†
††
Must select BT7 from decision 4
Selector available in black only
Must select E from decision 4
Please select flush or projecting, available in standard
green/red color combination
Must select an option from decision 5
Maintained
3
Operator Color
Code
White
1
Black*
2
Green
3
Red
4
Amber
5
Blue
6
Yellow
8
*
Selector is available in black only
Maintained
Spring return
Maintained
Maintained
Maintained
Spring return
Spring return
Spring return
Selector & Extended Selector Functions
Maintained
4
Options (see note)
Booted
(flush actuator only)
Extended
(selector actuator only)
Code
BT7
E
Spring return
Spring return
Spring return
Spring return
Maintained
302
‡
Note:
Except for Selector types or a flush
boot option, your order number is complete
after decision 3. However, if a Selector type is
required, please continue with the remaining
decisions. If a flush boot is required your part
number is complete after decision 4
See Accessories for marking legend plates. If required, please contact factory for actuator marking.
Non-Illuminated Operators, 22.5mm Plastic Series
Mushroom 40mm
Spring
Return
Push
Pull
Latching
w/ Arrow
Indicator
Mushroom 40mm
Mushroom
30mm Latching Latching trigger type
with arrow
indicator
With
Arrow
Indicator
Jumbo Mushroom 60mm
With Key
Spring
Return
Push
Pull
Latching
w/ Arrow
Indicator
Operator
Type
Selector
with Key
Selector
Extended
Selector
Twin
Note:
Up to six contact elements can
be installed on any non-illuminated
operator
Up to four contact elements
can be installed on any illuminated
operator
Table 1:
Contact
Element
1NO
Actuator
Mounting
S1
Figure
Number
1
1
2 or 3
2 or 3
Gold
Contacts Diagram
Table 2: Contact element assembly variations for non-illuminated and illuminated
pushbuttons. NO is supplied in green and NC is supplied in red. Order elements with
P/N’s S1 for (NO), S2 for (NC), S3 for (NO, gold contacts), etc. Contact elements S5,
S6, S7 and S8 have the mounting screw reversed (see fig. 6 &7) for mounting to a
back panel or wall and cannot be ordered as a complete assembly.
Contact Elements
1NC
S2
1NO+1NC S1+S2
2NO
S1+S1
2NC
S2+S2
2 or 3
2NO+2NC S1+S1
4
S2+S2
3NO+3NC S1+S1+S1 5
1NO
1NC
S2+S2+S2
S3
1
S4
1
⊗
⊗
L or R
Fig 1
L
or
R
Fig 2
L or R
Fig 3
L
or
R
Fig 4
L
or
R
Fig 5
L or R
Fig
303
6
See Accessories for marking legend plates. If required, please contact factory for actuator marking.
/*Signal definition: clk: clock signal, in this example, its frequency is 1Hz; decide: signal fed back by the telephone company, representing the type of call, "01" means local call, "10" means long-d...
Universal Serial Bus or “USB” has been around for a long time; originally USB devices were divided into master and slave devices: data was transferred from the master device such as a computer, and da...
1. Graduated from an ordinary university with a bachelor's degree in computer science, with excellent grades during school 2. Worked in a formal private enterprise for VOIP R&D (ARM Linux driver and a...
It has been a long time since I received the PSoC 4 tool. It is not easy to receive this kit. I waited for a long time, until the flowers really withered, the kit came. I opened the box and it was rea...
It is said to be a high-speed circuit. At present, it seems that the theory is also common for high-speed signals. In short, you will find that the knowledge points are mutual. Without further ado, he...
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
1. What is temperature?
Heat is a type of molecular motion. The hotter an object is, the faster its molecules move. Absolute zero is defined as the temperature at which all molecular motion ...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
To understand how and why OLED power supply affects display image quality, you must first understand OLED display technology and power supply requirements. This article will explain the latest OLED...[Details]
introduction
Incandescent bulbs can emit a variety of light, but in specific applications, only green, red, and yellow light are usually needed - such as traffic lights. If an incand...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]